검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 55

        1.
        2023.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Hydrogen is considered as one of the most promising future energy carriers due to its noteworthy advantages of renewable and high calorific value. The long-term storage of liquid hydrogen with low heat leakage is essential for future deep space exploration. Because of low critical temperature and volatility, liquid hydrogen tank poses severe requirements to multi-layer insulation (MLI). In order to reduce heat leak into tank, vapor cooled shield (VCS) was set up to cool MLI by retrieving the heat of discharged cryogenic gas hydrogen. This paper presents an parametric study on insulation system in liquid hydrogen storage vessel with MLI and VCS. Thermal model was developed, and heat transfer analysis by varying VCS position was conducted. Temperature and heat flux distributions along time passing were derived, and effect of VCS position on insulation performance was investigated.
        4,000원
        3.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : In this study, we propose a mini-trench method, which involves using warm mix Guss mastic asphalt as a backfill material and an installation temperature of 160 ℃. The method is verified via a heat transfer analysis of a pavement using the finite element method. METHODS : First, the density, thermal conductivity, and specific heat required for heat transfer analysis were determined based on previous studies. Subsequently, the boundary conditions for convection and radiation to perform the heat transfer analysis were determined. The pavement temperature, which is the initial condition of the analysis, was determined based on the summer pavement temperature distribution using the temperature prediction program of the Korean pavement Research Program. Heat transfer analysis was performed by determining the temperature of the backfill material based on 160 °C and 200 °C for the heat load temperatures. The temperature change was observed on the backfill surface, and the temperature change of the conduit was observed directly. RESULTS : When the pavement surface temperature for traffic opening is 50 °C, the backfill thickness ranges from 50 to 250 mm, the warm mix Guss mastic asphalt requires 2 h to 5 h, 15 min until traffic opening, and the hot mix Guss mastic asphalt requires 2 h, 30 min to 6 h, 40 min until traffic opening. The limit temperature of the conduit evaluated based on KS C 8454 shows that the warm mix Guss mastic asphalt does not satisfy the standard when the backfill concrete cover is 50 mm thick, whereas the hot mix Guss mastic asphalt does not satisfy the standard when the concrete cover is 50 and 100 mm thick. CONCLUSIONS : The backfill depth of the mini-trench using warm mix Guss mastic asphalt as a backfill material should be less than 100 mm, considering the traffic opening time. Meanwhile, the thickness of the backfill concrete should be 100 mm or less.
        4,000원
        4.
        2022.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Research is being actively conducted on the continuous thin plate casting method, which is used to manufacture magnesium alloy plate for plastic processing. This study applied a heat transfer solidification analysis method to the melt drag process. The heat transfer coefficient between the molten magnesium alloy metal and the roll in the thin plate manufacturing process using the melt drag method has not been clearly established until now, and the results were used to determine the temperature change. The estimated heat transfer coefficient for a roll speed of 30 m/min was 1.33 × 105 W/m2·K, which was very large compared to the heat transfer coefficient used in the solidification analysis of general aluminum castings. The heat transfer coefficient between the molten metal and the roll estimated in the range of the roll speed of 5 to 90 m/min was 1.42 × 105 to 8.95 × 104 W/m2·K. The cooling rate was calculated using a method based on the results of deriving the temperature change of the molten metal and the roll, using the estimated heat transfer coefficient. The DAS was estimated from the relationship between the cooling rate and DAS, and compared with the experimental value. When the magnesium alloy is manufactured by the melt drag method, the cooling rate of the thin plate is in the range of about 1.4 × 103 to 1.0 × 104 K/s.
        4,000원
        5.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to environmental pollution, regulations on existing petroleum-based fuels are increasing day by day. LNG is in the spotlight as an eco-friendly fuel that does not emit NOx or SOx, but its boiling point is -163°C, so it needs to be handled with care. Materials that can be used at the above temperature are defined by IMO through the IGC Code. Among them, 9% nickel steel has great advantages in yield strength and tensile strength under cryogenic conditions, but it is difficult to use in arc welding such as FCAW for various reasons. This study is a study to apply fiber laser welding to solve this problem. As a previous study, this study conducted a study to find a welding heat source. After performing bead on plate welding, the optimal heat source was derived by analyzing the shape of the bead and adjusting the parameters of the heat source model. In this case, by applying the multi-island genetic algorithm, which is a global optimization algorithm, not the intuition of the researcher, accurate results could be derived in a wide range.
        4,000원
        6.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The enhancement of heat transfer in cooling system of cylindrical lithium-ion battery pack is numerically investigated by installing fins on the cooling plate. Battery Design StudioⓇ software is used for modeling electro-chemical heat generation in the battery and the conjugated heat transfer is analyzed with the commercial package STAR-CCM+. The result shows that installing fins on the cooling plate increases the convective heat transfer on the surface and thus lowers the maximum temperature of the battery pack. As the length and thickness of the fins increase, heat transfer in the battery pack improves. Considering the geometry and airflow of the battery pack, the optimal values for the length and thickness of the fin are both 2mm. As the convective heat transfer coefficient of the surface increases, the maximum temperature of the battery pack is greatly reduced and the temperature gradient is greatly improved.
        4,000원
        7.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the heat transfer performance of nanofluids is predicted by numerical analysis methods. The nanoparticles used in this study is SiO2, with concentrations of 1, 2, 3vol.%, and the base fluid is water. Reynolds number of nanofluids ranges from 10,000 to 50,000. A numerical study on the heat transfer characteristics of nanofluid was conducted using a single-phase model. The temperature of the fluid entering from the inlet of the tube is 293.15K. A constant heat flux of 31,650W/m2 was applied at the wall, and the thickness of the wall was ignored. Heat transfer coefficients, thermal conductivity and Nusselt number were selected as indicators for comparing heat transfer performance of nanofluids. As the nanofluid concentration increases, the temperature and velocity distribution by the cross section of the coil tube and straight tube increased. As the Reynolds number increases, temperature difference between inner direction and outer direction reduced in coil tube. For straight tube, the temperature difference between the wall and the center of the tube also decreased.
        4,000원
        8.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        While the vehicle has a wide front view, making it easy to recognize obstacles while driving, the rear side has a narrow view and the inconvenience of having to turn its head to check. A side mirror developed to address this discomfort is mounted outside the front door of a passenger car and used to identify rear objects. In this study, heat transfer analysis was performed and analyzed in order to obtain optimal defrost conditions using regression analysis method for removing mirror condensation and frost. As a result of this study, the coefficient of determination, R2, which represents the regression to the total variation through regression analysis, showed a good reliability of 85.3%. Comparing the predicted and interpreted values of the maximum temperature distribution in the regression equation established in this study, it was included in the 95% confidence interval, enabling the prediction of the maximum temperature distribution over the heat conduction time.
        4,000원
        9.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this analysis, the analytical model was verified through the normal mode analysis of the piston for the 2.9 liter IDI (indirect injection) engine. Heat transfer analysis was carried out by selecting two cases of applied temperature using the validated model. The first case was a condition of 350℃ on the piston upper surface and 100℃ on the piston body and inner wall. In the second case, the conditions were set to give a temperature of 400℃ on the upper surface of the piston and 100℃ on the piston body and the inner wall. In addition, the temperature distribution due to heat transfer was obtained for the pistons with boundary conditions of two cases, and then the thermal stress distribution due to thermal expansion was obtained using the input. Using this analysis result, the thermal stress caused by thermal expansion due to the thermal conduction of the piston is examined and used as the basic data for design.
        4,000원
        10.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The improvement of heat transfer in water cooling passage of lithium-ion battery is numerically studied by employing trapezoidal vortex generators. Battery Design StudioⓇ software is used for modeling electro-chemical heat generation in the battery. The conjugated heat transfer is analyzed with the commercial package STAR-CCM+ in terms of inlet flow velocities. The result shows that vortex generator enhances the convective heat transfer by developing thermal boundary layers and secondary flows in downstream, which results in reducing the average temperature of the battery by about 1℃. The heat transfer is enhanced for the whole inlet velocity, while the pressure loss sharply increases at more than inlet velocity of 0.1m/s. The optimum inlet velocity is around 0.1m/s for in terms of the heat transfer and pressure loss.
        4,000원
        12.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Heat transfer and pressure drop of horizontal heat exchangers with different configurations and installations numerically characterized. Three different heat exchangers were used and shaped as linear, wavy, and horizontal slinky, respectively. Installation depth was set from 0.5m to 3.0m and pipe spacing was ranged from 0.3m to 2.1m. The results showed that heat transfer rate and pressure drop were increased with the increase in the installation depth and the pipe spacing. The horizontal slinky heat exchanger carried more heat compared to others due to the greater effective heat transfer surface area per installation area. In terms of a ratio of heat transfer rate to pressure drop indicating the system efficiency, the linear heat exchanger performed better than others. On the other hand, the horizontal slinky heat exchanger was the most effective with respect to a ratio of heat transfer rate to installation cost.
        4,000원
        13.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        교량에서의 화재는 최근까지도 빈번하게 발생되고 있으며, 특히 케이블교량에서 화재가 발생될 시 케이블에 높은 온도상승으로 인해 케이블에 손상 및 파단이 발생될 수 있다. 본 연구에서는 케이블교량에서 발생될 수 있는 화재 시나리오를 설정하였다. 또한 실물차량 화재실험 결과를 토대로 화재강도모델을 제안하여 대상교량 케이블의 열전달 해석을 수행하였다. 해석 결과 단면적이 작은 케이블에서 더 높은 온도상승이 발생되며, 유조차를 제외한 차종의 경우 내화 성능 기준을 초과하지 않는 결과를 나타내었다. 유조차 화재의 경우 갓길에서 발생될 때 최소 단면적 케이블에서 내화 성능 기준을 초과하는 결과 를 보이며, 기준을 초과하는 케이블의 높이는 약 14m로 나타나 이에 따른 대책 및 내화 보강의 필요성을 확인하였다. 본 연구결과를 통해 케이블교량에서 화재가 발생될 때 케이블의 온도변화에 대한 간접적인 평가가 가능한 것을 확인하였으며, 향후 화재 발생 시 바람에 영향을 고려한 열전달 해석과 케이블의 온도상승 시 교량의 사용성에 대한 추가적인 연구가 필요할 것으로 판단된다.
        4,000원
        14.
        2019.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        A-KRS는 한국원자력연구원에서 개발한 파이로프로세싱 처리된 폐기물을 처분하는 개념이다. 고준위 방사성폐기물은 파이로프로세싱에 의하여 최소화되며, 최종 발생된 고준위 방사성폐기물은 모나자이트 세라믹 폐기물 형태로 제조된다. 모나자이트 세라믹 폐기물은 처분공에 영구 처분되어 열을 발생시킨다. 발생된 열은 폐기물을 보호하는 캐니스터 및 완충재의 온도를 상승시켜 설계 기준을 초과 시킬 수 있다. 온도는 처분공 간의 거리로 조절 가능하며 한국원자력연구원에서 해석한 바 있다. 한국원자력연구원에서 해석한 경계조건은 완벽 접촉을 가정한 것이기 때문에, 최초 처분 시에 발생하는 간격에 의해 발생하는 열 저항에 의한 온도 분포는 알 수 없다. 이를 보완하기 위하여, 본 논문에서는 최초 처분 시 존재하는 간격에 의한 열 전달 해석을 수행하였다. 또한 발열체와 캐니스터 간의 공극을 추가하여 온도 분포 해석을 수행하였다. COMSOL 전산해석 소프트웨어를 이용하여 열전달 해석을 수행하였다.
        4,000원
        16.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The effect of inclination angle and attack angle on heat transfer enhancement of trapezoidal vortex generator was numerically investigated. The commercial package STAR-CCM+ was utilized to analyze the heat transfer and flow characteristics with various inclination and attack angle of vortex generator. The result shows that the optimum inclination angles are α =30°~40° in terms of the heat transfer and pressure drop. At more than 40° of inclination angle, the transverse vortex is dominant, so that the pressure drop is severe and the heat transfer is reduced. As the attack angle is increased, the transverse vortex is reduced, so that the pressure drop is improved. The optimum attack angle is β =30° because the heat transfer performance is maintained. However, more than 30° of attack angle, the heat transfer is decreasing.
        4,000원
        17.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Vortex Generators are used in heat exchanger to enhance the heat transfer of air side. 3-D numerical analysis is performed on heat transfer characteristics of a channel with trapezoidal vortex generator. We investigate the effects of vortex generators with two different inclined angles to flow direction which are forward and backward vortex generators. The thermal hydraulic performance such as Nu and pressure drop, is compared quantitatively. The results show that vortex generator enhances the heat transfer by developing boundary layers and secondary flow in the downstream. The downwash flow region corresponds to the maximum Nu, while the upwash flow region corresponds to Nu minimum. In the view of the heat transfer characteristics, FVG is better than BVG. However, when flow is turbulent as Re increases, the pressure drop for FVG is higher than that for BVG.
        4,000원
        18.
        2018.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A numerical approach for ventilated disc brake with holes is carried out to investigate the effect of holes on the heat transfer characteristics. The numerical simulation code STAR-CCM+ is utilized to calculate flow and temperature fields with polyhedral meshes. The steady state results show that the holes make the flow velocity on the outer surface increasing, which induce the improvement of convective heat transfer on the outer surface. In the ventilated channel with holes, the convective heat transfer can be reduced due to the inflow of hot air through holes. In unsteady state, the disc has reached the highest temperature in 1,8s since the brake was engaged. The surface of disc without holes has maximum temperatures along the ventilated channels, while the surface temperatures of dis with holes are uniform.
        4,000원
        19.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the heat flow characteristics of wave heat exchanger was investigated by being applied to the white smoke reduction system. Through numerical analysis, the heat transfer and flow characteristics of the wave heat exchanger with the change of inlet condition of air-side and water-side were analyzed. To investigate the temperature, the absolute humidity, heat transfer rate, pressure drop and turbulence characteristics of the wave heat exchanger, the simulation analysis was conducted by using the commercial computational fluid dynamics software (Solidworks Flow Simulation) under uniform flow conditions. As the inflow rate of air decreased and the inflow temperature of water increased, the heat transfer coefficient of the wave heat exchanger decreased. When the experimental conditions of water-side were the same, the air outlet temperature and absolute humidity of the wave heat exchanger increased with increasing inflow rate of air. To reduce the white smoke, the air outlet temperature and absolute humidity of the wave heat exchanger must be reduced. Therefore, the lower the air velocity and the water inflow temperature into the wave heat exchanger, the more effective it is.
        4,000원
        20.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ablative material in a rocket nozzle is exposed to high temperature combustion gas, thus undergoes complicated thermal/chemical change in terms of chemical destruction of surface and thermal decomposition of inner material. Therefore, method for conjugate analysis of thermal response inside carbon/phenolic material including rocket nozzle flow, surface chemical reaction and thermal decomposition is developed in this research. CFD is used to simulate flow field inside nozzle and conduction in the ablative material. A change in material density and a heat absorption caused by the thermal decomposition is considered in solid energy equation. And algebraic equation under boundary layer assumption is used to deduce reaction rate on the surface and resulting destruction of the surface. In order to test the developed method, small rocket nozzle is solved numerically. Although the ablation of nozzle throat is deduced to be higher than the experiment, shape change and temperature distribution inside material is well predicted. Error in temperature with experimental results in rapid heating region is found to be within 100 K.
        4,000원
        1 2 3