검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 53

        1.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : Carbon dioxide (CO2) is a cheaper and easier to installer fire suppressant than other extinguishing gases and is easy to install, but extinguishes fires by is suffocation. As a result, suffocation accidents continue to occur in facilities equipped with CO2 fire-extinguishing facilities, Emission standards have yet to be established. This study aims to address the issue. METHODS : To effectively remove CO2 emitted from installed systems, we reviewed and analyzed previous related research and existing international standards. RESULTS : In protected areas where CO2 fire-extinguishing systems are installed, emission facilities should discharge the emitted CO2 before it enters the protected spaces. CO2 sensors can determine whether safe entry is possible or whether respirators are required. CONCLUSIONS : This study presented a specific installation method for emission facilities capable of actively discharging CO2. Applying this method is expected to contribute to improving safety in facilities equipped with CO2 fire-extinguishing facilities.
        4,000원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to verify the impact of a metaverse-based safety education program on the fire safety awareness of elementary school students. Utilizing the National Fire Agency's 119 metaverse program, an educational program was implemented for two months, and the experimental group was examined using paired-sample t-tests, while comparisons with the control group were made using independent-sample t-tests. The results revealed statistically significant differences between the experimental and control groups in the area of fire prevention. Although no statistically significant differences were observed over time within each group, the overall average scores for the entire class improved across all areas. Based on these findings, the effectiveness of metaverse-based safety education is suggested; however, a significant difference compared to traditional education was not detected. The study concludes by exploring implications for considerations in the implementation of metaverse safety education in the future.
        4,000원
        4.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study attempted to analyze the comparative advantage in terms of disaster safety costs in verifying the effectiveness and economic feasibility of the high-performance water-bulwark system in the pole tunnel, which was recently promoted as a part of the acceleration of vehicles. The tunnel to be analyzed was divided into a short tunnel(Anyang, Cheonggye) and a long tunnel(Suraksan, Sapaesan). As a result, it was analyzed that 25% of the improvement effect would occur if one lane was secured by applying the Water-Bulwark System. It was analyzed that this is because the time value cost, which accounts for a large proportion of the traffic congestion cost of short tunnels and pole tunnels, differs depending on the congestion time and traffic volume, not the length of the tunnel.
        4,000원
        6.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In school safety education, it was difficult to apply how to link the safety education according to grades year, and student’s interest was reduced due to the repetition of existing safety education contents and the absence of new teaching methods and tools. In this study, as a new type of safety education, a performance forms fire safety education program was developed. This program aims to increase students’ interest and satisfaction in safety education, and to this end, it was connect with korean elementary science curriculum and combined various engineering teaching materials or tools and methods. Developed program was applied to 2,231 students, 25 schools in 10 regions of Gyeonggi-do and surveyed 476 fifth and sixth grade students program satisfaction and 3 factors of interest in fire safety education who could respond to the survey. As a result of applying the program, more than 90% of students responded more than 'satisfied' in all areas. and statistical test(independent t-test and non-parametric test) indicates over-all satisfaction and interest factors in the program are high regardless of gender and grade, so the effectiveness can be guessed indirectly and there is a universal applicability also. Moreover, examining the influence of student interest level in the satisfaction of the fire safety program, it was found that in order to increase the satisfaction of fire safety education, students should have more fun with the content and feel interest in the teacher's teaching method or explanation.
        4,000원
        7.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study attempted to explore how the perception of the necessity of safety education for adolescents affects fire safety consciousness and whether personality factors control the relationship. To this end, a survey was conducted at a high school in region C, and data of 1,049 people who agreed to the survey and responded faithfully were used for analysis. Hayes’ macro was used to analyze the moderating effect, and as a result of the analysis, adolescents’ awareness of the need for safety education increased, and their relationship was significantly regulated by extroversion, openness, and conscientiousness among the five personality factors. A simple regression line analysis was conducted to find out the specific direction, and it was found that the higher the need for safety education in both the group with high extroversion, openness, and conscientiousness, the higher the awareness of safety education. These results suggest that changes in educational methods and contents are needed to raise awareness of the necessity of education in fire safety education and to improve educational motivation, and that it may be helpful to actively utilize students’ personality strengths in education.
        4,000원
        9.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.
        4,000원
        11.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper describes result of a study on safety against a fire of charging cable for mobile phone for vehicle. Combustion on the USB cable in the car was happened while driving. Gas coming from the burning USB cable could be a reason which can make a secondary car accident since the driver also can be embarrassed while driving. In order to prevent a secondary car accident connected on the road, to research a reason why USB cable can emit gas and be burned in charging. We did simulation test with abnormal fault condition for the electronic component on the board in the USB cable. So we get the result from abnormal fault condition simulation test, for instance, shorted test for output terminal of 8 pin switch, shorted test for chip resistor after thermal aging in the condition 25 ℃ , 93 % RH during 48 hours. To analysis the result of all test, Combustion on the USB cable was not the 8 pin but other electrical component such as a chip resistor. Therefore we guess that the reason for USB cable combustion in charging in a car was not 8 pin and a LED but another defective component.
        4,000원
        12.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Currently many geriatric hospitals have been built in Korea because younger people don’t want to care their parents and have been decreasing for labor. However, the increasing geriatric hospitals make the increasing fire safety accidents. Therefore, this study is conducted by survey and face-to-face talk for analyzing fire safety problem of twelve among 15 geriatric hospitals in the north of Chung-Buk area. The result of this study is that infection and fall accident are higher than others and fire safety implement rate of safety rule followed by CEO is 71%. Monthly safety training rate is 49% and initial fire safety training not conducted is 33%. Yearly outside fire safety training rate is 97% but workers who know how to use fire evacuation facility are 61%. Furthermore, safety instruction rate of fire safety manager is much higher than supervisor’s safety instruction. The cause of accident is facility (33%). In conclusion, the institution and rule improvement need for decreasing infection and falling, increasing implement level of fire safety rule and fire safety training, participation rate of supervisor for fire safety, quality of fire safety training, and investment of fire safety facility.
        4,000원
        13.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Because National Fire Safety Codes is mixed performance criteria and specification, and it defines the fire extinguish equipment type and standards that need to be installed in a building as one method. Therefore, to fully reflect the fire risk characteristics of the building, such as the wooden building there is a limit. In this study, suggested to the performance criteria drawn methodologies through fire load of wooden buildings studies, theory on performance and performance analysis to fire extinguish equipment of the wooden buildings is installed according to current fire safety codes.
        4,000원
        14.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Currently many geriatric hospitals have been built in Korea because increasing aging rapidly. However the increasing geriatric hospitals make the increasing safety accidents. Therefore this study is conducted by survey and face-to-face talk with the fire safety managers for analyzing safety problem of geriatric hospitals which number is twelve among 15 geriatric hospitals in the north of Chung-buk area. The result of this study is that geriatric hospitals are very old. Fire safety managers holding the fire safety license are a level 2 issued by the Korea Fire Safety Association(KFSA). And the fire safety inspection ability of them is normal (58%). Furthermore a fire safety budget ratio is 83% (A little) in the company yearly budget. And ratio having the fire inspection equipment in the building is 42% (A little) and 33% (Nothing). Satisfaction ratio of their duty is 66% and they also get stress from heavy duty and heavy responsibility. In conclusion, CEO needs to invest and interest the improvement of job performance, satisfaction ratio and fire safety facility. Also government needs the improvement of system to support and supervise the fire safety of geriatric hospitals consistently.
        4,000원
        15.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The leisure life pattern of people is changing to a familial and enthusiastic way that eventually develops the camping culture. Thus, the number of campers and the size of camping market have been dramatically increased due to significant expansion of camping people. However, many camp grounds and facilities are operating without a proper registration by government rules and regulations. In addition, many of electronic and gas equipment and tools are not used in a safe way and in a safety regulatory boundary. Therefore, campers at the camping ground is situated in a fire and safety hazard. In addition, there is limitation in rules and regulations associated with camping ground safety and fire. This study analyzed the fire and hazard guidelines and rules regulations of developed countries of campground and compared them to the current situation in South Korea. Therefore, this study is to develop a safety and fire hazard guidelines and rules and regulations related to camp ground operation, gas and electronic equipment operation and management. The study will eventually reduce the future fire and safety incidents in a campground in South Korea.
        4,000원
        17.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The live fire test has been playing a critical role in evaluating the goals-to-meet of the weapon systems which utilize the power of explosives. As such, the successful development of the test systems therein is quite important. The test systems development covers that of ranges and facilities including system-level key components such as mission control, instrumentation or observation, safety control, electric power, launch pad, and so on. In addition, proper operational guidelines are needed with well-trained test and operation personnel. The emerging weapon systems to be deployed in future battle field would thus have to be more precise and dynamic, smarter, thereby requiring more elaboration. Furthermore, the safety consideration is becoming more serious due to the ever-increasing power of explosives. In such a situation, development of live fire test systems seems to be challenging. The objective of the paper is on how to incorporate the safety and other requirements in the development. To achieve the goal, an architectural approach is adopted by utilizing both the system components relationship and safety requirement when advanced instrumentation technology needs to be developed and deteriorated components of the range are replaced. As an evaluation method, it is studied how the level of maturity of the test systems development can be assessed particularly with the safety requirement considered. Based on the concepts of both systems engineering and SoS (System-of-Systems) engineering process, an enhanced model for the system readiness level is proposed by incorporating safety. The maturity model proposed would be helpful in assessing the maturity of safety-critical systems development whereas the costing model would provide a guide on how the reasonable test resource allocation plan can be made, which is based on the live fire test scenario of future complex weapon systems such as SoS.
        4,000원
        18.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An effective method for produce munitions effectiveness data is to calculate weapon effectiveness indices in the US military’s Joint Munitions Effectiveness Manuals (JMEM) and take advantage of the damage evaluation model (GFSM) and weapon Effectiveness Evaluation Model (Matrix Evaluator). However, a study about the Range Safety that can be applied in the live firing exercises is very insufficient in the case of ROK military. The Range Safety program is an element of the US Army Safety Program, and is the program responsible for developing policies and guidance to ensure the safe operation of live-fire ranges. The methodology of Weapon Danger Zone (WDZ) program is based on a combination of weapon modeling/simulation data and actual impact data. Also, each WDZ incorporates a probability distribution function which provides the information necessary to perform a quantitative risk assessment to evaluate the relative risk of an identified profile. A study of method to establish for K-Range Safety data is to develop manuals (pamphlet) will be a standard to ensure the effective and safe fire training at the ROK military education and training and environmental conditions. For example, WDZs are generated with the WDZ tool as part of the RMTK (Range Managers Tool Kit) package. The WDZ tool is a Geographic Information System-based application that is available to operational planners and range safety manager of Army and Marine Corps in both desktop and web-based versions. K-Range Safety Program based on US data is reflected in the Korean terrain by operating environments and training doctrine etc, and the range safety data are made. Thus, verification process on modified variables data is required. K-Range Safety rather than being produced by a single program, is an package safety activities and measures through weapon danger zone tool, SRP (The Sustainable Range Program), manuals, doctrine, terrain, climate, military defence M&S, weapon system development/operational test evaluation and analysis to continuously improving range safety zone. Distribution of this K-range safety pamphlet is available to Army users in electronic media only and is intended for the standing army and army reserve. Also publication and distribution to authorized users for marine corps commands are indicated in the table of allowances for publications. Therefore, this study proposes an efficient K-Range Safety Manual producing to calculate the danger zones that can be applied to the ROK military’s live fire training by introducing of US Army weapons danger zone program and Range Safety Manual
        4,600원
        19.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.
        4,200원
        20.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Successful development of weapon systems requires a stringent verification and validation (V&V) process due to the nature of the weapons in which continual increase of operational capability makes the system requirements more complicated to meet. Thus, test and evaluation (T&E) of weapon systems is becoming more difficult. In such a situation, live fire tests appear to be effective and useful methods in not only carrying out V&V of the weapon systems under development, but also increasing the maturity of the end users operability of the system. However, during the process for live fire tests, a variety of accidents or mishaps can happen due to explosion, pyro, separation, and so on. As such, appropriate means to mitigate mishap possibilities should be provided and applied during the live fire tests. To study a way of how to accomplish it is the objective of this paper. To do so, top-level sources of hazard are first identified. A framework for T&E is also described. Then, to enhance the test range safety, it is discussed how test scenarios can be generated. The proposed method is based on the use of the anticipatory failure determination (AFD) and multiple event tree analysis (ETA) in analyzing range safety. It is intended to identify unexpected hazard components even in the environment with constraints. It is therefore expected to reduce accident possibilities as an alternative to the traditional root-cause analysis.
        4,000원
        1 2 3