검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1,072

        81.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The new & renewable energy including solar heat has been widely used to reduce the fossil fuel. Air-heating collector of solar heat is usually known as technology that supplies the hot air to indoor room. However, this study aims to investigate the possibility of cold room by air-heating collector of solar heat. The thermal flow in cold room was simulated using ANSYS-CFX program and thus the behaviors of cold air were evaluated with standard k-ε turbulence model. As the results, there was space in indoor room not showing cooling effect in case that both inlet and outlet were installing at bottom. Inlet temperature showed greater cooling effect than inlet velocity. Furthermore it was confirmed that the location and the temperature, respectively, capable of cooling indoor room could be predicted by changing the attached position of inlet and outlet.
        4,000원
        82.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Although airborne wear particles (AWPs) generated from wheel-rail contacts are the major source of particulate matter (PM) in subway systems, studies on reducing the generation of such particles in order to enhance air quality are extremely rare. Therefore, this study investigated the effect of applying water-lubricant (applying tap water) on improving air quality by reducing the mass concentration (MC) of AWPs from wheel-rail contacts at a train velocity of 73 km/h using a twin-disk rig. An optical particle sizer was used to measure the MC of particles with the diameter range of 0.3 μm~10 μm. The results showed that the generation trends regarding PM1, PM2.5, and PM10 were different for dry and water-lubricated conditions: all three PMs showed an increasing-decreasing trend with slip rate under dry conditions; however, they were almost constant with slip rate under water-lubricated conditions. The particle size distributions were also different for dry and water-lubricated conditions: the peak occurred in multi-modal with the largest peak at approximately 6 μm in diameter under dry conditions; whereas, the peak occurred in bi-modal with the largest peak at approximately 0.9 μm in diameter under water-lubricated conditions. In addition, MCs were mostly smaller under water-lubricated conditions than dry conditions except at approximately 0.9 μm in diameter. Applying water significantly decreased PM1~2.5 and PM2.5~10 by more than 95%. This caused a decrease in PM2.5 and PM10 by 48.1% and 78.5%, respectively. On the other hand, applying water increased PM0.3~1 (i.e., PM1) by 52.8%, possibly owing to the effect of water vapor and mineral crystals from tap water. Overall, these findings indicate that water-lubrication can improve air quality in subway systems by reducing the MC of APWs generated from wheel-rail contacts. This study may provide a reference for future studies seeking to improve air quality in subway systems by reducing AWPs generated from wheel-rail contacts by applying lubricants.
        4,000원
        83.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seoul has installed mechanical air filters in the heating, ventilation, and air conditioning (HVAC) systems of city buses to improve their indoor air quality since late 2019. We evaluated particle removal efficiencies of the filter in a wind tunnel, and clean air delivery rates (CADRs) of the systems and a household air purifier in the buses, following the test standards. The filter showed the efficiencies of 91% and 97.6%, 88% and 97.9%, and 78% and 95.2% for 0.35 μm particles and PM2.5 at 1.0m/s, 1.5m/s, and 2.0m/s, respectively. The efficiencies rose with an increase in the particle size and the filters had a minimum efficiency reporting value (MERV) rating of 15. The CADRs for PM2.5 and flow rate of the systems were 12.7m3/min and 17.9m3/min, 16.6m3/min and 25.4m3/min, 18.7m3/min and 33.6m3/min, and 23.3m3/min and 47.1m3/min on the operation mode of 1, 2, 3, and 4, respectively. The CADRs of the systems were 3.8-7.1 times higher than those of the air purifier, but single-pass removal efficiencies of the former were 0.56-0.81 lower than those of the latter.
        4,000원
        85.
        2022.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study evaluated the Protaetia brevitarsis larvae powder’s characteristic changes using hot air drying (60±2.5oC, 12 h) with different pre-treatment methods, including two sacrifice methods, two storage temperatures, and two defatting processes. Appearance, yield, moisture contents, pH, color, proximate analysis, volatile basic nitrogen level, DPPH radical scavenging activity, and total phenol content were assessed. Results revealed that a combination of blanching, defatting, and -20oC storage temperature resulted in higher total phenol contents, lower water contents, and lower volatile basic nitrogen levels than other methods. Defatted treatment resulted in a higher L-value than the non-defatted treatment. Taken together, these results indicate that a combination of -20oC storage, blanching, and defatting is the optimal pre-treatment method for obtaining P. brevitarsis larvae powder with high total phenol content, low water content, and low volatile basic nitrogen, taking into account cost efficiency considerations.
        4,000원
        86.
        2022.05 구독 인증기관·개인회원 무료
        The background of the development is to contribute to the reduction of radioactive waste, recycling of resources and effectively purifying the air in the workplace. Ultimately, it affects the reduction of internal exposure of workers. According to the standard procedure of KHNP,「Use and Management of Respiratory Protection Equipment」, the expiration date of mask filter is indicated by the manufacturer before opening. It is 1 year from the date of first combination after opening. We have developed an air purifying equipment that can recycle and reuse expired mask filter waste in nuclear power plant. In order to confirm the performance, we observed air pollution level by operation time. The location was measured at 3 locations including the decontamination product warehouse in NPP, and the size of the measurement locations were 53 m3, 150 m3, 180 m3, and 900 m3. As a result of measurement, significant air purification effect was found in 53 m3 and 150 m3. Decontamination effect of 80% was shown after 1 hour of operation, and 20% of decontamination effect was shown gently for 3 hours thereafter. On the other hand, there was no significant decontamination effect in the 180 m3 and 900 m3 spaces. Significant results were derived by statistical methods. Statistical procedure involves the collection of data leading to test of the relationship between two statistical data sets, or a data set and synthetic data drawn from an idealized model. The basic composition and product characteristics was as follows: Blower, filter fixing unit, Air purifier outlet round shape, Differential pressure gauge, inverter (200 V, 3π, 200 W). The developed product weigh is 25 kg. This is lighter than the existing product weighing 100 kg. It is judged that it is suitable for convenient use. Because the area where the major air pollution level occurs is isolated by a room in NPP. This developed product has a greater significance in that it recycles radioactive waste within the radiation management area rather than air purification efficiency.
        87.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        수소는 지구 온난화의 주범인 온실가스(GHG) 배출을 감소시키고 선박용 친환경 연료로서 대두되고 있다. 수소는 가연 하한계 (Lower Flammability Limit, LFL)가 4 ~ 75 %이고 폭발 위험성이 큰 물질이다. 그래서 선박용으로 사용되려면 누출에 대비한 안전성이 충분히 확보되어야 한다. 본 연구에서는 수소탱크 저장실에서 수소 누출이 발생한 경우, 급․배기구의 면적 변화가 환기 성능에 미치는 영향을 분석하였다. 급․배기구의 면적은 1A = 740 mm × 740 mm이며 저장실 표면에 크기 및 위치 변경이 쉽도록 설정하였다. CFD 상용 소프트웨 어인 ANSYS CFX ver 18.1을 이용하여 급․배기구의 면적을 1A, 2A, 3A, 5A로 변경하였고, 면적 변화에 따른 저장실 내의 수소 몰분율을 분석하였다. 그 결과 급기구 면적이 배기구 면적 증가에 비해 누출 수소의 농도를 더 감소시켰으며 단일 급기구보다 최소 2A 이상에서 환기 성능이 향상되었다. 급기구의 면적이 증가할수록 수소 층화가 저장실 상부부터 균일하게 형성되었지만 LFL 범위는 벗어나 있었다. 그러나 배기구는 면적을 단순히 증가하는 것만으로는 환기 성능에 미치는 영향은 미비하였다.
        4,000원
        88.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this paper is to propose part management and standardization to reduce cost and increase compatibility of parts through standardization and standardization of parts to be applied to urban air mobility(UAM) systems, Personnel Air Vehicle(PAV), Vertical Take-Off and Landing (VTOL), and so on. In other words, parts used in the urban air transportation system must be verified from the initial design stage in accordance with the aviation standard, and a systematic management system for various parts must be established to secure stability and improve quality. Therefore, as a system similar to the aviation component management system, it should be thoroughly managed for urban aviation components.
        4,000원
        92.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the Defense Advanced Research Projects Agency(DARPA) in the United States is studying a new concept of war called Mosaic Warfare, and MUM-T(Manned-Unmanned Teaming) through the division of missions between expensive manned and inexpensive unmanned aircraft is at the center. This study began with the aim of deriving the priority of autonomous functions according to the role of unmanned aerial vehicles in the present and present collaboration that is emerging along with the concept of mosaic warfare. The autonomous function of unmanned aerial vehicles between the presence and absence collaboration may vary in priority depending on the tactical operation of unmanned aerial vehicles, such as air-to-air, air-to-ground, and surveillance and reconnaissance. In this paper, ACE (Air Combat Evaluation), Skyborg, and Longshot, which are recently studied by DARPA, derive the priority of autonomous functions according to air-to-air collaboration, and use AHP analysis. The results of this study are meaningful in that it is possible to recognize the priorities of autonomous functions necessary for unmanned aircraft in order to develop unmanned aerial vehicles according to the priority of autonomous functions and to construct a roadmap for technology implementation. Furthermore, it is believed that the mass production and utilization of unmanned air vehicles will increase if one unmanned air vehicle platform with only essential functions necessary for air-to-air, air-to-air, and surveillance is developed and autonomous functions are expanded in the form of modules according to the tactical operation concept.
        4,000원
        93.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fungi have been known as an irritant or causal agent of asthma. Thus, information on their concentration and diversity in indoor air of asthmatic patient’s houses is valuable for the management of these micro-organisms. The present study was performed to investigate fungal concentration and diversity in indoor air of resident spaces in two adult patient’s houses in winter. Air samples were collected in February of 2018 from living rooms and bedrooms of two asthma patients’ houses located in two different places in Incheon city using an impaction method. The average concentrations of airborne fungi did not exceed the 500 CFU/m3 level which is recommended by the Enforcement Managements of the Indoor Air Quality, Ministry of Environment, Korea. A total of four genera and 23 species were identified based on morphological and molecular methods. Aspergillus and Penicillium were two major genera. Aspergillus pseudoglaucus and Penicillium citrinum were commonly found between the two patient’s houses. Among the identified fungi, three species, Aspergillus venenatus, Penicillium jamesonlandense, and Penicillium salami were found to be unrecorded species in Korea. The morphological and molecular characteristics of these three unrecorded species were described. Since these species produce spores well and a lot, they are considered to be a species that needs management. This study provides basic information on the fungi for indoor air quality management in the living spaces of asthma patients in winter in Korea.
        4,000원
        94.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 도심항공모빌리티(UAM) 상용화에 앞서 도심 내 항공 교통수단 관련 산업에 대한 연구개발 중요성이 급격히 증가하고 있다. 도심항공모빌리티(UAM) 환경을 조성하기 위해서 핵심 항공 이동 수단 비행체인 개인용 항공기 (PAV) 기체에 관한 연구가 수행되고 있으나, 탑승자 관점의 연구가 상대적으로 부족한 상황이다. 특히 PAV는 탑승 자의 새로운 생활공간으로 활용될 것으로 예상되기 때문에 탑승자의 실내행위를 지원하는 실내공간 설계를 위해서 는 PAV 기체에서 발생하는 물리적 요소가 인체에 미치는 영향에 관한 연구가 필수적으로 이루어져야 한다. 이에 본 연구의 목적은 PAV의 공중 운항 특성으로 인해 인체에 영향을 주는 제약 요소를 도출하고, 이러한 제약 요소가 실내행위를 수행하는 탑승자 인체에 미치는 영향을 파악하는 것이다. 본 연구 결과, 항공 이동 수단 비행 기체 PAV 는 4,000ft 이하에서 운항해야 하는 기준에 따라, 운항고도에 따른 제약 요소는 소음, 진동, 저주파 운동에 의한 멀미 로 나타났다. 이러한 제약 요소가 실내행위에 영향을 미친다는 관점에서 PAV에서 행할 수 있는 실내행위를 자율주 행 자동차, 비행기, PAV 컨셉 사례를 활용하여 도출하고 인체에 미치는 영향과 수준을 고려하여 실내행위 지원을 위한 제약 요소 권장기준을 설정하였다. 또한 실내행위 지원을 위한 제약 요소의 인체 영향 수준을 감소시키기 위해 서는 시트의 형태 및 내장기능(진동 저감 기능, 온도조절, LED조명 등), 개인 좌석별 지향성 스피커를 활용한 외부소 음 감소, 소음과 진동 감소를 위한 내장재 등을 실내공간 설계에 반영해야 함을 제시하였다. 본 연구는 PAV 실내행 위에 영향을 주는 제약 요소를 도출하였고, 인체에 미치는 영향 수준을 확인하였으며, 추후 PAV 실내 설계 시 기초 자료로써 활용할 수 있다는 점에서 의미가 있다.
        5,200원
        95.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This work using first-principles theory proposed PdN3- doped CNT ( PdN3-CNT) as a potential gas sensor for detection of NO, NO2 and O3 in the air insulated equipment, to evaluate its operation status. Results indicate that the PdN3- CNT behaves chemisorption upon three gas species, with adsorption energy (Ead) of − 2.15, − 1.91 and − 1.96 eV, and charge-transfer (QT) of − 0.141, − 0.325 and − 0.419 e, respectively. The band structure (BS) and density of state (DOS) analysis reveal that the gas adsorptions cause remarkable deformations in the electronic property of the PdN3- CNT, leading to the increase of the bandgap for the gas adsorbed systems and verifying the strong binding force of the bonded atoms from the orbital DOS. Combined with the results by frontier molecular orbital theory, we presume that PdN3- CNT is a promising sensing material to be explored as a resistance-type gas sensor for detection of NOx with higher electrical response upon NO. It is our hope that our theoretical assumption could be further studied and realized in the following experiential research, which would be meaningful to propose novel sensing candidate in the field of electrical engineering to guarantee the safe operation of the air insulation equipment.
        4,000원
        96.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Indoor air quality management is essential for a healthy life. However, it is difficult to perceive, detect, and monitor the level of indoor air pollution and this means that it is possible to be exposed to more pollution indoors than outdoors. In this study, in order to derive effective indoor air quality management measures, public perceptions and behavioral characteristics regarding indoor particulate matter and air quality management methods were investigated through a survey of 1,000 people. Based on the survey, it was found that most of the respondents had a negative perception of the indoor air quality of their residence, and natural ventilation was the most used method for indoor air quality management. Although the frequency of use of air quality management devices such as air purifiers and mechanical ventilation systems was relatively low, their effect regarding air quality management was positively perceived. In particular, the results of survey indicated that respondents of families which included members with fragile health engaged in more active behavior regarding in indoor air quality management than those respondents whose family members had no health issues and that the former have used air quality management devices more frequently. Therefore, it is necessary to develop proper guidelines to encourage more people to actively participate in improving indoor air quality.
        4,000원
        97.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High concentrations of fine particles are increasingly being detected due to inflows from abroad and local emission sources in Korea. As most people spend about 90% of their time indoors, the use of indoor air cleaners has grown significantly as they are now thought to be essential items. In this study, the noise, power consumption, and clean air delivery rate (CADR) of commercial air cleaners were analyzed according to the structural shape of the air cleaners. Analyses were performed based on the experimental results of 249 cases for air cleaners certified by Korea Air Cleaning Association. The air cleaners with front inlet and upper outlet air flow direction, which currently account for the highest market share, were found to have the highest noise per CADR (dB(A)/(m3/min)). On the other hand, the air cleaners with the inlet and outlet air flow in the same horizontal direction were found to have lowest noise per CADR than other structures.
        4,000원
        98.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Airborne bacteria are expected to float in the mushroom cultivation house, as it is a special environment with high humidity and high temperatures. Their concentration and diversity in the indoor air of the cultivation house could effect the health of farmers and the quality of mushrooms. To examine whether microbiota of airborne bacteria change from year to year, we measured the indoor temperature, humidity, and airborne bacterial concentration from mushroom cultivation houses located in six regions in Korea from 2020 to 2021, and isolated and identified airborne bacteria. The surveyed data were compared and the bacterial diversity of the 1st year and the 2nd year were determined. Based on the average temperature and humidity data surveyed, it can be seen that the temperature and humidity environment in the cultivation houses is such that bacteria can easily reproduce. It was observed that the temperature inside the cultivation houses tends to be higher or lower depending on the season and correlates with the temperature outside the cultivation houses. In the first year survey, 32 species of 20 genera were identified, and in the second year survey, bacteria belonging to 29 species of 22 genera were identified. Among them, the most detected species were all species belonging to the genus Bacillus. There were only three species (Bacillus altitudinis, Brevibacterium frigoritolerans, and Staphylococcus epidermidis) that were continuously isolated in common. Our results showed that the species of floating bacteria greatly vary from year to year even for the same cultivation houses.
        4,000원
        99.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, indoor air quality indices (IAQI-C and IAQI-E) were developed for child care centers and elderly care centers based on health effects, and compared to the air quality index (CAI) for outdoor atmosphere. In addition, composite indices that integrate individual indices for each pollutant were developed to quickly and conveniently recognize the current air quality. Among all data, 71.2% and 35.6% belonged to the grades 'Good' and 'Moderate' for child care centers and elderly care centers, respectively. This assessment is more stringent than the CAI's criteria.
        4,000원
        100.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An odor is referred to or described as an unpleasant smell that creates a disagreeable atmosphere and may impinge on the quality of life of people. Most of the odors that stimulate the human sense of smell and engender feelings of discomfort and disgust are odors mixed with various chemicals substances. Among designated odor substances, acetaldehyde, propionaldehyde, butyraldehyde, n-valeraldehyde, and iso-valeraldehyde may cause an irritating and sour sensation and give rise to headache, dizziness, vomiting, and unconsciousness. These aldehyde substances are mainly discharged in high concentrations from food chemicals, petrochemicals, and printing industry sources. The odor control technologies applied to prevent odors from aldehydes are absorption, adsorption, as well as biological methods and combustion methods. The threshold concentrations of aldehydes are low so that odors can be easily experienced even at very low concentrations. It is not easy to control aldehydes due to their particular physicochemical properties and because aging and poor management of the odor prevention technology is usually only available. In this study, trends with regard to research efforts on the development of technology that is effective in treating aldehydes were summarized.
        4,500원
        1 2 3 4 5