검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 823

        381.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The apparel industry has recently been recognizing the important target market of middle-aged women. The aim of this study was to examine the anthropometric characteristics of US women of 46 to 65 years of age and identify distinctive body shape characteristics of US middle-aged women. A total of 1915 middle-aged women whose ages ranged from 46 to 65 were selected from the SizeUSA database. The age range was divided into two groups: 46-55 and 56-65. Twenty-four body measurements important for apparel development were chosen. Four factors—Girth Factor, Height Factor, Hip Drop Factor, and Bust Drop Factor—accounted for the US middle-aged women’s body measurements. The body shapes were classified into four body shapes, which were Y-Shape in the overweight range, S-Shape in the overweight range, H-Shape in the overweight range, and the A-Shape in obese range. H-Shape, which was the least-defined waist in relation to the bust and hips with a short height, existed more in older middle-aged women than in younger middle-aged women. Y-Shape, S-Shape, and A-Shape existed more in the group of younger middle-aged women than in the group of older middle-aged women. In addition, compared with the younger middle-aged women, older middle-aged women had narrower shoulders, a larger waist, thinner legs, and a longer distance between side neck to bust point. The findings from the current study may be applied in the apparel industry for developing clothing sizing systems for US middle-aged women.
        4,200원
        382.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to develop slacks patterns for obese-schoolgirls aged 10~12 by using a 3D virtual garment simulation system. The criteria for subjects in this study were girls who had a BMI of over 25kg/m2. A total of 155 schoolgirls who met these criteria were enrolled. The results were as follows: First, by using 3D virtual garment simulation, a new slacks pattern considerate of obese-schoolgirls was developed. The basic numerical formulae were as follows: Front and back hip girth of H/4-0.5+1 and H/4+0.5+1.5, front waist girth of W/4+1+0.5, back waist girth of W/4+2+0.5, front crotch extension of H/16-0.5, back crotch extension of H/8-0.5, front dart amount of 1, and back dart amount of 2. Second, according to the new slacks pattern appearance evaluation, the new slacks pattern scored more highly than the existing pattern for silhouette and ease amount, confirming that the new slacks pattern is appropriate for obese-schoolgirls. Additionally, the new slacks pattern was evaluated allowing for the proper space length of the waist, abdomen and hips. This study is expected to serve as important basic data for ensuing studies that may utilize a 3D virtual garment simulation system with 2D patterns and for future 3D pattern production program development.
        4,300원
        383.
        2015.06 구독 인증기관·개인회원 무료
        Measuring body size with a 3D scanner can reduce inter-measurer variability and provide better accuracy compared to using a traditional methods of measurement (Park, Nam, & Park, 2009). Many size measurement projects (or studies) that measure body size established a size measurement method prior to the development of a 3D scanner and automatic size measurement programs that produce 3D virtual body size measurements (Park, &Nam, 2012). Size data measured through an automatic size measurement program are more accurate and have a lower variability that is more appropriate for body measurements (Han, & Nam, 2004; Nam, Choi, Jung, & Yun, 2004). However, this method is limited to healthy subjects who can maintain a correct posture in a 3D scanner. It is difficult for the elderly to maintain the correct posture for body measurements in ‘Basic Human Body Measurements for Technological Design’ of ISO 7250(1997). Body measurement definitions are based on vertical and horizontal directions consequently, it is hard to measure those with a bent body type even if they stand in a correct posture. Most body measurement items are automatically measured in vertical and horizontal directions because current automatic size measurement programs utilize algorithms based on typical body measurement definitions. The size measurement method based on a vertical and horizontal directions tends to have a problem for elderly individuals with a bent body type who have difficulty maintaining a correct posture for 3D scanning as defined in ISO 7250(1997)(Ashdown, & Na, 2008).This study analyzes the problem of present auto-measurement programs that use elderly’s 3D body scan data. We conducted a comparative analysis of elderly’s body sizes using an auto-measurement program from virtual 3D body scan data and direct measurement with traditional measurement methods. We establish 34 typical body size measurements for the use of data from 464 males and 472 females (total 936) between the ages of 70 to 85. For error analysis, data separated to normal values and outliers compared with ISO 20655(2003). ISO 20685 defines the accuracy of extracted measurements by classification and measurement type (segment lengths, body height/breaths/depth, large/small circumferences, and head/hand/foot dimensions). The majority of outliers for the male and female body height type was “height”. Total number of persons with outliers for Height’s data was 603; consequently, 64.4% of subjects (elderly group of 70-85 yrs.) could not maintain a correct posture when scanning. Other data also had many errors from inaccurate measurement postures. A total of 72.3% of males and 70% of females have incorrect values in small circumferences. The segment lengths’ error data was 76.5% of males and 75% of females; in addition, the head dimension’ outliers were 87% for both male and female subjects. Especially 57.46% of males had incorrect data, while 74.67% of females had a type of large circumference. Female chest circumference had significant errors due to sagging breasts. The differences identify with a correlation between type of large circumference (chest, hip, under bust, waist, waist of omphalion) and gender. There were several correlations between the many measurement errors because values over 70% of data have outliers; however, each measurement type has properties in regards to correlation. A substantial positive correlation was found between all measurements (except hip circumference) in the type of large circumference; in addition, one-way ANOVA indicated that the measurements influenced height and were statistically significant. Outliers found in height data for the elderly’s were more likely to have errors in the type of large circumference. The type of body height indicated a strong correlation and statistical significance between the axilla height and other measurements (height, waist, crotch, lateral malleolus). Axilla height with more outliers indicated that other type of body height measurements had a higher potential for errors. The posture for body measurement was standardized as standing erect; however, this study indicated that many measurement errors were possible between using an auto-measurement program and direct measurement. The value of outlier about a particular measurement item can expect increased errors about any group (height: large circumference group/ axilla height: body height group). We have to study the relation in measurements in these types ‘large circumference’ because ‘head dimensions’ types correlate between measurements in each group. We need a more detailed analysis about outliers to find the major factors for measurement errors in regards to the elderly as well as discuss the possibility of ISO measurement-standard’s application for the elderly.
        384.
        2015.06 구독 인증기관·개인회원 무료
        With the recent hype concerning three-dimensional (3D) printing technology, affordable 3D printers have been launched, enabling individual machine owners to download or create design files and thus produce artifacts. As a design community, Shapeways—which comprises over 300,000 members and 25,000 online shops—commercializes and promotes good ideas using 3D printing technology (Shapeways, 2015). Through Thingiverse, people can globally upload and share design modeling files without cost and print out items as desired. In general, 3D printing communities provide data without charges and witness gradually increasing data sharing rates. Literature on 3D printing mainly focuses on cases of technology-related patents, policies, and intellectual property rights. Thus, there is a paucity of empirical studies on 3D printing users. To overcome the limitations of previous studies, this study first builds on both social cognitive and social capital theories to elucidate the effects of 3D printing community users’ self-efficacy; altruistic tendency; and perceived structural, cognitive, and relational capital on their voluntary knowledge sharing and innovative behaviors. Second, it aims to verify inter-group differences in innovative behaviors of 3D printing community users while considering either high or low levels of fashion innovativeness and fashion involvement. For this verification, antecedents of knowledge sharing are elicited from previous research followed by an interview and a questionnaire survey with 3D printing community users to substantiate such antecedents. Next, the data collected from the interview and survey is analyzed using SPSS 18.0. The results indicate that first, altruistic tendencies influence knowledge sharing, which is consistent with the social cognitive theory, whereas structural, cognitive, and relational capitals affect knowledge sharing, which parallels social capital theory. Second, knowledge sharing in 3D printing virtual communities exerts significant effects on innovative behaviors. This study establishes the antecedents and consequences of knowledge sharing in 3D printing virtual communities and proposes a model for effective knowledge sharing, which is projected to stimulate the application of 3D printing technology in creating and sharing fashion design content and providing substantive data for market formation.
        385.
        2015.06 구독 인증기관 무료, 개인회원 유료
        The aim of this study is to understand how companies radically change their approach to marketing after the introduction of a process innovation. Thanks to multiple case studies in Arezzo gold luxury district, it is possible to build a conceptual framework subsequently tested through System Dynamics simulation technique.
        3,000원
        386.
        2015.05 구독 인증기관 무료, 개인회원 유료
        1930년대 초 뤼미에르 형제가 그들의 <열차의 도착>을 3D 입체영화로 다시 촬영한 이래 영화의 역사를 살펴보면 <브와나 데블>(1952)등이 만들어진 1960년대의 산업적으로 크게 성공을 거둔 황금기와 <죠스3>(1983)등이 만들어진 1980년대를 거쳐 2009년 <아바타>(2009)의 성공 이후 3D 영화 제작은 지금까지 이어져 오고 있다. 국내에서도 발 빠르게 <나탈리>(2010)와 <7광구>(2011)가 제작되었으나 작품성과 흥행 모두에서 참담한 실패를 겪는다. 이후 3D 입체영화 제작에 대한 부정적인 시선과 불신이 팽배해지게 되고 여러 작품들의 제작이 중단되는 결과를 가져오게 된다. 영화 <미스터 고>(2013)는 오랜 준비 기간을 거쳐 고릴라의 털을 사실적인 CG로 만드는 기술을 개발하고 3D 촬영 카메라를 직접 구입해 우리나라 영화 제작 환경에 최적화해 사용하는 방법을 직접 개발하는 등의 노력을 기울이며 3D 입체효과 면에서 진일보한 성과를 이루어 낸다. <미스터 고>에서 검증된 국내 3D 입체영상 기술의 신뢰도를 바탕으로 필자가 기획한 <터널 3D>(2014)에서는 Z축으로의 확장이라는 3D 영화의 속성을 최대한 고려한 깊이감 있는 공간과 특히 등장인물의 주관적인 시선에 해당되는 시점 쇼트를 적극적으로 도입해 관객들이 주인공이 느끼고 있는 공간에 대한 공포를 함께 ‘체험’할 수 있도록 노력했다. 3D 입체영상의 핵심은 축간격과 컨버전스에서 나오며 컨버전스를 연출자의 의도대로 조절함으로써 공간감을 다르게 표현할 수 있다. 본 연구에서는 3D 영화의 P.O.V에서 피사체가 돌출 또는 후퇴되는 입체감이 기술적으로 어떻게 표현되는지 살펴보고 그러한 효과들이 관객에게 어떻게 다가갈 수 있는지 고찰한다. 그리고 그러한 것들을 바탕으로 어떤 연출과 기술적인 접근이 P.O.V 콘텐츠 연구에 효과적인지 탐구해 보고자 한다. 기존 2D 영화와 다르게 관객에게 수용되는 3D 영화의 특성을 통해 P.O.V라는 영화 언어가 어떻게 변화해 가고 있는지 고찰하고자 한다
        6,300원
        387.
        2015.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to clarify the aesthetic values between emotion of human and expression of technology in contemporary fashion as it analyzes formative characteristics of related cases in fashion based on principles of 3D Printing technology and the viewpoint of mechanic aesthetics. The conclusions of this study are as follows. First, 3D Printing fashion is not only expressed diverse variations by its principles of formative methods, materials and properties, but also changes of silhouette by applying system of designers. Second, general characteristics of 3D Printing fashion is represented by various applications in SLS system, and it can be specifically explained application to a portion of clothing, decorative roles of clothing, complicated pattern making through crossing fabrics using 3D scanner and displaying a certain object changing fashion styles, and so forth. Third, the formative characteristics of 3D Printing fashion from the perspective of mechanic aesthetics is as follows. It can be analyzed as the integration of metaphysical values through compared symbolization of natural feature and technical evolution, partial dynamics and interactive velocity-based, formative combinations for abstract expression using architectural components, cosmos images and substantialized structures through images of organic space interacted human shapes. As the mention above, 3D Printing technology can creative a diverse area of fashion, and express images of new technological fashion through various works with continuous development of techniques.
        4,900원
        388.
        2015.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to use a 3D human body scanner to analyze the cross section of different body parts when a girdle is worn. Two types of girdles were selected as experimental garments: a standard type girdle (Garment A) and a high-waist type girdle (Garment B). Their sizes were 88 (S) and 94 (M). Ten female subjects in their twenties who wear girdles sizes 88 (S) and 94 (M) participated the experiment. Their bodies were scanned three times with the 3D human body scanner, before and after wearing experimental girdles. The data were collected by overlapping the cross sections of the 3D scanned body shape data. The space length was measured from the overlapped cross sections. The results show that human body silhouette are changed after wearing the compression type garments and the amount and place of the body change is different by style of garments. First, the waist girth shape became rounder. Second, there was a definite difference in space amount at abdomen girth between two types of girdle. The abdomen area was pushed toward the front after wearing the standard type girdle (A). The high-waist type girdle (B) pushed abdomen area toward the back. Third, there was clear difference at the hip area after wearing two types of girdle. The hip area pushed toward the front with the standard type girdle (A) and pushed toward the back with the high-waist type girdle (B).
        4,300원
        390.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 리뷰에서는 금속 3D프린팅 산업과 시장에 결정적인 역할을 하는 금속 분말소재와 관련기술의 R&D 전략 수 립을 위한 최근 우리 정부의 노력을 살펴보고 이를 토대 로 우리나라의 분말야금분야 R&D 및 새로운 PM 시장창 출에 관한 발전을 전망해보고자 한다. 따라서 본 리뷰의 내용은 2014년 12월에 미래창조과학부와 산업통상자원부 가 공동으로 수립하여 발간한 3D프린팅 전략기술 로드맵 을 기초하여 작성되었다.
        20,000원
        391.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is designed to analyze the similarity of fit and appearance between 3D virtual torso length sloper with real torso length sloper according to three 3D virtual clothing simulation programs (Optitex, CLO 3D, i-Designer), three body types (A, N, H) and fit status. We selected three representative body type models of females aged 20~30 and got their direct body measurements. Using these body measurements, we developed three 3D avatar body models and made three torso length fitted sloper with long sleeves. Thirty expert fit judges consisting of technical designers and graduate students assessed the similarity of fit and appearance between 3D virtual clothing and real clothing by observing images classified into front, back and side scene. We conducted ANOVA and post-hoc analyses to compare fit and appearance between real clothing and virtual clothing depending on three program. The results showed that CLO 3D represented fit and silhouette most similarly among the programs, especially girths, width and length. i-Designer tended to be relatively good to represent stress fold amount and silhouette. Optitex was assessed relatively better in expressing ease amounts in torso girths and armscye girths, but relatively worse for width, length, stress fold amount and silhouette.
        5,400원
        392.
        2014.12 KCI 등재 구독 인증기관·개인회원 무료
        목 적 : 생체부분간이식(Living Doners Liver Transplantation. 이하 LDLT)에서 간 공여자가 수술 전에 검사하는 자기공명췌담관조영술(Magnetic Resonance Cholangio Pancreatograpy, MRCP)은 T2효과를 높여 간 담도내의 해부학적 구조물을 잘 관찰하기 위한 검사이다. 이에 본 논문에서는 간 좌우엽으로 연결되는 hepatic ducts의 구조를 3D-MRCP post-processing함으로 그 유용성을 알아 보고자 한다. 대상 및 방법 : 2013년 12월부터 2014년 2월까지 본원에 간 공여자로 내원한 환자 총50명(남자:29명 여자:21명, 평균나이:29.6세)을 대상으로 하였다. 영상은 2D-MRCP 4 cm 두께의 radial (oblique coronal) & oblique axial projection image 얻고, 3D-MRCP는 respiration-triggering sequence로 source images 1㎜를, GE Workstation (AW volumeshare 4.6)에서 3D기법 중 MIP(Maximum Intensity Projection)와 VR(Volume-rendered)으로 간담관에 평행하게 Slabs와 angle 주어 oblique coronal로 재구성한 후, oblique coronal image plane에서 double angle을 주어 hepatic ducts 잘 보이도록 방사선사 1명이 영상처리했다. 평가방법은 정성적 분석으로 biliary track와 hepatic ducts의 해부학적 구조와 명확도를 2D-MRCP와 3D-MRCP 영상처리 image를 비교하여 방사선과 전문의 2명이 판독했다. 결 과 : 3D-MRCP는 영상처리 시 다양한 slabs 두께로 coronal oblique MIP image에서 double angle 주면 좌우 간담관분지를 찾을 수 있었다. 3D-MRCP와 2D-MRCP의 영상처리 데이터를 비교했을 때, 2건(4%) 간담관의 해부학적 구조가 다르게 나타났고, 15건(30%) 명확한 해부학적 구조를 확정하는데 도움이 되었다. 결 론 : 간 공여자의 간담관 Type은 다양하고 복잡하기 때문에 영상처리 시 주의가 필요하다. 각 공여자마다 간담관의 구조, 길이, 굵기 및 간실질의 대조도 분해능이 다르기 때문에 적당한 slabs angle를 적용해야 한다. 3D MRCP post-processing은 LDLT 수술을 계획하는 외과의에게 정확한 정보를 제공하므로 간 공여자의 안전과 수술시간 단축에 기여할 수 있으리라 사료된다.
        393.
        2014.12 KCI 등재 구독 인증기관·개인회원 무료
        목 적 : 삼차신경통은 심한 전기적 통증, 전 격통이 삼차신경 분지 중 하나 혹은 그 이상의 영역에 걸쳐 나타나는 안면통증 증후군이다. 삼차신경통의 발생기전은 정확히 알려져 있지 않으나 대부분의 경우 특별한 원인을 찾을 수 없는 특발형이다. 이에 본 연구에서는 삼차신경통 환자의 진단에 있어 중요한 Protocol인 3D VISTA와 3D SPACE를 비교하여 진단적 가치에 도움이 되는 Sequence를 알아보고자 하였다. 대상 및 방법 : 2013년10월 1일부터 12월 30일까지 본원에서 검사한 환자 20명을 대상으로 조사하였다. 남성9명, 여성 11명 이었으며 평균 연령은 52세였다. 검사에 사용된 장비는 3.0T 자기공명 영상 장비(Siemens skyra, Phillips Ingenia)를 이용하여 cranial nerve를 검사하였다. 사용된 Siemens skyra 3D SPACE 매개변수로는 TR/TE:1190/203ms, matrix: 320×320, Slice thickness: 0.5mm, Flip angle: 135, slice/slab: 112, voxel size: 0.28×0.28×0.5를 이용하였다. Phillips Ingenia 3D VISTA 매개변수로는 TR/TE: 2000/200ms, matrix: 320×320, Slice thickness: 0.6mm, Flip angle:90°, slice/slab: 100, voxel size:0.6×0.6×0.6 를 이용하여 영상을 획득하였다. 평가방법은 정량적 분석과 정성적 분석을 통해 영상을 분석하였으며, 정량적 분석은 trigeminal nerve와 Cerebellum에 ROI를 신호 대 잡음비(SNR)와 대조도 대 잡음비(CNR)를 측정하였다, 정성적 분석은 3D VISTA와 3D SPACE의 영상으로 해부학적 구조의 명확도와 전반적인 영상의 평가를 방사선사 3명 전문의2명에게 의뢰하여 정성적 분석을 하였다. 결 과 : 정략적 분석한 결과 3D VISTA 와 3D SPACE 평균 신호대 잡음비는 trigeminal nerve right/left 173.01/213.47평균 신호대 잡음비는193.24로 측정되었고, 3D SPACE의 trigeminal nerve right/left 99.61/130.83 평균 신호대 잡음비는115.22로 측정되었고, Cerebellum 137.32/58.06으로 측정되었다. 3D VISTA 와 3D SPACE sequence의 trigeminal nerve와 Cerebellum의 평균 대조도 대 잡음비는 114.74/120.18로 측정 되었다(p<0.05). 정성적 분석으로는 trigeminal nerve와 Cerebellum의 영상을 영상의학과 판독의 1명, 신경과 전문의 1명 방사선사 3명에게 의뢰하여 인공물 발생 정도, 해부학적 구조의 명확도, 영상선명도 및 전체적인 영상의 질을 평가한 결과 3D VISTA와 3D SPACE 영상이 4.3/4.1로 측정되었다(p<0.05). 결 론 : 고자장의 MRI 장비의 개발과 보급, 새로운 검사기법의 개발로 인해 현재 측두골과 같은 미세한 구조물이 주를 이루는 부위의 검사에서 MRI검사의 진단적 가치와 효용성은 다른 검사에 비해 탁월하여 질병의 확진과 치료 과정에서의 예후 등을 평가할 수 있기에 임상적 가치가 매우 높다고 평가받고 있다. 3TMR 장비에서 사용하는 sequence 중 T2 강조영상을 대표하는 3D VISTA와 3D SPACE를 비교해본 결과 3D VISTA sequence가 SNR이 높게 측정이 되었으나 CNR을 비교해 보면 SPACE sequence가 높게 측정 되었다. 두 가지 매개변수에서 정량, 정성 평가는 큰 차이를 보이지는 않고 있다. 따라서 정확한 판독을 위하여 DWI, Post 3D FLAIR 을 추가하여 사용한다면 진단에 유용하리라 사료된다.
        394.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 족관절 염좌 환자의 자기공명영상 검사 시 전하경비인대(AITFL)와 전거비인대(ATFL)를 관찰하기 위한 사방향 관상면(oblique coronal plane) 2D FSE 영상과 Isotropic 3D FSE Cube 영상의 비교를 통하여 그 유용성에 대하여 알아보고자 하였다. 대상 및 방법 : 2013년 10월부터 2013년 12월까지 족관절 염좌를 주 호소로 본 기관을 내원한 환자 15명(남자: 6명, 여자: 9명)을 대상으로, 사방향 관상면 2D FSE 기법과 시상면 3D FSE Cube 영상기법을 이용하여 AITFL과 ATFL의 영상을 획득하였다. 획득한 영상에서 AITFL과 ATFL, 골조직, 배경신호의 SI 및 CNR을 측정하고, Mann-Whitney U-검정으로 두 기법간의 통계적 유의성을 검증하여 정량적 평가를 하였다. 또한 영상의학의 2명이 각각의 영상에서 보여지는 AITFL과 ATFL의 형태 및 연속성, 부분용적에 의한 인공음영, 병변의 묘사정도의 3가지 항목을 4점 척도(0: 진단불가-Non diagnostic, 1: 부족함-Poor, 2: 적합함-Adequate, 3: 좋음-Good)로 평가하고, 평가결과 간의 일치도 검증을 위하여 Kappa-value(SPSS 19) 검정을 통해 통계적 유의성( p<0.05)을 검증하여 정성적 평가를 하였다. 영상획득에 사용된 장비는 3.0T MR 장비와 Extremity RF Coil을 사용하였다. 결 과 : 정량적 평가에서 CNR의 평균값은 AITFL의 경우 사방향 관상면 2D FSE영상에서는 10.72±0.01, 3D FSE Cube 영상에서는 18.66±0.52이었다. ATFL의 경우에는 사방향 관상면 2D FSE 영상에서는 5.62±0.98, 3D FSE Cube 영상에서는 8.15±0.65이었다. AITFL과 ATFL 모두 3D FSE Cube 영상에서 CNR 값이 높았으며, 두 영상기법 간의 CNR 값의 비교는 통계적으로 유의하였다( p<0.05). 정성적 평가에서 관찰자 1에 의한 AITFL의 형태 및 연속성, 부분용적에 의한 인공음영, 병변의 묘사정도의 평가결과는 사방향 관상면 2D FSE 영상의 경우 2.4±0.5, 2.5±0.5, 2.6±0.5의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.8±0.3, 2.9±0.2, 2.9±0.2의 순으로 값을 나타냈다. ATFL의 경우는 사방향 관상면 2D FSE 영상에서 2.5±0.5, 2.3±0.4, 2.5±0.5의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.8±0.4, 2.9±0.2, 2.9±0.2의 값을 나타냈다. 관찰자 2에 의한 AITFL의 형태 및 연속성, 부분용적에 의한 인공음영, 병변의 묘사정도의 평가결과는 사방향 관상면 2D FSE 영상의 경우 2.4±0.5, 2.3±0.8, 2.6±0.4의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.8±0.3, 2.8±0.3, 2.8±0.3의 값을 나타냈다. ATFL의 경우는 사방향 관상면 2D FSE 영상에서 2.8±0.4, 2.4±0.5, 2.8±0.5의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.9±0.2, 2.9±0.2, 2.9±0.2의 순으로 값을 나타냈다. AITFL과 ATFL 모두 3D FSE Cube 영상에서 평가 결과가 높게 나타났으며, 두 관찰자 간 평가결과의 일치도 검정은 통계적으로 유의하였다( p<0.05). 결 론 : 족관절 염좌 환자에서 3D FSE Cube 영상이 사방향 관상면 2D FSE 영상에 비해 AITFL과 ATFL의 손상 감별 및 기타 인대손상의 평가에 매우 유용하다는 것을 알 수 있었다
        4,800원
        395.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 환자의 피폭을 줄이기 위하여 발작성 심방세동(Paroxysmal Atrial fibrillation) 환자의 경우 전극도자절제술(RFCA) 시술 전 치료 계획을 세우기 위하여 시행되는 영상의학 검사로써 Pulmonary-Vein MRI를 선호하는 추세이다. 왼 심방의 용적을 측정하거나 섬유화 된 조직과 같은 부정맥을 유발할 수 있는 원발 부위를 찾는데 용이한 3D Inversion Recovery Turbo Filed Echo Late Gadolinium Enhancemnt 영상에서 왼 방실판막(Mitral valve)과 정상적인 혈류(Blood pool) 간에 신호대조도를 높이기 위한 적정 지연시간을 설정하는 것이 중요하다. 이에 본 논문은 발작성 심방세동 환자들에 대해 시술 전 치료계획을 세우기 위한 3D IR TFE영상에서 지연시간에 따른 신호대 잡음비(SNR)와 대조도 대 잡음비(CNR)의 측정을 통하여 적정 지연 시간의 임상적 유용성에 대해 알아보고자 한다. 대상 및 방법 : 2013년 12월 1일부터 2월 5일까지 발작성 심방세동으로 내원한 환자 중 체중이 60~70kg 사이의 환자 10명(남자 7, 여자 3, 평균연령 55세)을 대상으로 하였다. 장비는 3.0T 초전도자기공명영상장치 Achieva TX(Philips medical system, Netherlands)를 사용하였고, Coil은 32-channel SENSE cardiac coil을 사용하였다. 영상변수는 TR: 4.9ms, TE: 1.48ms, Matrix: 200×200, Slice thickness: 1.5mm, NEX: 1로 하였으며, 조영제 주입 후 5분, 10분, 15분, 20분, 25분마다 3D IR TFE영상을 얻었으며, 왼 방실판막과 정상혈류 간에 신호강도, 신호대 잡음비 그리고 대조도 대 잡음비를 측정하여 정량적 분석을 하였으며, 정성적 평가로는 10년 이상 경력의 4명의 방사선사가 4점을 기준으로 하여 점수화 하였다. 결 과 : 정량분석 결과 5분의 지연시간을 가질 때 왼 방실판막에서의 평균 SNR과 정상적인 혈류와의 평균 CNR은 각각 88.48과 12.35, 10분에서는 119.92과 22.34, 15분에서는 124.39와 32.86, 20분에서는 106.82과 29.59, 25분에서는 74.96과 29.97으로 조영제 주입 후 15분이 지난 후의 영상에서 가장 높은 대조도의 차이가 생겼으며, 시간이 지남에 따라 전체적인 신호강도가 줄어든다는 것을 알 수 있었다. 각각의 시간에 따른 SNR과 CNR에서의 차이는 p값 0.05이하로써 통계적으로도 유의함을 증명하였다. 정성적 분석에서도 조영 후 15분이 지난 모든 영상에서 높은 점수를 받았다. 결 론 : 3D IR TFE LGE기법은 발작성 심방세동 환자들에게 시술을 위한 원발 부위 치료계획을 설정함에 있어 매우 유용하다. 그 중에서도 조영 후 15분이 지난 후 얻게 되는 영상에서의 진단학적 가치가 제일 높은 것으로 나타났으며, 추후 환자에 따른 체적을 고려하여 적절한 조영제 양과 체적에 비례한 지연시간을 설정하여 검사를 진행한다면 양질의 진단적 가치가 우수한 영상을 얻을 수 있으리라 사료된다.
        4,000원
        396.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 지금까지 생체 부분 간 이식을 위한 공여자의 간 용적 측정에서 방사선을 이용한 CT 3D 용적측정 검사가 매우 우수한 측정방법으로써 시행되고 있으며, 추가적으로 수술 시 공여자의 안정성 판단을 위해 MR 검사가 함께 시행되고 있다. 이에 본 연구에서는 MR 검사와 CT 검사를 함께 시행한 공여자를 대상으로 각각 3D 용적측정 후 그 우수성을 비교 분석해보고자 하였다. 대상 및 방법 : 대상은 간 이식 수술 전 MR 검사와 CT 검사를 함께 시행한 공여자로 남자 23명, 여자 7명이었고, 평균나이 29.1세였다. 검사장비로는 MR Systems Achieva Release 3.2.2.0와 CT Brilliance 64CH를 사용하였으며, 분석장비로는 MR Adw 4.2와 CT Mx View 3.5를 사용하였다. 검사방법은 Primovist 조영제를 사용한 MR 검사 eTHRIVE Portal Phase(Fov 340×340, Thickness 5.0mm) 영상을 MR Adw 4.2 Workstation에서 용적을 측정하였으며, Ultravist 조영제를 사용한 CT 검사는 CT Hepatobiliary Portal Phase(FOV 350×350, Thickness 3.0mm) 영상을 Thickness 5.0mm로 Reconstruction 후 Mx View Workstation에서 용적측정 하였다. 분석방법은 MR 3D 검사와 CT 3D 검사에서 측정된 전체 용적 측정값과 좌엽 용적 측정값이 일치하는지 분석하였다. 공여자의 안정성 판단에서 중요한 사항으로 나타내는 우엽 용적 측정값 비교에서는 실제 수술실에서 적출한 우엽 간 용적값을 MR 3D와 CT 3D의 우엽 용적 측정값과 각 각 비교 분석하였다. 통계방법은 SPSS version 18.0를 사용하여 대응표본 t-test(p < 0.05)와 Pearson 상관계수로 검증하였다(r > 0.001). 결 과 : MR 3D 검사의 전체 용적 측정값은 1238cm³이며, CT 3D 검사는 1402cm³로 전체 평균 용적 측정값이 차이를 보였다(p < 0.05). 좌엽 간의 MR 3D 검사에서 용적 측정값은 450cm³이며, CT 3D 검사에서 용적 측정값은 554cm³으로 좌엽 용적 측정값의 차이를 보였다(p < 0.05). 우엽 간 측정값은 수술 후 적출한 우엽 간 평균 용적 측정값이 678g이었으며, CT 3D 검사의 우엽 용적 측정값은 847cm³(r=0.852)였고, MR 3D 용적 측정값은 787cm³ (r=0.871)로 측정되었다. 결 론 : 지금까지 간 이식 공여자는 이식 될 우엽 간을 미리 예측하기 위하여 주로 CT 3D 용적 측정검사를 하였다. 그러나 MR 3D 용적 측정검사 역시 CT 3D 용적 측정검사와 함께 매우 정확하고 우수한 측정방법으로써 증명되었으며, MR 3D 용적 측정검사가 간 이식 전 공여자의 안정성 판단에 중요한 검사가 될 것으로 사료된다.
        4,000원
        397.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to analyze the breast growth variation trends and characteristics of Korean adolescent girls based on 3D body measurements. Subjects were 174 girls aged between 13 and 18. 3D body scanning data were collected and the data were measured by Geomagic Design X program. The total of 18 anthropometric measurements and 4 index items were analyzed. The main results of this study are as follows: 1) Overall, the breast growth of adolescent girls got out of children's body shapes at the age of 14 and the adult's body shapes appeared remarkably at the age of 18. Before the age of 15, the adolescent girls' breast enlarged. 2) The surface lengths of upper body, which means the breast volume, showed significant growth above B cup groups rather than under A cup groups. The demand of B cup size (32.2%) was higher than A cup size (25.9%). And 35.6% of subjects' brassiere band size was 70. 3) The thorax grew evenly in the circumference, depth and breadth. The thoracic development related to the breast volume as well as the whole upper body's development. These results reveal that it is necessary to develop adolescent girls' brassiere reflecting on adolescent girls' breast growth variation trends and characteristics by age, breast size and thoracic development.
        4,300원
        398.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 3차원 직선교 모델의 객체인식을 통해 각 객체별 고유 명칭을 부여하는 알고리즘을 제시한다. 3차원 객체의 수치적 인식을 위해 국부 좌표계 상의 솔리드 객체 도심 좌표를 활용하였으며, 객체의 분류, 부재의 구분, 교량 방향 인식 등을 수행하여 객체특성집합을 정의하였다. 이를 통해 경간정보, 부재정보, 객체의 순서정보를 포함한 객체별 고유 명칭을 부여하였고, 트러스 교량 모델 및 서로 다른 좌표계를 갖는 교량모델에 적용하여 각 부재별 객체특성집합을 이용한 명칭의 부여의 적합성을 검토하였다. 또한 실제 교량의 3차원 모델을 대상으로 제안된 방법론을 통해 객체특성집합 정의 및 객체별 명칭을 부여하였고, 이를 매개로 모바일 장치용 모듈과 로컬 서버용 모듈에 적용하였다. 객체인식을 통한 명칭부여 알고리즘을 활용한 방법과 기존 현장점검 방식의 비교를 통해 기존 유지관리 현장점검 업무를 효과적으로 개선할 수 있음을 확인하였다.
        4,000원
        399.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The necessity of large-area and high-precision measurements has increased in industry area. The high-speed/high-precision multi probe measurement system has been developed to measure the 3D shape. The three different multi probes are combined in measurement system. This system is synchronized between the probes to measure the same position in the sample. Also this paper shows the measurement results with multi probe measurement system.
        4,000원
        400.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 2D 화면과 3D화면으로 각각 제시된 운전 시뮬레이션 환경에서 운전자의 종적 차량통제, 주관 적 피로감 및 지각된 현실감에서의 차이를 비교하였다. 본 연구의 결과들을 요약하면 다음과 같다. 첫째, 실험참 가자들은 미리 정해진 네 가지 수준의 목표속도(60, 80, 100 및 120km/h)를 유지할 때 3D 조건보다는 2D 조건에 서, 그리고 목표속도가 낮을수록 목표속도에 비해 더 빠르게 운전하였고, 이러한 경향은 목표속도 조건과 상관없 이 일정하였다. 둘째, 선행차량과의 차간거리 유지수행에 대한 분석 결과, 2D 조건에 비해 3D 조건에서 실험참가 자들은 선행차량과 더 근접한 차간거리를 유지하며 주행하였는데, 특히 선행차량의 주행속도가 비교적 느렸던 조건(즉, 60km/h)에 비해 비교적 빨랐던 조건(즉, 80 및 100km/h)에서 이러한 경향이 두드러졌다. 셋째, 속도 유지 과제와 선행차량과의 차간거리 유지수행 모두에서 2D 조건에 비해 3D 조건에서 실험참가자들이 경험하는 피로 감의 수준이 더 높았으나 주관적 현실감에 대한 평가에서는 두 가지 과제 모두에서 2D와 3D 조건에 따라 유의 한 차이가 관찰되지 않았다.
        4,900원