검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 84

        23.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we utilize a Gaussian process to predict the power consumption in the air-conditioning system. As the power consumption in the air-conditioning system takes a form of a time-series and the prediction of the power consumption becomes very important from the perspective of the efficient energy management, it is worth to investigate the time-series model for the prediction of the power consumption. To this end, we apply the Gaussian process to predict the power consumption, in which the Gaussian process provides a prior probability to every possible function and higher probabilities are given to functions that are more likely consistent with the empirical data. We also discuss how to estimate the hyper-parameters, which are parameters in the covariance function of the Gaussian process model. We estimated the hyper-parameters with two different methods (marginal likelihood and leave-one-out cross validation) and obtained a model that pertinently describes the data and the results are more or less independent of the estimation method of hyper-parameters. We validated the prediction results by the error analysis of the mean relative error and the mean absolute error. The mean relative error analysis showed that about 3.4% of the predicted value came from the error, and the mean absolute error analysis confirmed that the error in within the standard deviation of the predicted value. We also adopt the non-parametric Wilcoxon’s sign-rank test to assess the fitness of the proposed model and found that the null hypothesis of uniformity was accepted under the significance level of 5%. These results can be applied to a more elaborate control of the power consumption in the air-conditioning system.
        4,000원
        24.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to advancements in technology and manufacturing capability, it is not uncommon that life tests yield no or few failures at low stress levels. In these situations it is difficult to analyse lifetime data and make meaningful inferences about product or system reliability. For some products or systems whose performance characteristics degrade over time, a failure is said to have occurred when a performance characteristic crosses a critical threshold. The measurements of the degradation characteristic contain much useful and credible information about product or system reliability. Degradation measurements of the performance characteristics of an unfailed unit at different times can directly relate reliability measures to physical characteristics. Reliability prediction based on physical performance measures can be an efficient and alternative method to estimate for some highly reliable parts or systems. If the degradation process and the distance between the last measurement and a specified threshold can be established, the remaining useful life is predicted in advance. In turn, this prediction leads to just in time maintenance decision to protect systems. In this paper, we describe techniques for mapping product or system which has degrading performance parameter to the associated classical reliability measures in the performance domain. This paper described a general modeling and analysis procedure for reliability prediction based on one dominant degradation performance characteristic considering pseudo degradation performance life trend model. This pseudo degradation trend model is based on probability modeling of a failure mechanism degradation trend and comparison of a projected distribution to pre-defined critical soft failure point in time or cycle.
        4,000원
        25.
        2015.04 구독 인증기관·개인회원 무료
        국내 유입시 경제적 피해가 예상되는 주요 관심 침입우려 병해충에 대한 발생예찰모형을 개발하여 기후시나리오에 따른 국내 정착지역을 추정하고, 국내 기상환경에서 발생시기를 추정하여 기후변화에 대응한 검역해충 예찰 업무시 현장 활용이 가능한 예측시스템을 구축하였다. 대상 병해충으로는 감귤그린병매개충, 참나무역병, 과실파리류, 코드린나방, 자두애기잎말이나방, 유사코드린나방, 미국사과애기잎말이나방, 복숭아뿔나방이 구현되었다. 병해충의 생리적 기작에 기반한 발생예찰모형을 개발하고, 이 모형을 활용하여 국내 환경에서 병해충 발생 예측이 구현 가능하여 핵심 예찰시기를 결정할 수 있고, 정착 적합도를 이용하여 발견 가능성이 높은 지역을 선택할 수 있다. 미래 정착 가능성을 판단하기 위하여 기상청 RCP 8.5 기후변화 시나리오를 이용한 미래 병해충 정착 적합도를 계산하고 2010s~2090s까지의 년대별 국내 정착적합 분포지도를 제공한다. 정착시 국내 발생 예측은 기상청 자동기상관측자료를 이용한 국내 기상 환경에서의 일별 병해충 발생 예측 분포 지도를 조회하고 지도상의 임의 지점의 년간 병해충 발생 위험정도를 시계열 그래프로 조회할 수 있다. 예찰업무 지원을 위한 시스템으로 GIS 서비스 및 예찰지점의 병해충 발생 예측량 시계열 그래프를 통한 예찰 방제 모니터링 기능이 포함되었다. 또한 기후 예측인자·요소가 병해충 발생 위험수준에 도달하였을 경우 위험단계별 경보를 예찰요원의 휴대전화번호로 자동 발송하는 기능이 포함되었다.
        26.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        전지구 해양 해빙 예측시스템인 NEMO-CICE/NEMOVAR의 해빙 초기조건의 특성을 2013년 6월부터 2014년 5월까지 북극영역에 대하여 분석하였다. 이를 위하여 관측 자료와 재분석 자료를 모델의 초기조건과 비교하였다. 모델 초기조건은 관측에서 나타나는 해빙 면적과 해빙 두께의 월 변동을 잘 보이는 반면, 분석 기간 동안 관측과 재분석 자료보다 북극의 해빙 면적을 좁게, 해빙 두께를 얇게 나타내었다. 모델 초기조건의 북극 해빙 면적이 좁은 것은 해빙의 경계 지역에서 해빙 농도 초기조건이 약 20% 정도 재분석자료보다 낮기 때문이다. 또한 북극 평균 해빙 두께가 얇게 나타나는 이유는 연중 두꺼운 해빙이 유지되는 그린란드 및 북극 군도와 인접한 북극해 영역에서 모델의 초기조건이 약 60 cm 정도 얇기 때문이다.
        4,000원
        27.
        2014.05 구독 인증기관·개인회원 무료
        오늘날 물류 서비스 산업에서는 수요예측을 통해 불확실성을 줄여나가는 것이 경영상 매우 중요한 이슈로 제기되고 있다. 비교적 시장 점유율이 견고하게 유지되는 제조산업과는 달리 물류 서비스 산업은 매우 빠른 속도로 시장이 성장하고 변화하기 때문에, 시장 환경의 변화를 반영하여 정확한 수요 예측에 기반한 적절한 물류 서비스 공급을 위한 운송 및 인력 공급 계획을 수립하여 운용하여야 한다. 본 연구는 물류 서비스 업계를 위하여 추세 요소, 계절 요소 등 수요에 영향을 미치는 요소를 분석하고, 영향 효과를 산출하여 물류 서비스 산업을 위한 수요예측 시스템에 반영하는 방안을 연구하였다. 특히 지역 특산물, 기상효과, 음력으로 발생하는 명절 효과 등 수요를 크게 변화시키는 중요 영향 요소에 의한 수요 변동을 수요 예측에 활용하는 방안을 도출함으로써, 물류 서비스 산업계의 수요 예측을 위하여 분해법(Decomposition Method)을 제시하였다.
        28.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현재 최고 수준의 대순환 모형에서 북동아시아 여름몬순 강도의 계절예측 능력은 낮으나 북서태평양 아열대 고기압 강도의 예측률은 상대적으로 높다. 북서태평양 아열대 고기압은 북서태평양 지역 및 동아시아 지역에서 가장 주된 기후 변동성이다. 본 연구에서 NCEP 계절예측시스템에서 예측된 북서태평양 아열대 고기압의 예측성에 대해 논의될 것이다. 한편, 북동아시아 여름몬순의 경년변동성은 북서태평양 아열대 고기압과 높은 상관성을 가지고 있다. 본 연구에서는 이 관계에 근거하여, NCEP 계절예측시스템과 정준상관분석을 이용한 계절예측 모형을 제안하고 그 예측률을 평가하였다. 이 방법은 북동아시아 지역 여름철 강수량 편차에 대한 계절예측에 있어 통계적으로 유의한 예측성능을 제공한다.
        4,000원
        29.
        2013.10 구독 인증기관 무료, 개인회원 유료
        Virtual metrology(VM) is a promising technology which can convert off-line sampling inspection into on-line total inspection at the manufacturing process. This paper provides an economic evaluation model of VM system which predicts the defects of a target process with Bernoulli sampling inspection. For this purpose, we build M/G/1 queueing models of two systems. One is VM non-applied system and the other is VM applied one. We derive total costs per unit time of each system and conduct sensitivity analysis according to variations of input parameters such as defect rates, various process costs and VM prediction error rates. The proposed analysis model is expected to be used for evaluating economic values of VM system implementation projects.
        4,000원
        30.
        2013.10 구독 인증기관·개인회원 무료
        농촌진흥청에서는 농작물 병해충 발생에 신속하게 대응하여 농가피해를 최소 화할 목적으로 ‘10년도부터 웹GIS (Geographical Information System)를 기반으 로 한 국가농작물병해충 관리시스템(National Crop Pest Management System, NCPMS)을 구축하였다. 본 시스템(http://ncpms.rda.go.kr)은 크게 병해충 예찰, 예 측, 진단, 동아시아병해충네트워크로 구성되어 있다. ‘12∼‘13년도 시스템 고도화 사업을 통하여 예찰작목을 16개에서 24개 작목으로 확대하였고, 이동·돌발성 7종 해충 발생 시 인접 행정구역의 시군농업기술센터에 발생경보 발송 및 발생조사자 료 입력·관리가 가능한 해충조기경보시스템을 신규로 구축하였다. 그리고 주요 농 작물 해충의 천적 30종에 대한 생태, 이미지, 이용방법 등 시험연구사업의 결과물 을 도감으로 구축하여 종합적인 해충 방제법에 대한 이해를 증진시켰다. FTA대응 농축산물 경쟁력 제고를 위한 병해충 예측모형 개발연구사업에서 개발된 15개 병· 해충 예측모형을 추가로 시스템에 탑재하였고, 중국에서 비래하는 장거리 이동성 벼 해충의 국내 비래시기 및 이동경로를 예측하여 사전에 국내에서 대응책을 수립 할 수 있도록 해충이동경로 예측모델(Blayer 모델)을 구축하였다. 또한 중국, 일본, 베트남 등 13개국의 벼 해충 발생밀도를 집계하고 공유하는 동아시아병해충네트 워크의 회원국 관리 기능 등을 추가하여 사용자 편리성을 제고하였다. 이러한 NCPMS의 예찰, 예측, 진단정보를 병해충 방제의사결정에 활용함으로써 병해충 피해를 최소화하고 농가소득에 이바지할 것으로 사료된다.
        31.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, cycle performance analysis of two-stage compression and two-stage expansion refrigeration system using Natural refrigerants is presented to offer the basic design data for the operating parameters of the system. Alternative natural refrigerant R290(Propane), R600(Butane), R717(Ammonia), R1270(Propylene) for freon refrigerant R22 were used working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, and mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and two-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ration of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and two-stage expansion refrigeration system using alternative nreon refrigerants have an effect on COP of this system.
        4,000원
        33.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, cycle performance analysis of two-stage compression and one-stage expansion refrigeration system using alternative Freon refrigerants is presented to offer the basic design data for the operating parameters of the system. Pure alternative Freon refrigerant R32, R134a and near NARM(Non-Azeotropic Refrigerants Mixtures) R404A, R407C, R410A and ARM(Azeotropic Refrigerant Mixtures) R507A were used working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and one-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ration of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter- cooler of two-stage compression and one-stage expansion refrigeration system using alternative Freon refrigerants have an effect on COP of this system.
        4,000원
        34.
        2012.05 구독 인증기관·개인회원 무료
        농촌진흥청에서는 농작물 병해충 발생에 대하여 신속하게 대응하여 농가피해 를 최소화하기 위하여 2010년부터 2011년까지 웹GIS (Geographical Information System)를 기반으로 한 국가 병해충 관리시스템(National Pest Management System)을 구축하였다. 이 시스템(http://npms.rda.go.kr)은 크게 병해충 예찰, 예 측, 진단, 동아시아병해충네트워크로 구성되어 있으며 예찰자료 입력, 통계정보 조 회가 가능하고 웹지도상에서 발생분포를 확인할 수 있다. 병해충 예찰시스템에서 는 벼, 보리, 사과 등 11개 작물에 대해 지정된 해충과 병 발생 조사자료를 입력·관리 할 수 있다. 병해충 예측시스템에서는 국가농림기상센터의 기상자료를 이용한 격 자형 기상 추출값을 기반으로 벼, 사과, 배, 감귤, 고추의 주요 해충과 병에 대한 발 생예측결과를 웹지도상에서 예찰자료와 비교할 수 있다. 또한 해충·병·잡초 통합 DB를 병해충 진단시스템에 구축하여 해충·병·잡초 명칭 및 이미지 검색이 가능하 고 전문가에게 의뢰를 진단결과를 받아 볼 수 있다. 동아시아병해충네트워크에서 는 중국, 일본, 베트남 등 13개국의 벼에 발생하는 멸구류의 발생밀도를 집계하고 이를 통해 동아시아 국가 간 멸구류 이동 모니터링의 기반을 마련하였다. NPMS의 병해충 예찰, 예측정보는 병해충 방제의 기초자료로서 앞으로 이를 활용하여 병해 충 피해를 최소화하고 방제비용을 줄이는데 기여할 수 있을 것으로 사료된다.
        35.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        구조물 내 설치된 파이프시스템은 주로 내부구성원들의 인간생활에 근간이 되는 기반시설로서 현대 도시생활의 생명선과 같은 역할을 한다. 이들 구조물 내 파이프시스템이 만약 지진발생에 의하여 손상될 경우 1차적으로 구조물 내 기능성이 저하되고 구조물 내 많은 정신적, 물질적 피해가 발생할 수 있다. 실제 내진공학에서 지진발생에 따른 비구조재요소의 거동은 크게 중요하게 고려되지 않으나 인적 및 물적 피해와 매우 밀접하게 연관되는 가스 혹은 수계파이프시스템에 대한 비구조적 요소의 거동예측 및 성능평가 연구는 보다 효과적인 구조물 유지관리를 위하여 그 필요성이 크다고 판단된다. 본 연구는 현재 일반적으로 널리 시공되어져 있는 노후 철근콘크리트 빌딩구조물 내 설치된 가스 혹은 수계파이프시스템에 대하여 실제 지진발생이 예측되는 거동을 살펴보고 이들 거동에 따른 성능평가 및 현 설계기준에 대한 검토도 병행하여 수행하고자 한다. 이를 위하여 본 연구에서는 해석적으로 발생 가능한 총 10회의 지진파에 대하여 현재 실제 건물 내 기설치된 수계파이프시스템 모델링 및 해석을 통하여 그 결과를 검증, 평가하였으며 부가적으로 실제 발생 가능한 파괴유형 분석을 통하여 현 설치된 수계파이프시스템의 설계에 대한 적절한 내진보강방법에 대하여도 제안하고자 한다.
        4,000원
        36.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, cycle performance analysis of cascade refrigeration system using alternative FREON refrigerants are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and evaporating and condensing temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. Therefore, subcooled degree, evaporating and condensing temperature of cascade heat exchanger using alternative FREON refrigerants have an effect on the COP of this system. In this paper, COP of cascade refrigeration system using R23 for low temperature system and R507A for high temperature system is higher 8 ~ 29 % than using R13 for low temperature system and R22 for high temperature system.
        4,000원
        37.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        인간의 걸음걸이를 보고 느끼는 감성적 반응에는 모든 사람들이 공감할 수 있는 '규칙성'이 있다. 본 논문은 이러한 규칙성을 수량적으로 추출하고 재구성하여 3D 캐릭터 행동제어에 적용하고자 하는 연구과정의 일부분이다. <"가"라는 감성반응을 가지고 있는 걸음걸이 "A"와 "나" 라는 감성반응을 가진 걸음걸이 "B" 의 신체적 수치 데이터를 임의의 비율로 섞었을 때, 그에 대한 감성반응 역시 "가"와 "나" 가 섞인 "가/나"가 된다.>란 가설을 증명해서 향후 연구의 타당성을 확보하는 것이 이번 논문의 목적이다. 3D Studio Max의 스크립트로 만든 EAM을 이용하여, 바이페드 형식의 2개의 걸음걸이 샘플을 브랜딩 하였다. 6번 중 4번의 실험에서 성공적인 브랜딩 결과물을 추출할 수 있었다. 이것은 모션캡처 등을 이용하지 않더라도 기본적인 바이페드 데이터만 있다면 다양한 걸음걸이의 바이페드를 생산할 수 있다는 것을 의미한다. 현재 팔, 다리의 1Cycle 운동조건이 갖추어진 바이페드 샘플을 대상으로 하고 있지만, 완성된 시스템을 위해서는 다양한 운동조건에서도 브랜딩이 가능한 툴이 필요하다.
        4,000원
        38.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 유고로 인한 대기행렬, 통행시간과 같은 혼잡정보를 예측하여 제공하는 것을 목표로 하며, 이것은 교통시설 이용자와 운영자 모두에게 효율적인 대안선택 및 운영을 위한 중요한 요소로 활용된다. 이러한 예측된 사고영향 정보의 제공으로 인하여, 이용자는 유고 구간에 대한 정보를 사전에 인지하여 지체를 최소화 할 수 있고, 운영자는 현재 유고영향을 받을 것으로 예상되는 구간을 효율적으로 관리할 수 있을 것이다. 본 연구에서는 연속류 본선구간에서 단기예측기법을 적용한 유고영향 예측모형을 제안하였다. 본 연구에서 제안한 모형은 MARE를 통하여 상대적인 오차를 비교분석하여, 예측력이 뛰어난 모형을 정립하였다. 본 연구를 시작으로 미시적인 사고영향 예측 모형이 개발된다면 사고발생 시 지체를 최소화하고 사회적인 비용을 줄일 수 있을 것이다.
        4,000원
        39.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, cycle performance analysis of cascade refrigeration system using natural refrigerants R744 for low temperature cycle, and R290, R600, R600a, R717 for high temperature cycle are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and condensing and evaporating temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. The COP of cascade refrigeration system using natural refrigerants is similar to the COP using freon refrigerant (R23 / R22). Points to be considered are th security, the attached facilities for natural refrigerants than COP.
        4,000원
        40.
        2010.05 구독 인증기관 무료, 개인회원 유료
        본 논문은 국내외의 환경 변화와 기술 발전으로 우편 물류의 업무 방식이 바뀌어가고 또 소비자들의 우편 물류 사용에 대한 인식과 사용 방식이 변화하는 상황 속에서, 국내 우편 물류를 위한 수요를 예측하는 시스템 개발하여 그 결과에 의하여 시뮬레이션을 진행하거나 우편 물류 설비나 기지에 대한 의사결정에 활용하도록 하는 사례를 연구하였다. 특히 본 연구에서 개발한 수요예측 시스템은 한국의 사회 변화와 경기 변동을 보여주는 기술적인 통계치가 우편 물류에 미치는 영향을 분석하고, 한국의 우편 물류 사용자들의 패턴 변화를 중장기적인 시간의 흐름에 따라 분석하였으며, 이에 따라 시계열 예측과 인과형 예측을 진행하고 의사결정에 반영할 수 있도록 하였다.
        4,000원
        1 2 3 4 5