To promote the diffusion of environmentally friendly equipment, appropriate measures need to be taken for each target group. This study evaluated changes in the influence of mass media on PV installation intentions by generation, based on over 10 years of consumer awareness survey data and the number of newspaper reports.
This study examines new value proposition presented in promoting environment-friendly residential facility. Relationship among changes in social background, consumers’ intention/ value and solar PV systems introduction is evaluated over the last decade since before the Great East Japan Earthquake.
There are several methods of peak-shaving, which reduces grid power demand, electricity bought from electricity utility, through lowering “demand spike” during On-Peak period. An optimization method using linear programming is proposed, which can be used to perform peak-shaving of grid power demand for grid-connected PV+ system. Proposed peak shaving method is based on the forecast data for electricity load and photovoltaic power generation. Results from proposed method are compared with those from On-Off and Real Time methods which do not need forecast data. The results also compared to those from ideal case, an optimization method which use measured data for forecast data, that is, error-free forecast data. To see the effects of forecast error 36 error scenarios are developed, which consider error types of forecast, nMAE (normalizes Mean Absolute Error) for photovoltaic power forecast and MAPE (Mean Absolute Percentage Error) for load demand forecast. And the effects of forecast error are investigated including critical error scenarios which provide worse results compared to those of other scenarios. It is shown that proposed peak shaving method are much better than On-Off and Real Time methods under almost all the scenario of forecast error. And it is also shown that the results from our method are not so bad compared to the ideal case using error-free forecast.
본 연구는 4연동 벤로형 유리온실의 냉·난방 부하를 고려한 PV 시스템의 적정 패널 설치 면적을 도출하기 위하여 BES 기법을 이용하여 온실 및 PV 시스템의 에너지 모델을 설계하였으며 동적 에너지 시뮬레이션을 수행하였다. 대상 작물은 파프리카로 선정하였으며 작물의 적정생육온도를 고려하여 냉·난방장치 및 환기장치의 가동조건을 설정하였다. 2012년부터 2016년까지 총 5년 동안의 기간별 냉·난방부하 및 최대 냉·난방 부하를 환 기팬의 환기량 조건 별로 분석을 실시하였다. 온실의 냉 ·난방 부하 산정과 함께 PV 시스템의 설치 각도에 따른 전력 생산량을 분석하였으며 신재생에너지 공급의무비율을 적용하여 최적 PV 시스템 설계 방안을 도출하였다. 환기팬의 환기량 60AE·hr-1 조건에서 대상 온실의 기간 평균 냉방 부하로 인한 전력 소모량은 174,310kWh, 기간 평균 난방 부하로 인한 전력 소모량은 458,903kWh 로 총 633,213kWh의 전력 소모량이 산정되었다. PV 시스템은 설치 각도를 30o로 설정하는 조건에서 가장 높은 전력 생산량이 나타났으며 월별 최적 각도를 적용하는 조건에서는 고정형 PV 시스템보다 약 5.7% 많은 전력 을 생산하는 것으론 산정 되었다. 최종적으로 대상 온실에 적합한 PV 시스템 패널 면적을 도출한 결과, 고정형 PV 시스템은 521m2의 패널이 필요한 것으로 산정되었고, 가변형 PV 시스템의 경우 494m2의 패널이 필요한 것으로 산정되었다. 본 연구를 통하여 4연동 벤로형 유리온실의 냉·난방 부하를 고려한 PV 시스템의 필요 패널 설치 면적을 도출할 수 있었으며 PV 시스템의 온실 적용 가능성 및 경 제성 평가의 기초 자료로 활용 가능할 것으로 판단된다. 한편, 본 연구에서는 작물 특성 데이터를 확보하지 못하여 작물의 에너지 교환을 고려하지 않았다. 보다 정확한 결과를 도출하기 위해서는 현장 실험 데이터에 기반을 둔 추가 연구가 필요할 것으로 판단된다.
Floating PV generation system, renewable energy power plant, is able to overcome the disadvantages of ground PV generation system and improve generating efficiency. The frame structural system is an established technology among a diversity of structural technologies which has been developed for related fields. In this paper, the both structural safety and characteristics of floating PV generation structures depend on the different placement angle of solar module are investigated to improve the commercial viability, the structural safety, and characteristics of floating PV generation structures. In addition, for the estimation of structural safety, FE analyses are conducted. From the results, the lower placement angle of solar module improves the structural safety of floating PV generation system.
목 적 : 본 연구는 심방세동 치료를 위한 전극 도자 절제술(Radio Frequency Catheter Ablation, RFCA)의 3D mapping 기법과의 최적의 영상 융합을 위해 우심방과 폐정맥을 한 번의 호흡정지로 혈관 조영을 할 수 있는 PV-CMRA(Pulmonary vein-Cardiovascular Magnetic Resonance Angiography) 검사법의 유용성을 알아보고자 하였다.
대상 및 방법 : 2014년 10월부터 12월까지 PV-CMRA를 시행한 심방세동 환자 50명(남성 36명, 여성 14명)을 대상으로 하였다. 3.0T 자기공명영상장치(Achieva Philips Medical System, Netherlands)와 32Channel SENSE torso-cardiac coil을 사용하였고, Test bolus injection 후 우심방에 관심영역을 설정하여 신호강도 곡선에서 조영제 Peak time(sec)을 구한 후, 검사 시작 시간과 Dynamic scan수를 정하였고, 조영제는 자동주입기로 매글루민 가도테레이트(meglumine gadoterate, DotaremⓇ)와 생리식염수 60ml를 각각 3.0ml/sec로 오른팔 주정맥에 주입하여 4D time-resolved MR angiography with keyhole(4D-TRAK)기법을 이용하여 PV-CMRA 영상을 획득하였다. 획득된 영상은 협업 과정을 통해 RFCA 3D mapping 기법의 융합 영상과 비교하였다. 통계학적인 검정은 SPSS 21.0(SPSS Inc, Chicago, IL, USA)을 이용해 조영제 Peak time의 변환 인자를 알아보기 위해 우심방과 폐정맥의 신호강도 값과 환자의 나이, 성별, BMI, 최고, 최저혈압(mmHg), HR(Heart Rate) 측정치와 상관분석(p<0.05)을 하였고, PV-CMRA 영상과 3D mapping 영상의 만족도를 각각 5점 척도로 정성적 분석을 하였다.
결 과 : 우심방 조영제 Peak time은 6.5sec이고, 우심방 신호강도 값과의 Pearson 상관분석 결과는 성별(r=-0.043, p=0.765), 나이(r=0.270, p=0.058), BMI(r=-0.003, p=0.981), 최고혈압(r=-0.122, p=0.400), 최저혈압(r=-0.035, p=0.809), HR(r=0.061, p=0.672)로 나타났고, 폐정맥 신호강도 값과의 Pearson 상관분석 결과는 성별(r=-0.186, p=0.197), 나이(r=0.116, p=0.423), BMI(r=0.082, p=0.569), 최고혈압(r=0.107, p=0.459), 최저혈압(r=0.151, p=0.294), HR(r=0.061, p=0.673)은 유의한(p<0.05) 차이가 없음을 알았다. PV-CMRA 영상과 3D mapping 영상의 정성적 분석결과는 유의한 (p<0.05) 차이를 나타냈다.
결 론 : PV-CMRA 검사는 조영제 Peak time에 영향을 주는 유의한 인자가 없으므로, 한 번의 호흡정지로 조영제 주입속도와 검사시작 시간을 일정하게 유지하여 우심방의 영상을 획득하고 Dynamic scan 수를 조절하여 폐정맥의 영상을 획득할 수 있다. 이 영상을 통계학적으로 유의한 차이를 보인 3D mapping 기법과의 협업을 통해 최적의 영상 융합을 조합하면, 기존 PV-CT와 PV-CMR을 대체 및 보완 할 수 있는 검사법으로써 유용할 것으로 사료된다.
본 연구에서는 평균입경 0.2, 0.5, 1,7㎛ 크기의 α-알루미나 분말을 이용하여 다공성 α-알루미나 지지체의 기공구조를 조절하고자 하였다. 다공성 α-알루미나 지지체는 슬립캐스팅공법을 이용하여 제조한 후 소결하였으며, 이 때 소결 온도가 지지체의 기공특성에 미치는 영향에 대하여 고찰하였다. 제조된 다공성 α-알루미나 지지체는 수은기공분석기를 이용하여 기공크기 및 기공률 등을 분석하였으며, 단일기체투과장치를 이용하여 기체 투과도를 측정하였다. 그 결과 평균입경 0.2, 0.5, 1.7㎛ 크기의 α-알루미나 분말을 이용하여 제조된 지지체는 각각 80, 130, 200㎚의 기공경을 가졌으며, CO2 단일기체에 대해 각각 1300, 1700, 5000GPU를 나타냈다.
종자 등 유전자원의 국가간 교류는 새로운 병원균을 유입시켜 새로운 병을 일으키고 경제적인 손실을 극대화 시킬수 있는 원인을 제공하기 때문에 국가별로 검역이 더욱 강화되고 있는 실정이다. 그러한 연유로 국가별로는 자국에 존재하지 않은 유사한 병원균을 발견할 경우 종자도입을 막고 있어 불필요한 경제적 손실원인이 되기도 한다. 따라서 이러한 손실을 막기위해 각국에 검역소에서는 병원균의 형태적인 감별보다 더 정확한 검정기술이 시급한 실정이다. 본 연구에서는 다중PCR을 통하여 한번의 PCR 증폭으로 벼종자에 존재하는 벼흰잎마름병을 일으키는 Xanthomonas oryzae pv. oryzae (Xoo)과 세균성 줄무늬병을 일으키는 Xanthomonas oryzae pv.oryzicola (Xoc) 를 검출하고 이 두병원균을 판별할수 있는, 국제미작연구소가 최적화한 다중PCR 검정방법의 실질적 적용성 여부를 검증하기 위한 연구였다. 그 결과 51개의 비병원성이나 Xoo 또는 Xoc 와 유사하며 벼종자에서 분리된 균들은 다중PCR검정에서 어떤 밴드도 증폭하지 않은 반면, 대조구(positive control)에서는 알맞은 band size의 amplicon들을 증폭해냈다. 따라서 본 연구에 사용된 국제미작연구소에서 최적화된 다중 PCR방법 (IRRI-optimized multiplex PCR)은 벼종자에서 발견할수 있는 Xoo와 Xoc 의 존재 여부 뿐만 아니라
이들과 형태적으로 유사하나 비병원성균으로부터 구분해 내는데 탁월한 방법이었음을 확인할 수 있었다.
This study describes the result on PV system for evaluating the performance of small fishing boats. Photovoltaic system with 200 watts power generation facilities on the 3-ton fishing boat was carried. Load test was performed on the condition that the work lamps lit during night operations. As a result the performance can be used for more than two hours at 60 watt work lamps. The load test was performed on the condition that fishing vessels are on the cruising condition at sea. The solar power systems have been investigated as a power generation efficiency of about 36.55%. Additional tests show that the power generation efficiency is difficult to expect a maximum of 50% or more.Fuel consumption of fishing boats by installing a solar power system is reduced. Also the PV system is useful for the verification of their availability for fishing vessels as well as the satisfaction of the fishermen. The results for the durability of the photovoltaic device is acceptable, including a solar panel, controller and the performance exhibited no breakage in the harsh marine environment or failure so far. The installed PV system was confirmed that the durability with at least 2 years.
Recently, environmental problems associated with the excessive use of fossil fuel are hot issue throughout the world. As an alternative energy resource, the importance of renewable energy is continuously rising. Especially, growth rate of photovoltaic energy generation is one of the best. In this paper, floating PV generation system made of pultruded fiber reinforced polymeric plastic (PFRP) is discussed. It is well known that PFRP has many advantages such as high corrosion resistance, high specific strength/stiffness, etc. Compared with conventional construction materials. To investigate the structural behavior under flow induced dynamic loading, members and connections of members are tested under cyclic loading. It was found that the structural system is strong enough to resist such a cyclic loading.
The floating PV generation structure installed on the surface of water has been recently issued as a representative items for the low carbon and green growth campaign. Moreover, the studies and developments for the structure and construction improvements of floating PV generation structure have been in progress. For example, in the previous research, the floating PV generation structure consisted of pultruded FRP and SMC FRP members is suggested. In this study, we conduct the analytical and experimental studies for estimating the structural characteristics of SMC FRP vertical members. From the analytical and experimental results, it is found that SMC FRP vertical members used for floating PV generation structure have sufficient structural safety and stability.
Pultruded glass fiber reinforced polymeric plastic (PFRP) and FRP member manufactured by sheet molding compound (SMC) have superior mechanical and physical properties compared with those of conventional structural materials. Since FRP has an excellent corrosion-resistance and high specific strength and stiffness, the FRP material may be highly appreciated for the development of floating-type photovoltaic (PV) power generation system. In this paper, advanced floating PV generation system made of PFRP and SMC is designed. In the design, it includes tracking solar altitude by tilting photovoltaic arrays and tracking solar azimuth by spinning structures. Moreover, the results of the finite element analysis (FEA) are presented to confirm stability of entire structure under the external loads. Additionally, installation procedure and mooring systems in the Hap-Cheon Dam are discussed and the measurement of strain under the actual circumstances is conducted for assuring stability of actually installed structures. Finally, by comparison with allowable stress, appropriate safety of structure is confirmed to operate the system.
As the balcony expansion of residential building was legalized, the expansion generation is tend to increased continuously of existing residential building or condominium complex. But balcony is the service area. So, it is worried about defect occurrence of extension construction because thermal insulation effect is insufficient to balcony installed an aluminum sash. Therefore, it is desired the method to minimize the damage of performance improvement of the windows which has an influence directly on the performance defect. See-through a-si is effective to reduce the cooling loads and sunlight, to produce the electricity by installing a-si at the wall and windows of residential building. This paper has predicted producing electricity and have analyzed heating/cooling load based on balcony expansion and building-integrated PV installation in residential building.
Real Time PCR을 이용한 벼 흰잎마름병균의 밀도를 측정할 수 있는 새로운 방법을 개발하였다. Real Time PCR을 이용하여 벼 흰잎마름병을 예찰하기 위하여 TaqMan MGB probe를 이용한 프라이머인 Xan_PahgeF & Xan_PahgeR primer와 Xan_Pahge FAM MGB probe를 제작하였으며, 높은 특이성이 인정되었다. 병원균 배양액, 벼 흰잎마름병원균의 DNA, 병원세균에 오염된 물에서도 효과적으로 검출이 되었다. 농수로물이나 관개수에서 벼 흰잎마름병균의 밀도를 측정할 때 정량 PCR의 저해인자 제거 후 신속하게 벼 흰잎마름병균의 밀도를 측정할 수 있다.
This paper presents a development process of a forecast and monitoring system for a photovoltaic (PV) solar plant. PV solar system is one of sustainable resource of energy. So, Korean government encourages businessmen to build a PV solar plant. Renewable Portfolio Standard (RPS) system is one of encouraging policies. Most RPS businessmen use monitoring system for a PV solar plant and they need an accurate forecast of power generation for business purpose. Therefore we propose an estimating algorithm of power for a PV solar plant using weather forecast. Proposed algorithm is implemented in a forecast and monitoring system and it works better than existing estimating methods.
In this study, we conduct the economical analysis about the floating tracking PV generation structure manufactured by steel, aluminum, and GFRP (glass fiber reinforced polymeric plastic) structural member. The structural safety of floating PV generation structure has been proved through numerous previous researches. Moreover, the generating efficiency of tracking PV generation system can be more larger than immobile system. In this study, structural analysis using the FEM method has been performed to establish the safety of the floating tracking PV generation structure and commercial viability evaluation has been performed through the cost of materials.
The EnergyPlus is used for the analysis of energy demand at two rural house models. Photovoltaic (PV) system is installed to reduce the energy demand of annual building. The energy economic analysis is performed to provide quantitative data at choosing a suitable house model. Two types of PV system installations are considered as each building type. Among 4 different cases analyzed through this study, the best setup is provided for 12.3 years at recovering PV system installation cost.
벼 흰잎마름병균의 정확한 진단을 위하여 PCR용 진단 kit를 개발하였다. 본 PCR kit를 개발하기 위하여 벼 흰잎마름 병균 유전체 정보 중 phage-related integrase and transposase gene의 염기서열을 이용하여 프라이머를 각각 제작하였다. 프라이머 염기서열은 XOP-F (5-CGG TCT GCT CAA TGA GGA AGA-3)와 XOP-R2 (5-TGC AAT TGG TGT TCTCCA GG-3), XOT-F (5-GTC ATA GGT GAG GCT TCCC-3)와 XOT-R2 (5-AGT GCG ATC TTT CAG CAG G-3)로 벼 흰잎마름병균의 DNA를 401bp와 492bp를 증폭하게 제작하였다. PCR 증폭은 벼 흰잎마름병균만 증폭하였으며 다른 세균인 Escherichia coli, Agrobacterim, Pectobacterium caratovora subsp. cartovorum, P. atrosepticum, Pseudomonasputida, P. syringae, P. savastanoi pv. phaeolicola, P. savastanoipv. savastanoi and P. marginalis pv. Marginalis 등은증폭되지 않아 특이성이 인정 되었다. 본 프라이머로 병이 의심되는 벼잎과 논물에서 병원균을 3시간 이내에 검출할 수 있었다.