검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 230

        121.
        2008.12 구독 인증기관 무료, 개인회원 유료
        The present study purposed to establish high school male students’ criterionreferenced standards for the Youth Physical Fitness Awards Program in order to suggest standard physical strength levels to be achieved by high school male students in the events
        6,300원
        122.
        2008.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The reliability prediction and evaluation for general electronic components are required to guarantee in quality and in efficiency. Although many methodologies for predicting the reliability of electronic components have been developed, their reliability might be subjective according to a particular set of circumstances, and therefore it is not easy to quantify their reliability. In this study reliability prediction of electronic components, that is the interface card, which is used in the CNC(Computerized Numerical Controller) of machine tools, was carried out using PRISM reliability prediction specification. Reliability performances such as MTBF(Mean Time Between Failure), failure rate and reliability were obtained, and the variation of failure rate for electronic components according to temperature change was predicted. The results obtained from this study are useful information to consider a counter plan for weak components before they are used.
        4,000원
        123.
        2008.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to measure intrarater and interrater reliability of a portable digital pressure algometer. Fifty healthy subjects were recruited for this study. Pressure pain thresholds of splenius capitis, levator scapular, and upper trapezius muscles were measured using by FPK algometer and portable digital pressure algometer. Three trials were done on each subject by two examiners. Intraclass correlation coefficients (ICCs) were used to determine the reliability of each measure. The intrarater reliability of the FPK algometer was good and excellent (ICC .63~.79) and the interrater reliability was poor and good (ICC .15~.57). The intrarater reliability of a portable digital pressure algometer was excellent (ICC .75~.86) and the interrater reliability was poor and good (ICC .35~.61). This result suggests that the intrarater reliability and interrater reliability of a portable digital pressure algometer were better than an FPK algometer.
        4,000원
        124.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        신뢰성 기반 형상 최적화(RBDO)글 위한 기술은 한정된 정보로 인한 인식론적 불확실성을 다룰 수 있는 베이지안 접근에 근거하여 발달된다. 최근까지, 전통적인 RBDO는 측정 데이터가 무한히 많아서 확실한 확률정보를 알고 있다는 가정 하에 실행되었다. 하지만 실제로는, 부족한 데이터로 인해 기존의 RBDO 방법의 유용성을 떨어뜨린다. 본 연구에서는, 확률정보의 불확실성을 인식하고, 따라서 산포를 갖게 되는 시스템 신뢰도의 확률 분포에서의 신뢰수준의 하한 값을 고려하기 위해 '베이지안 신뢰성'이 소개된다. 이런 경우, 베이지안 신뢰성 해석은 기존 신뢰도 해석의 이중 해석을 요구하게 된다. 크리깅 기반 차원 감소 방법(KDRM)은 신뢰도 해석을 위한 새로운 효율적인 방법으로써 사용되며, 제시된 방법은 몇 가지 수치예제를 사용하여 설명된다.
        4,000원
        125.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적: 자유공간과 제한된 공간에서 측정한 Gradient AC/A비를 비교 분석하여 3가지 사위측정법의 신뢰도를 평가하였다. 방법: 2006년 9월 1일부터 2009년 9월 30일까지 서울에 거주하며 본 연구의 취지에 동의한 전신질환과 안질환이 없는 20세 이상의 성인 67명(26.61±2.56세)(남자 32명, 여자 35명)을 대상으로 선정하였으며, 굴절이상 수술 또는 사시 수술 병력이 있는 자는 대상자에서 제외하였다. 자동굴절검사(KR-7100P, Topcon Co.)와 표준 자각식 굴절검사로 원거리 굴절 이상도를 측정하였고, 포롭터(Shin-Nippon BR-7), 시력표투영기(Topcon ACP-7), 시험테(FM580), 렌즈 홀더(Gulden Ophthalmics co.), 프리즘바(Gulden co.), 낱개 프리즘, MIM Card(Bernell co.) 등을 이용하여 본그래페법, 마독스봉 및 수정 토링톤법에 의한 사위도 및 Gradient AC/A비를 측정하였다. 결과: 등가구면 굴절이상도는 우안 -2.79±2.56D, 좌안 -2.69±2.65D였고, 난시도는 우안 -0.80±0.49D, 좌안 -0.93±0.71D였다. 대상자 전체의 사위도는 원거리가 -0.31±1.24△, 근거리가 -1.67±4.51△이었다. 포롭터를 이용한 사위도는 VG(distance) -0.78±2.14△, MR(distance) -0.35±1.85△, MT(distance) -0.40±1.81△, VG(near) -2.63±4.64△, MR(near) -1.69±4.80△, MT(near) -1.78±4.52△이었다. 시험테로 측정된 사위도는 VG(distance) -0.69±1.96△, MR(distance) -0.32±1.77△, MT(distance) -0.40±1.82△, VG(near) -2.31±4.18△, MR(near) -1.60±4.51△, MT(near) -1.68±4.20△이었다. 제한된 공간에서 ±1D를 이용하여 측정한 Gradient AC/A비는 VG 3.32±0.81△, MR 3.07±0.61△, MT 2.74±0.29△이었고 자유공간에서 측정한 Gradient AC/A비는, VG 3.27±0.73△, MR 3.11±0.64△, MT 2.57±0.26△이었다. 각 측정법의 신뢰도를 비교한 결과, 95% 일치구간은 포롭터를 이용한 VG 측정법이 3.04로 가장 넓었고 시험테를 이용한 MT 측정법이 1.42로 가장 좁아 신뢰도가 높았다. 결론: 이상으로부터 제한된 공간과 자유 공간에서 측정된 사위도는 약간의 차이가 있었으나 임상적으로 유의하지 않은 것으로 판단되었고, Gradient AC/A비를 기준했을 때 VG 측정법과 MR 측정법보다는 MT 측정법의 신뢰도가 높은 것으로 사료된다.
        4,000원
        126.
        2008.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 본 연구는 LOTCA-G를 한국어로 번역 후 문화적으로 표현에 차이가 있는 문항을 한국 실정에 맞게 수정보완해 그것의 타당도 및 신뢰도를 알아보고, 우리나라 65세에서 90세 노인에게 확대 적용할 수 있는 근거를 제시하고자 시행하였다.연구방법 : 한국 문화를 고려하여 수정한 LOTCA-G의 타당도 조사는 성인작업치료 임상경력 3년 이상의 작업치료사에게 검토를 의뢰한 내용 타당도(content validity)를 실시하였고, 신뢰도 조사는 정상 대조군 40명과 임상 환자군 40명을 대상으로 재검사법(test-retest method)을 실시하였다.결과 : 내용 타당도는 양호했고, 건강 대조군과 임상 환자군의 검사-재검사 신뢰도와 검사자간 신뢰도, 항목별 내적 일치도, 연령 군별 신뢰도 모두 만족할 수준이었다. 한국 문화를 고려하여 수정한 LOTCA-G는 그 해당 연령뿐 아니라 65세에서 70세 사이 대상도 함께 신뢰도 조사한 결과 만족할 수준이었다.
        4,200원
        128.
        2008.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to examine the validity and reliability of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)-VA3.0 in patients with hip and knee osteoarthritis (OA). The sample consisted of 301 patients who had received treatments at the physical therapy units of 5 medical institutions in Andong City in june 2006. Questionnaires on the WOMAC were recruited by 12 physical therapists. The internal structure and reliability of the scales were evaluated by means of item-internal consistency (Cronbach's alpha coefficient: ), item-discriminant validity, and Pearson's relation coefficient. To explore construct validity, we conducted a principal component factor analysis with varimax rotation analysis. The criterion for factor extraction was an eigenvalue >1.0. The average age of the patients was 62.1 years. All WOMAC subscales (pain, stiffness, and physical function) were internally consistent with Cronbach's coefficients of .81, .91, and .80, respectively. The internal consistency reliability of item-each scale were also internally consistent with Cronbach's coefficient of .89 (Pearson's correlation coefficient: .71~.84), .93 (.89~.91), and .96 (.67~.91), respectively. However, high correlation was found among 3 items (.66~.83, .66~.67, and .67~.83), so the item-discriminant validity was low ( coefficient: .81, .91, .80, respectively). The construct validity by factor analysis was low because it was not consistent With WOMAC-VA3.0. In conclusion, the results reported here confirm the reliability of the WOMAC in patients with OA of the hip and knee. The collection of information on the hip and knee osteoarthritis using this instrument was acceptable to patients. A further prospective multi-center study will be necessary to prove the construct validity.
        4,000원
        129.
        2008.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 건강기능식품에 대한 소비자 연구를 통하여 신뢰도를 향상시키기 위한 표시 제도를 제안하기 위해 수행되었다. 소비자가 쉽게 건강기능식품을 확인할 수 있도록 공모를 통하여 인증마크를 개발하고 소비자 조사를 실시하였다. 조사대상자는 대도시, 중소도시 등 2000명으로 하여 1:1 면접조사를 실시하였다. 조사결과 건강기능식품 인증마크의 필요도가 매우 높았고, 텍스트 형태보다 텍스트/그래픽이 혼합된 형태의 영양·기능정보의 신뢰도가 높았다. 또한 인체에 작용하는 기전을 포함한 영양·기능정보가 소비자의 신뢰도를 높이는 데 도움이 되는 것으로 조사되었다. 따라서 건강기능식품 인증마크는 소비자로 하여금 제품을 선택하는데 도움을 줄 수 있을 것으로 사료되며, 또한 건강기능식품의 신뢰도를 높일 수 있는 표시제도의 개선에 기여할 것으로 사료된다.
        4,200원
        130.
        2008.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Pediatric Balance Scale (PBS) is a modified Berg's Balance Scale developed as a balance measure for school-aged children with mild to moderate motor impairments. The purpose of this study was to determine the inter-examiner reliability of the Korean version of PBS when applied to children with developmental delays. In this study, PBS was administrated to a total of 79 children with developmental delays (17 with global developmental delay, 31 with cerebral palsy, and 31 with mental retardation) in the Seoul Community Rehabilitation Center. Two pediatric trained physical therapists with longer than 13 year of clinical experience scored the children's performance blind, while replaying videotaped data. The inter-examiner reliability was statistically determined by intraclass correlation coefficients (ICCs). The results of this study revealed that the Korean version of PBS seems to have high inter-examiner reliability when applied to children with movement disorders such as global developmental delay (ICC=.96) and cerebral palsy (ICC=.97); however, it has relatively lower inter-examiner reliability (ICC=.78) for children with developmental delay secondary to mental retardation. therefore, the results support that the Korean version of the PBS could be a useful clinical measurement to assess the balance skills for children with developmental delay who have an adequate level of cognition to enable them to fol1ow the verbal instructions to complete the test.
        4,000원
        131.
        2008.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The self-report measure is a useful tool for evaluating self-recognized disability and difficulty in daily living activities. Although many studies and clinics used the Neck Pain and Disability Scale (NPDS) for measuring neck pain and functional impairment, there has not been much adaptation of this for use with Korean patients. The purpose of this study was to establish the reliability and validity of NPDS among Korean neck pain patients. Fifty-five subjects (32 males, 23 females) with neck pain enrolled in this study. They completed standardized self-administered questionnaires. The NPDS measures pain intensity; its interference with vocational, emotional, recreational, social, and functional aspects of living; and the presence and extent of associated factors. Reliability was determined by the intraclass correlation coefficient (ICC) and Cronbach's alpha for internal consistency. Validity was examined by correlating the NPDS scores to the Visual Analog Scale (VAS) score. The test-retest reliability of the translated versions of the NPDS was good ICC (2,1)=.86 (95%CI .76~.92). Cronbach's alpha value for NPDS was found to be .93, and this was statistically significant (p<.05). The criterion-related validity coefficient was .79 (p<.Oll. We conclude that the Korean version of NPDS has been shown to be a reliable and valid instrument for the assessment of neck pain. Successful linguistic and cultural translation will admit appropriate cross-cultural comparison for clinical analysis. Therefore, this study can be expected to be used as an adequate evaluation scale for neck pain related studies and treatments.
        4,000원
        132.
        2007.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        이 논문은 사용후핵연료 차세대관리공정(ACP)에 사용되는 주요부품에 대한 방사선영향에 대하여 다룬다. 평가대상 부품으로는 중요도가 높은 것들 중에서 선택하였는데, AC 서보모터, 포텐쇼미터, 열전대, 가속도계, CCD 카메라를 그 대상으로 하였다. AC 서보모터의 경우 ACP 핫셀 내 조작기에 여러개가 사용되고 있고, 공정장치의 일부에 사용되고 있다. 포텐쇼미터는 조작기 관절의 절대 각도를 측정하기 위해 사용된다. 열전대는 금속전환장치 등의 반응기 온도 측정을 위해 사용된다. 가속도계는 탈피복시 발생하는 이상을 사전에 감지하기 위한 용도로 탈피복장치에 부착되어 있고, CCD 카메라는 조작기와 함께 공정 휴지기간에 영상 In-situ 이상감시를 하기 위한 용도로 사용된다. 다양한 방사선 중 감마선은 전기, 전자 및 로봇 부품에 가장 치명적이라고 알려져 있으므로 본 연구에서는 Co-60선원을 사용하는 감마조사시설을 이용해 방사선 영향을 평가하였다. 방사선조사결과 CCD 카메라를 제외한 다른 부품들은 방사선에 매우 강인한 특성을 보였다. 누적조사선량에 대한 각 대상 부품의 고유한 특성변화 데이터를 얻었고, 대상 부품의 성능을 보장할 수 있는 기준인 손상분기점에 대한 평가 자료를 얻을 수 있었다
        4,600원
        133.
        2007.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 본 연구는 뇌졸중 환자의 Hemiplegic Motor Behavior Test(HMBT)에 대한 타당도와 신뢰도를 알아보고자 하였다. 연구방법 : 본 연구를 위하여 국립재활원에 입원한 34명의 뇌졸중 환자를 대상으로 Hemiplegic Motor Behavior Tests(HMBT)가 임상적으로 뇌졸중 환자의 운동기능을 평가하기에 적합한지 알아보고자 하였다. 기준관련 타당도 분석을 이용하여 일상생활동작 수행 정도(Modified Barthel Index: MBI), 기능적 독립 수준(Modified Rankin Scale: MRS)과 상지기능 수행 평가 도구인 Brunnstrom Stage Scale(BSS), Hand Movement Scale(HMS), 자세조절(Postural Assessment Scale for Stroke: PASS-MP/CP), 체간 조절(Trunk Control Test: TCT)과의 피어슨(Pearson correlation)상관관계를 알아보았다. HMBT의 측정자내 신뢰도(Inter-rater reliability)와 측정자간 신뢰도(Intra-rater reliability)를 알아보기 위하여 Kappa계수와 Intraclass Correlation Coefficient(ICC)를 구하였으며, HMBT항목들의 내적 일치도를 알아보기 위하여 Cronbach's alpha coefficient를 구하였다. 결과 : HMBT의 U/E, H/F에 대한 측정자내 신뢰도는 각각 Kappa=.960~.950, ICC=.995~.994이었으며, 측정자간 신뢰도는 Kappa=.959~.918, ICC=.990~.986으로 신뢰도는 높은 것으로 나타났고 내적일치도는 Cronbach's alpha=.931로서 매우 높게 나타났다. HMBT는 MBI(r=.64~.66), MRS(r=-.63~.71), HMS(r=.82), BSS-Arm/Hand(r=.81~.82)와도 높은 상관관계를 보였고 PASS-MP/CP(r=.42~.52), TCT(r=.55~.64)간에 유의한 상관관계가 있는 것으로 나타나 신뢰도와 타당도가 높은 것으로 나타났다. 결론 : 본 연구 결과에서 뇌졸중 환자를 위한 HMBT는 MBI, HMS, BSS, PASS-MP/CP, TCT, MRS에서 유의한 상관관계가 있는 것으로 나타났으며, 높은 타당도와 신뢰도 및 내적 일치도를 보여 뇌졸중 환자의 실제적인 임상 평가도구로 활용이 가능할 것이다.
        4,200원
        134.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
          This paper presents the conceptual framework for estimating and predicting system’s susceptibility to failure as function of condition parameter value which is representing the current status of performance measure using on-line performance reliability.
        4,000원
        135.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to determine reliability and validity of the Neck Disability Index (NDI) now in use for the first time in neck pain patients of Korea. Fifty subjects (26 males and24 female) with neck pain enrolled in the study. They completed a standardized self-administered questionnaire that include pain intensity, personal care, lifting, reading, headaches, concentration, work, driving, sleeping and recreation. Reliability was determined by intra-class correlation coefficient (ICC) and Cronbach's alpha by internal consistency. Validity was examined by correlating the NDI scores to the Visual Analog Scale (VAS) score. The Test-retest reliability of the translated versions of the NDI was good ICC (2,1) = .90 (95%CI .85 .95). Cronbach's alpha value for NDI was found to be .95 and this was statistically significant (p<.05). The criterion-related validity coefficients was .72 (p<.01). We conclude that the Korean version of NDI has shown to be a reliable and valid instrument for the assessment of neck pain.
        4,000원
        136.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to evaluate inter-rater reliability of the amplitude and first knee extension angles in deep tendon reflex test by using an electrical hammer. Twenty-five healthy adults participated in the study. Compound muscle action potential is elicited by tapping the knee tendon with an electrical hammer in deep tendon reflex tests. The amplitude and knee extension angle were simultaneously measured. The mean value of the amplitude and the knee extension angles through three time trials for each tester, are used for determining the inter-rater and Intra-class Correlation Coefficients (ICCs) reliabilities. According to the results, the ICCs of the amplitude is .280 and that of the knee extension angle is .789. Pearson correlation coefficients of the amplitude of the action potential and the knee extension angles are .685, showing significant statistically moderate correlation. Inter-rater reliability in the amplitude was not significant. More objective and quantitative deep tendon reflex tests should be done to obtain higher reliability in further studies.
        4,000원
        138.
        2007.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to examine inter- and intra-examiner reliability of the sacroiliac joint (SIJ) anatomical landmarks palpation. Two physical therapists and one doctor specializing in rehabilitation examined 22 asymptomatic subjects. They examined anterior superior iliac supine (ASIS), posterior superior iliac supine (PSIS) and iliac crest (IC). For the assessment of intra-examiner reliability, 3 examiners repeated the measurements 3 times over a 2-week interval. Kappa (Kg) yielded intra-examiner reliability that ranged between slight to fair for the ASIS (Kg=.06 to .26; mean Kg=.19), and slight for the PSIS(Kg=-.04 to .18; mean Kg=.07) and slight to fair for the IC (Kg=.06 to .32; mean Kg=.21). Inter-examiner reliability was slight (ASIS Kg=.13; PSIS Kg=.05; IC Kg=.14). These results suggest that the reliability of the assessing SIJ anatomical landmarks using palpation and observation as an indication of SIJ dysfunction still remains questionable. Before this test can be relied upon as an accurate indicator of SIJ dysfunction, it must undergo further research. This further research needs to examine not only reliability, but also validity, sensitivity and specificity.
        4,000원
        139.
        2007.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Muscle tone (stiffness/hardness) or muscle compliance changes during muscle contraction. The purposes of this study were to assess the intrarater and interrater reliabilities of the Myotonometer®, electronic device that quantifies muscle tone. Two raters used the Myotonometer to assess the right bicep brachia and quadriceps muscles of 30 voluntary persons without any orthopedic or neurological problems (age range, 18~21 yrs). Muscles were measured in a relaxed state and during brief sustained voluntary maximal isometric contraction. Intrarater correlation coefficients were calculated for each muscle and for each condition (relaxed and contracted). Intrarater reliabilities (intraclass correlation coefficients, ICCs) ranged from .778 to .954, relaxed, biceps brachia), .926 to .963 (contracted, biceps brachia), .935 to .990 (relaxed, quadriceps) and .679 to .952(contracted, quadriceps). Interrater reliabilities ranged from .652 to .790 (relaxed, biceps brachii), .813 to .907 (contracted, biceps brachii), .831 to .950 (relaxed, quadriceps) and .849 to .937 (contracted, quadriceps). Myotonometer measurements had high to very high intrarater and interrater reliability for measurements of the biceps brachia and quadriceps muscles.
        4,000원
        140.
        2007.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        임상에서 주로 사용되고 있는 서로 다른 각막형태검사기기(corneal topographer)의 신뢰도와 정확도를 비교 분석하였다. 정상안의 양안에 OrbscanIIz Slit-scan system, Oculus topography system, Eyesys corneal analysis system 및 Humphrey Atlas corneal topography system을 이용하여 각막중심부의 곡률반경(apical radius), simulated K-reading과 이심률을 측정하였다. 47명(94안)을 대상으로 동일한 검사자 에 의한 두 번의 독립된 측정과 서로 다른 검사자에 의한 측정으로 신뢰도를 비교하 였고, 수동각막곡률계를 기준으로 동일한 검사자가 19명(38안)을 대상으로 두 번의 독립된 측정을 수행하여 정확도를 구하였다. 각각의 기기에서 동일한 검사자가 반복 측정한 값은 유의한 차이가 없었고, 서로 다른 검사자에 의한 측정값 사이에서도 유 의한 차이가 없었다. 신뢰성계수(COR)가 가장 높은 기기는, apical radius는 Oculus (COR = 0.043), flatter simulated K-reading은 Eyesys(COR = 0.034), steeper simulated K-reading은 Oculus(COR = 0.048), eccentricity는 Eyesys(COR = 0.024)였다. 신뢰성 측정변수에서 Oculus와 Eyesys가 OrbscanIIz와 Humphrey Atlas보다 신뢰도가 좀더 높게 나타났다. 수동각막곡률계를 기준으로 한 flatter K-reading 및 steeper Kreading에 대한 정확성계수는 Orbscan IIz에서 각각0.069과 0.075, Oculus는 0.047과 0.075, Eyesys는 0.047과 0.068 및 Humphrey Atlas는 0.066과 0.078이었다. 4가지 기 기 모두 steeper K-reading보다 flatter K-reading의 정확도가 더 높았다. 4가지 각막 형태검사기기 사이에서 신뢰도와 정확도는 유의한 차이가 없었다.
        4,900원