검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 107

        41.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For the hydrogen economy system being tried starting with the 21st century, the fields that was not dealt with so far, such as the safety measure for large leakage accidents, the safety problem at infrastructures like a hydrogen station, the safety problem in terms of automobiles depending on introduction of hydrogen cars, the safety problem in a supply for homes like fuel cells, etc., are being deeply reviewed. In order to establish a safety control system, an essential prerequisite in using and commercializing hydrogen gas as an efficient energy source, it is necessary to conduct an analysis, such as analysis of hydrogen accident examples, clarification of physical mechanisms, qualitative and quantitative evaluation of safety, development of accident interception technologies, etc. This study prepared scenarios of hydrogen gas leakage that can happen at hydrogen stations, and predicted damage when hydrogen leaks by using PHAST for this.
        4,000원
        42.
        2013.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        복막 가성점액종은 원발병소에 관계없이 복막표면과 대망 등에 점액성 물질이 침착되면서 점액성 복수가 복강 내에 축적되는 상태를 말하는 임상적 질환이다. 원인질환으로 매우 드물지만 췌관내 유두상 점액종양이 보고되고 있으며, 시술과 관련된 점액의 누출, IPMN 파열 및 샛길 형성에 의한 복강내 점액누출 등이 유발기전으로 제시되고있다. 저자들은 췌장의 악성 IPMN 점액누출에 의해 발생한 복막 가성점액종 1예를 경험하였기에 문헌고찰과 함께 보고하는 바이다.
        4,000원
        43.
        2012.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 다채널 자속누설 센서를 이용하여 강케이블의 국부손상을 검색하였다. 먼저 자속누설 기법을 고정된 케 이블 구조물에 적용하기 위해 프로토타입의 8채널 자속누설 센서헤드를 제작하였고, 국부손상이 발생한 케이블을 구현하 기 위하여 PVC 파이프에 강케이블을 채워 강케이블 다발 시편을 제작하였고, 케이블 시편 외부 및 내부에 다양한 크기 및 방향을 가지는 국부손상을 단계적으로 발생시켰다. 이와 같이 제작된 강케이블 시편을 대상으로 각 손상단계에서 자속누설 센서헤드를 이용하여 자속신호를 스캔하고 출력전압으로 표현하였다. 이어서 일반극치분포를 이용해 손상유무를 판단할 수 있는 기준이 되어줄 임계값을 설정하였고, 이를 각 채널에서 계측된 자속신호와 비교하여 객관적인 손상판단을 수행하 였다. 또한 케이블 모니터링에 있어 가장 중요한 정보인 손상의 길이방향 위치를 효과적으로 검색하기 위해 모든 채널의 자속값을 합하여 총합값의 형태로 임계값과 함께 나타내었다. 최종적으로 임계값을 초과한 부분의 길이방향 및 원주방향 위치를 실제 손상과 비교함으로써 본 기법의 국부손상 검색 가능성을 살펴보았다.
        4,000원
        44.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        해양구조물 수중부의 해양생물 부착을 방지하는 효과적인 방법으로 방오도료를 사용하고 있다. 트리부틸틴(Tributyltin, TBT) 화합물은 우수한 방오성능을 가져 지금까지 광범위하게 사용해 되어 왔으나, 유해물질 사용금지에 따라 새로운 기술을 적용한 방오도료 개발이 진행되고 있다. 신규 방오도료는 낮은 독성을 가지면서도 우수한 방오성능을 가져야 한다. 본 논문에서는 상용 TBT-free 방오도료 3종(아산화동 함유 자기마모형 도료(Cu SPC AF), 아산화동을 함유하지 않는 자기마모형 도료(Cu-Free SPC AF), Foul-release 실리콘 도료(Foul release AF)의 용출수가 가지는 환경영향성을 조피볼락과 알테미아를 사용하여 평가하였다. 용출수에 대한 급성독성을 조사한 결과 방오도료 용출수의 농도와 생물종의 생존율은 반비례하는 경향을 나타내었으며, 자가마모형 도료가 Foul-release 실리콘 도료보다 상대적으로 높은 급성독성을 가지는 것을 확인할 수 있었다.
        4,000원
        45.
        2010.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        흙댐에서의 누수 구역을 판별하기 위해 다채널 연속 온도 모니터링을 수행하고 이를 검증하기 위해 전기비저항 물리탐사를 함께 수행하였다. 일반적으로 댐이나 사면과 같은 인공구조물의 내부는 시간과 위치에 따라 상이한 온도 분포를 갖는 것으로 여겨진다. 이와 같은 분포는 구조물의 안전성을 판단하는 데 매우 중요한 기본 자료로 이용될 수 있으며, 특히 댐 구조물의 경우 과도 침투수나 누수에 의한 위험 대역을 파악할 수 있는 기술로 이용될 수 있다. 그러나 기존의 온도 측정 방식은 대형 구조물의 온도를 연속적으로 동시에 측정할 수 없는 단점을 가지고 있다. 본 연구에서는 이를 극복한 새로운 온도 모니터링 장비를 이용하여 댐의 상부 및 하부에 걸쳐, 여러 지점에서 동시에 온도 분포를 측정하였으며, 실내 시험을 통해 누수 대역이 온도 분포의 이상을 충분히 반영하고 있음을 관측하였다. 또한 대상 댐의 전 구역에 걸쳐 전기비저항 조사를 수행한 결과와 온도 모니터링 자료를 비교 분석하여 누수구역의 판별력을 높일 수 있는 방법을 제시하고자 하였다.
        4,000원
        47.
        2001.02 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        상부전극, Pt, Ir, 그리고 IrO2, 에 따라 수소 열처리전과 후, 그리고 회복열처리시 누설전류특성을 고찰하였다. Pt/PLZT/Pt 케페시터는 수소열처리 후에 다시 회복열처리를 수행하면 완전히 이력곡선의 회복을 보이며 또한 피로특성도 거의 회복 된다. Pt과 IrO2 상부전극의 경우의 진 누설전류 특성은 열처리조건에 관계없이 강한 시간 의존성을 갖는 space-charge influenced injection모델에 적합하다. 반면에 Ir 상부전극의 경우는 Ir과 PLZT 사이의 계면에 헝성된 전도성 상인 IrO2로 인해 높은 누설전류 밀도를 보이면서 relaxation current 영역이 없이 steady state 영역을 보이는, 주로 Schottky barrier 모델에 의해 설명된다.
        3,000원
        48.
        2000.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        인공폐는 실제 폐의 기능을 대행하는 장치이며, 주요 기능은 정맥혈에서 이산화탄소를 제거하고 산소를 첨가하여 동맥혈화하여 개심수술시 신체의 모든 조직에 충분한 양의 동맥혈을 공급한다. 또한 체외순환 생명보조장치(ECLS 또는 ECMO)는 심한 호흡부전증에 일반적으로 이용되지만 미래의 폐 이식에 사용될 것이다. 현재 미세다고엉 폴리프로필렌 중공사를 사용하고 있는 막형 인공 폐는 두 가지 문제가 있다. 환자의 체계적인 항응고가 필요하며, 오랜 기간의 사용은 막을 통하여 혈액 쪽에서 가스 쪽으로 혈청 누출을 일으킨다. 본 연구는 미세다공성 폴리프로필렌(PP)막에 폴리디메틸실록산(PDMS)을 적충한 PP/PDMS막을 제조하고, 폴리프로필렌 막에서 유발하는 혈청 누출을 최소화하는 기술에 대하여 연구하였다. Lee-White법에 의한 whole blood의 혈전형성 실험 후 사용된 막의 기체 투과도는 PP막에서는 크게 저하되었지만, PP/PDMS막에서는 거의 동일하게 유지되었다. 그러므로 PP막에서 유발되는 혈청 누출을 PP/PDMS막에서는 해결할 수 있었다. 또한, PP/PDMS막에서는 이산화탄소의 기체토과율이 산소보다 11.5배였다.
        4,000원
        49.
        1995.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        열산화 및 PECVD법으로 p-type(100)Si wafer위에 Ta2O5, 박막을 형성한 후 이들 박막의 전기적 특성과 박막응력 상호간의 관계를 연구하였다 열산화 시편의 경우 dc magnetron sputtering법으로 Ta을 증착시킨 후에 산화온도와 시간을 변수로 열산화시켜 박막을 형성시켰으며 PECVD 시편의 경우 RF power density를 변화시켜가면서 박막을 형성시켰다. 이들 박막의 전기적 특성과 박막응력을 조사하여 전기적 특성과 박막응력 상호간의 관계를 조사한 결과 열산화 박막의 경우 누설전류와 박막응력은 독립적인데 반해 PECVD 박막의 경우 박막응력의 절대값은 누설전류가 증가함에 따라 증가하였다.
        4,000원
        50.
        1994.08 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 반응기체 PaCl5 (99.99%)와 N2O(99.99%)를 사용하여 PECVD법으로 P-type(100) Si기판위에 Ta2O5 박막을 증착시킨후 RTA 후처리를 통하여 누설전류를 개선시키고자 하였다. 실험결과, 증착온도 증가에 따라 굴절율은 일정하게 증가하였고 500˚C에서 최대 증착속도를 보였다. 증착된 Ta2O5막의 FT-IR 분석결과 증착온도 증가에 따라 Ta-O bond peak intensity가 증가함을 알 수 있었으며, 누설전류 특정결과 증착온도가 증가함에 따라 누설전류값이 감소함을 알 수 있었다. 또한 증착된 Ta2O5막을 RFA방법을 이용하여 후처리 한 결과, as deposited 상태보다 누설전류가 감소함을 알 수 있었으며 이는 RTA처리후 AES와 FT-IR 분석을 통하여 Ta2O5막 내의 oxygen농도와 Ta-O bond peak intensity를 측정한 결과 RTA 후처리에 의하여 Ta2O5막내의 존재하는 O-deficient 구조들이 감소한 때문이었다.
        4,000원
        51.
        2020.02 KCI 등재 서비스 종료(열람 제한)
        Purpose: The purpose of this study is that victims of technology leaks and people concerned about leaks complain of stress over security concerns. However, there are no psychological treatments among the government's comprehensive plans to prevent technology leaks. Therefore, the government intends to present education methods using the NLP (Neuro Linguistic Program), a collective counseling technique, to heal the psychological injury of the victims. Psychological counseling methods include cognitive behavioral therapy, psychoanalytic behavioral therapy, humanism therapy, art therapy, and other psychological therapies. Among them, NLP (Neuro Linguistic Programming) method was used. NLP has three concepts: neuron, language, and programming, and is used as a general method for group counseling. Research design, data and methodology: In relation to composition, Chapter 1 explained the purpose and necessity of the study, Chapter 2 explained the types of psychological counseling and NLPs to help understand the study, introduced the prior study related to the development of collective counseling programs through NLP, and Chapter 3 developed a security psychological counseling education program. In addition, FGI(Focus Group Interview) was conducted for professionals. Results: Corporate counseling considered most in this study should satisfy client, counselor and manager differently from individual counseling. For this purpose, the result was composed of 11 times. In order to derive personal problems for clients, they consisted of finding, loving, expressing, and emancipating self. And, It solved the leakage anxiety to suggest a professional solution for the counselor. In addition, this course helps them become familiar with counseling techniques for becoming a good security administrator. Lastly, it was configured to leave the result for the manager to suggest the organizational development method through this training. The implication of this study is to derive psychological counseling methods for security officers. Most companies in the field of security counseling complain about technology leakage stress. There is currently no psychotherapy support project under the policy. And It was developed because it can expect sales improvement from security consultation. Conclusions: In conclusion, the results were organized to be left to the manager so that he could suggest how to develop the organization through this time.
        52.
        2019.10 서비스 종료(열람 제한)
        현재 K-water는 부단수 관내부 탐사장비를 도입하여 누수탐사 및 관상태 조사 그리고 위치탐사를 수행하고 있다. 누수 탐사는 누수지점을 정확히 확인할 수 있는 탐사기법으로 신속한 사고를 복구 가능케 함으로써 복구비용 절감 및 피해 확산을 방지하고 있다. 또한, 도로구간 등 굴착확인이 곤란한 지점과 GIS 불탐구간 등 어려운 여건에서도 누수 여부 확인 등 정밀한 진단이 가능하게 되었다. 그리고 관상태 조사로 노후관 상태 조사를 실시함으로써 구간별 적정 개량공법 및 사업비를 선정하여 합리적 의사 결정을 지원하고 있다. 또한 위치가 불명확한 관로의 위치탐사를 실시하여 사고 발생 시 대규모 단수피해를 사전에 방지하고 안정적인 시설물 유지관리에 기여하고 있다.
        53.
        2019.10 서비스 종료(열람 제한)
        강구조물에서는 노후화, 과대하중, 반복하중 등 다양한 요인으로 인해 손상이 발생하게 될 수 있는데, 이러한 손상의 초기대응이 늦을 경우 대형사고로 이어질 가능성이 있다. 이러한 이유로 손상을 조기에 탐지하기 위하여 여러 비파괴검사가 진행되고 있는데, 현 검사 기법으로는 대형 강구조물에 적용하기 어려운 단점이 있다. 따라서 본 연구에서는 연속체 형태의 구조물 진단에 주로 사용되는 누설자속 기반 비파괴검사 기법을 적용하였다. 누설자속 기반 비파괴검사 기법의 가능성을 확인하기 위해, 강판 시편에 각각 다른 깊이의 인위적인 손상을 가하였다. 이후 제작한 센서헤드를 시편에 접근시켜 누설자속의 크기를 측정하였다. 이로부터 추출된 신호에 신호처리를 하여 강판의 손상을 검출하였다.
        54.
        2019.04 서비스 종료(열람 제한)
        Safety, Durability, and Usability of the Concrete Structure affecting among, there are crack and leakage the main damage is crack and leakage. Especially, Leakage is accompanied by Efflorescence, and provoke steel corrosion, exfoliation. This leakage is leaked to the exterior of the concrete surface in the shape of line or face, the method of repair varies with the shape of leakage. Accordingly, this paper will introduce case analysis of the shape of the water leakage to water leakage site in the lining structure of the NATM tunnel for utilize investigation method and basic data for the method of repair.(leakage, Efflorescence)
        55.
        2018.10 서비스 종료(열람 제한)
        Measurement items of phenomena reflecting the overall condition of the structure during the measurement for safety management in the dam include water volume and displacement depending on the number of water leaks. Leakage measurements, which are important indicators to be measured on a dam, require significant accuracy and reliability. However, the dam design basis includes general measurement equipment, but the lower the limit for calculating the water leakage, and the lack of accuracy and reliability is a phenomenon. Therefore, in order to improve accuracy and reliability of the dam's major measurement items, the standards of the dam water measuring meter and the suitability of the water leak calculation formula (based on USBR) are reviewed to elicit problems and suggest solutions.
        56.
        2018.10 서비스 종료(열람 제한)
        In this study various investigations were carried out to analyze the causes of leakage for 20 years on the slope of the downstream side of the dam during the ○○ dam precision safety diagnosis. Analysis showed that the possibility of underground water flowing through the valley section of the mountain area extremely low, and that direct leakage of the reservoir's freshwater was confirmed as the main leakage path.
        57.
        2018.10 서비스 종료(열람 제한)
        In this study, a magnetic flux leakage (MFL) method that is known as a suitable non-destructive evaluation (NDE) method for continuum ferromagnetic members was applied to detect the various types of local damages of the steel wire ropes. 3types of artificial damages, such as cutting, corrosion and compression, were formed on wire rope specimen. A multi-channel MFL sensor head that can maintain the constant lift-off was fabricated to scan the wire rope specimen. The fabricated MFL sensor head measured the magnetic flux signals from the three types of damaged specimens. The capability of damage detection according to damage type was verified from the measured MFL signals from each type of damage. And, the characteristics of the MFL signals were compared and analyzed by type of damage.
        58.
        2018.06 KCI 등재 서비스 종료(열람 제한)
        방사선 치료 시 환자는 부득이하게 산란선과 누설선에 의한 2차 방사선 피폭을 받게 된다. 진단용 방사선의 경우 진단참조준위로 환자의 피폭을 줄이기 위한 가이드라인을 제시하고 있지만 치료용 방사선의 경우 2차 방사선에 의한 피폭선량이 상당함에도 불구하고 상한치 설정 시 치료 효과의 저감을 이유로 선량을 제한하지 않고 있다. 이에 본 연구는 선형가속기를 이용한 방사선 치료 시 원거리 조직에서 환자가 받을 수 있는 2차 방사선을 형광유리선량계로 측정하였으며 형광유리선량계의 빌드업 특성에 따른 형광량의 포화도를 측정하였다. 연구 결과 조사야 경계로부터 거리가 멀어질수록 피폭선량은 급격히 줄어들었으며, 두부 1 Gy 조사 시 경부 18.45 mGy, 경부 1 Gy 조사 시 두부 15.55 mGy, 흉부 1 Gy 조사 시 경부 14.26 mGy, 골반 1 Gy 조사 시 흉부 1.14 mGy로 피폭되었다. 형광량의 포화도는 판독시점에 따라 1.8 ~ 4.8% 정도 과대평가 될 수 있음을 확인하였다.
        59.
        2018.06 KCI 등재 서비스 종료(열람 제한)
        유리 표면에 방사성동위원소 14C를 고착시키고 문지름 시험을 통해 시험용지별 전이 인자와 표면 형상을 관찰하여 방사성동위원소 누설 점검을 위한 건식 및 습식 문지름 시험법을 연구하였다. 건식 문지름 시험법은 티슈 용지가 종이 필터를 대체 가능할 정도로 2배 높은 전이 인자를 보였고, 습식 문지름 시험법은 종이 필터 용지가 티슈 용지에 비하여 3배 높은 전이 인자를 보였다. 일반적으로 누설 점검을 위해 종이 필터를 사용하고 있지만 건식 문지름 시험법에서 티슈 용지가 대안이 될 수 있음을 보였다.
        60.
        2018.04 서비스 종료(열람 제한)
        Concrete residential structures are being redesigned for maximum space utilization efficiency by including parking lots and other convenience facilities. However, there are increasing problems of leakage due to various environmental and deterioration conditions. This paper proposes the a world-wide-web based professional information sharing system designed to provide solutions, alternatives and technical information for leakage prevention and effective design at the beginning of the construction stage.
        1 2 3 4 5