검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4,611

        286.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the present work, Inconel 718 alloy is additively manufactured on the Ti-6Al-4V alloy, and a functionally graded material is built between Inconel 718 and Ti-6Al-4V alloys. The vanadium interlayer is applied to prevent the formation of detrimental intermetallic compounds between Ti-6Al-4V and Inconel 718 by direct joining. The additive manufacturing of Inconel 718 alloy is performed by changing the laser power and scan speed. The microstructures of the joint interface are characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, and micro X-ray diffraction. Additive manufacturing is successfully performed by changing the energy input. The micro Vickers hardness of the additive manufactured Inconel 718 dramatically increased owing to the presence of the Cr-oxide phase, which is formed by the difference in energy input.
        4,000원
        287.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 2020년 1월부터 10월까지 향신식물 114건을 수거하여 잔류농약 실태조사를 실시하였다. GC-MSMS, GC-ECD, GC-NPD, LC-MSMS, LC-PDA, LC-CAS를 이 용하여 다종농약 다성분분석법으로 잔류농약 341종을 분석하였다. 조사 결과 36건의 검출이 있었으며 검출률은 31.6%이었다. 이 중 7건은 농약 잔류허용기준을 초과하였으며 부적합률은 6.1%이었다. 농약 잔류허용기준을 초과한 품목은 고수(2건), 민트(2건), 바질(1건), 로즈마리(1건), 서양자초(1건)이었다. 잔류농약 341종을 분석한 결과 22종의 농약 성분이 52회 검출되었고 농약 잔류허용기준을 초 과한 성분은 8종이었다. 농약 잔류허용기준을 초과한 성분은 etofenprox, flufenoxuron, fluquinconazole, iprodione, lufenuron, paclobutrazol, phenthoate, spiromesifen 이었다.
        4,000원
        288.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Oxide dispersion-strengthened (ODS) steel has excellent high-temperature properties, corrosion resistance, and oxidation resistance, and is expected to be applicable in various fields. Recently, various studies on mechanical alloying (MA) have been conducted for the dispersion of oxide particles in ODS steel with a high number density. In this study, ODS steel is manufactured by introducing a complex milling process in which planetary ball milling, cryogenic ball milling, and drum ball milling are sequentially performed, and the microstructure and high-temperature mechanical properties of the ODS steel are investigated. The microstructure observation revealed that the structure is stretched in the extrusion direction, even after the heat treatment. In addition, transmission electron microscopy (TEM) analysis confirmed the presence of oxide particles in the range of 5 to 10 nm. As a result of the room-temperature and high-temperature compression tests, the yield strengths were measured as 1430, 1388, 418, and 163 MPa at 25, 500, 700, and 900oC, respectively. Based on these results, the correlation between the microstructure and mechanical properties of ODS steel manufactured using the composite milling process is also discussed.
        4,000원
        296.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Subway trains with air cleaners have been newly deployed in the Seoul Metro system. The purpose of this study was to determine differences regarding in-cabin particulate matter with respect to concentrations less than 10 um (PM10) and 2.5 um (PM2.5) through the operation of air cleaners in subway trains. One subway train newly installed with in-cabin air cleaners on Seoul Metro Line number 2 was chosen monitoring in 2020. In-cabin air cleaners were turned-on at both front and back areas while those in the middle area were turned-off while the train was running. In-cabin PM10 and PM2.5 concentrations were measured in each area using a real-time aerosol monitor. Average in-cabin PM10 concentrations were statistically significantly lower (by 15%) in areas with air cleaners turned-on (43.8±12.1 μg/m3) compared to those areas where the air cleaners were turned-off (51.4±15.0 μg/m3). Average incabin PM2.5 concentrations were significantly lower (by 14%) in areas with air cleaners turned on (33.7±12.2 μg/m3) compared to those areas where air cleaners were turned-off (39.2± 14.4 μg/m3). In-cabin PM10 and PM2.5 concentrations ratios were similar regardless of area with air cleaners turned-on or turned-off. The in-cabin PM10 and PM2.5 concentrations were not associated with commute time. Use of air cleaners in subway trains effected reductions in in-cabin PM10 and PM2.5 concentrations.
        4,000원
        297.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the demand for the monitoring of VOCs increases, various unpowered colorimetric sensors are being developed, but the performance evaluation method of the developed sensors has not been systematically established. In this study, the device, experimental process, and data calculation methods for the performance evaluation of the colorimetric sensors were proposed. An aluminum chamber (70W× 128 L × 40 mm H) was designed to expose the sensor to a constant concentration of VOCs. In addition, an experimental apparatus was devised to evaluate the effect of environmental factors (temperature and humidity) affecting the ability of the sensor to detect VOCs. To calculate the color change value of the sensor corresponding to the concentration of VOCs, the ‘peak wavelength method’ that analyzes the wavelength of the highest intensity for high-concentration VOCs and the ‘spectral centroid method’ using a weighted arithmetic average for low-concentration VOCs were used. As a result of evaluating the ability of the colorimetric sensor to detect VOCs, which was made of polydimethylsiloxane (PMDS) by the method proposed in this study, the wavelength change values (bandgap shift) of the sensor for 1,000 ppm of benzene, toluene, oxylene, and acetone were 0.898 nm, 2.304 nm, 5.775 nm, and 0.249 nm, respectively. The precision was calculated by repeatedly measuring the sensing ability of the sensor 5 times for each type of VOCs. The precision of the sensor responses to benzene, toluene, o-xylene, and acetone were 15.23%, 7.84%, 4.14%, and 30.00% RSD, respectively. The method proposed in this study can be used to evaluate the performance of various types of VOCs colorimetric sensors.
        4,200원
        298.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 국내 참나무 생육지에서 채집된 송로버섯의 일종인 T. himalayense 자실체 추출물(TH)의 항염증 활성을 확인하였다. LPS로 유도된 RAW 264.7 대식세포를 대상으로 한 염증 억제 실험에서 TH는 100 μg/ml 이하의 농도에서 세포독성을 보이지 않았으며 LPS에 의해 증가된 NO와 PGE2의 생성을 농도 의존적으로 억제하였다. Western blot 분석 결과로 볼 때, TH의 항염증 활성은 iNOS와 COX-2 유전자의 발현억제에 의해 NO와 PGE2 의 생성이 감소된 것으로부터 유발된 것임을 입증한다. 또한, TH가 대식세포에 의해 생산 및 분비되는 cytokine IL-1β와 IL-6의 생성을 효과적으로 저해함을 확인하였다. T. himalayense는 다양한 염증 매개체들의 과발현을 효과적으로 억제하며, 이를 표적으로 하는 항염증 관련 식품 및 의약품에 다양하게 활용 될 수 있을 것으로 기대된다. 추후 염증 예방 물질로 적용 될 수 있는 가능성을 높이기 위하여 염증성 작용 기전에 대한 자세한 연구가 필요할 것으로 사료된다.
        4,000원
        299.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        원형질체 융합 기술은 종·속간 유전적 한계를 넘어 육종과 그 소재로 활용하고데 목적이 있다. 본 연구에서는 ‘흑타리’(P. ostreatus)와 ‘호산’(P. pulmonarius)의 단핵균사를 이용하여 원형질체를 나출하고 나출된 원형질체를 융합하여 종간 교배 계통을 육성하였다. 육성계통의 균사생장속도는 ‘호산’, ‘흑타리’, PF160313, PF160306 계통 순으로 빠른 편이었다. 균사 밀도는 PF160306 계통이 가장 높았고, 나머지는 중간 수준의 밀도를 나타내었다. 원형질체 융합계통인 PF160306과 PF160313 계통은 ‘흑타리’ 품종 보다 배양 기간이 10일, ‘호산’ 품종보다 2일 단축되었다. 자실체 생장 기간은 ‘흑타리’와 ‘호산에 비하여 각각 3일, 1일 단축되었다. PF160306 계통의 생산량은 135.9 g/병으로 ‘호산’에 비하여 높았으나 통계적으로 유의차가 없었다. 자실체 발생기간은 15˚C에서 9일, 25˚C에서 4.5일로 온도가 높아짐에 빨라졌다. 자실체의 갓색은 21 o C 노란색이 가장 선명하게 발현되었다. URP primer 7을 사용하여 PCR 밴드 패턴을 비교하였을 때, 전체적으로 ‘호산’ 품종과 유사하였다. DPPH radical 소거능과 폴리페놀 함량에 있어 ‘순정’은 각각 62.5%, 43.5 mg/mL였으며, PF160313 계통은 각각 65.7%, 49.9 mg/mL를 나타내어 계통간 유의차가 있었다. ACE 활성은 ‘순정’ 74%, PF160313 계통 75%로 유사한 수준이었다.
        4,000원
        300.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 코로나-19(COVID-19)로 인해 원격근무의 중요성이 강조되고 있는 상황에서 본 연구는 원격근무 상황에서 자기효능감의 역할에 대해 살펴보았다. Bandura(1986)의 자기효능감에 영향을 주는 4대 요인과 Staples et al.(1999)의 가상조직 기반에서의 자기효능감의 선행요인에 관한 연구를 활용하여 연구모형을 설정하였으며, 자기효능감의 선행 변수로는 원격근무에 대한 직접경험, 상사의 원격근무 관찰 경험, IT 변화 두려움, 상사의 코칭을 설정하였다. 또한, 상사의 코칭을 통한 언어적 설득이 자기효능감에 영향을 주는 과정에서 상사 신뢰의 조절효과에 대하여 검증을 하고자 하였다. 본 연구의 목적을 달성하기 위하여 원격근무 경험이 있는 근로자 463명의 설문응답 결과를 분석 자료로 활용하였다. 연구 결과는 원격근무에 대한 직접경험과 상사의 코칭을 통한 언어적 설득은 자기효능감을 높이는 정(+)의 영향을, IT 변화 두려움은 자기효능감을 낮추는 부(-)의 영향을 미치는 것을 확인하였다. 그리고 상사 신뢰가 높은 집단은 상사 신뢰가 낮은 집단에 비하여 상사의 코칭이 자기효능감에 미치는 효과가 더 강한 것으로 확인되었다. 본 연구는 4차 산업 환경과 코로나-19의 시대적 상황을 반영한 원격근무와 자기효능감에 대한 연구를 통하여 원격근무에 대한 직접 경험이 자기효능감에 영향을 주는 주요한 변수임을 확인하였다.
        6,700원