        1.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Failure to comply with the performance test requirements for the centrifugal pumps at power plants often results in performance dissatisfaction as a result of field tests. This study proposed a method of reducing the uncertainty of the field test results by evaluating the systematic error in the measurement system caused by failure to follow the test requirements using the computational fluid dynamics(CFD) technique. As a result of the evaluation of the systematic error and reflecting it in the performance test data, it was confirmed that the error occurred at a constant rate with respect to the flowrate and that the pump, which showed a difference in performance actually had the same performance.
        4,000원
        2.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The change in pressure measurement according to the low pressure tap blockage rate of the Venturi flowmeter used in domestic nuclear power plants was approached numerically. Blockage rates were modeled dividing by 1/10dT to the downstream side of the low pressure tab to identify differential pressure changes. As a result, differential pressure increased in proportion to the blockage rate, and there was no change in differential pressure measurement at 10 to 40 percent with relatively small blockage rate, but the error rate of 50% to 0.3% or higher was shown.
        4,000원
        3.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to measure the flow rate of liquid sodium, the flow measurement method should be determined by considering the opacity of sodium, the chemical reaction with air and water, and so on. By using the segmental wedge flowmeter which is one of the representative devices for flow measurement, the methodology for measuring the liquid sodium flow was examined and the flow characteristics were observed. The variations of the discharge coefficients according to various flow conditions were also evaluated. In addition, the structural integrity at high temperature condition was evaluated by using the liquid sodium as a working fluid and these study results were reflected in the design of the segmental wedge flowmeter.
        4,000원
        4.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 홍수기 유량측정의 어려움을 극복하고자 물 과 비접촉식으로 유속을 측정하여 유량을 산정하는 전 자파표면유속계(microwave water surface current meter, MWSCM)의 성능개선 제품인 범용 MWSCM에 대하여 소개하고자 하였다. 기존에 사용 중인 MWSCM은 홍수 용으로써 연중 활용도가 낮아 이것의 이용성을 높이고 자 성능을 개선하였다. 유속측정 범위를 확장하여 평∙ 갈수기에도 하천 유량측정이 가능하게 하였다. 즉 기존 홍수용 MWSCM의 유속측정 범위가 0.5~10.0 m s-1이 었던 반면, 금번에 개발된 범용 MWSCM은 0.03~20.0 m s-1로 홍수기 및 평수기 측정이 가능하도록 성능을 개선하였다. 이를 위해서 사용주파수의 변경(10 GHz → 24 GHz), 안테나 및 송수신부 회로가 새롭게 설계 제작 되었다. 이와 더불어 기존 홍수용 MWSCM 사용자들의 개선요구사항-기기 경량화, 유속 안정화, 자체점검기능, 저전력, 방수 및 방습-을 파악하여 반영함으로써 현장에 서 유량을 측정하기에 용이한 기기로 개발하였다.
        4,000원
        5.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 단면변화를 고려한 수위-단면적 변화 및 평 균 유속-단면적 간의 상관관계를 분석하여 유량 산정 및 하천관리에 활용하고자 하였다. 수위에 따른 단면적 변화 는 SB-A 지점은 1.0 m, 1.9 m, SB-C 지점은 0.6 m, 1.8 m, CL-A 지점은 1.0 m, 1.8 m, OS-A 지점은 0.6 m, 2.0m에서 발생되었다. 이 중 첫 번째 변화는 평∙저수기에 해당되 고, 두 번째 변화는 홍수기 및 하천 좌∙우 안에 인위적 ∙자연적으로 형성된 둔치 등으로 판단된다. 수위-단면적 변화에 따른 관계식의 기울기는 지수형 0.5539~1.9013, 선형 9.040~52.544의 범위를 가진다. 기울기는 두 곡선 모두 고수위로 갈수록 증가하는 경향을 보인다. 평균유 속-단면적 변화의 관계는 지수와 직선의 방정식으로 지 수형 기울기와 상관계수는 각각 0.1182~0.8734, 0.22~ 0.86이며, 선형의 기울기와 상관계수는 0.0028~0.1032, 0.20~0.87로 분석되었다. SB-A, SB-C 지점의 저수위는 다른 수위보다 상관관계가 높게 산정되었는데, 이는 수위 구간이 좁고, 하천 단면적의 변화가 크지 않기 때문으로 판단된다. CL-A, OS-A 지점은 월류보의 영향으로 저수위 일 경우에 상관관계가 낮았다. 수위-단면적, 평균유속-단 면적의 상관관계 및 곡선식 등을 이용하여 하천 정비계 획 등의 수립에 활용할 수 있으며, 제외지의 단면적이 변 하는 지점의 유량 변화 등의 예측에 활용할 수 있을 것 이다.
        4,000원
        6.
        2009.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It is important to find the effective position for cough and sputum clearance in respiratory physical therapy. The purpose of this study was to compare the changes in peak expiratory flow (PEF), forced expiratory volume in 1 second (FEV1), and peak cough flow (PCF) related to functional level and measurement position in patients with Duchenne muscular dystrophy. Twenty one subjects were classified into three functional levels, and measurements was undertaken in three different measurement positions (upright sitting, 45˚ reclining and supine). Vitalograph PEF/FEV DIARY was used to measure PEF and FEV1, and Ferraris Pocket Peak was used to measure PCF. Mixed two-way analysis of variance and Bonferroni post-hoc test were used for statistical analysis. The results of the study were as follows: 1) Significant main effects for measurement position were found. 2) PEF was the highest in upright sitting, followed by 45˚ reclining, and supine in order. 3)FEV1 in upright sitting and 45˚ reclining were significantly greater compared with that in supine. 4) PCF in upright sitting and 45˚ reclining were significantly greater compared with that in supine. 5) No significant main effects for functional level were found in PEF, FEV1, and PCF. 6) No significant functional level by measurement position interactions were found in PEF, FEV1, and PCF. Therefore, it is concluded that upright sitting and 45˚ degree reclining positions are recommended for effective cough and sputum clearance.
        4,000원
        7.
        2017.08 KCI 등재 서비스 종료(열람 제한)
        음향 도플러 유속계(Acoustic Doppler Current Profiler, ADCPs)는 하천의 유량측정에 널리 사용되고 있으나, 유량 측정성과의 불확도를 평가하는 방 법에 대하여 진행된 연구는 부족한 현실이며, 이는 실제 하천에서 유속 및 유량 등의 수리량을 조절하는 것이 현실적으로 불가능하여 ADCP의 불확도 요인 별 실험 및 분석이 어렵기 때문이다. 유량 및 수리량의 측정 불확도를 평가하기 위하여 과학 및 공학 분야에서는 다양한 연구들이 진행되어 왔으며, 그 중 국 제적으로 공인받고 있는 방법 중 하나가 GUM (Guide to the Expression of Uncertainty Measurement)이다. 본 연구에서는 GUM 표준안을 기반으로 ADCP의 유량 측정 불확도를 평가하기 위한 연구를 수행하였다. ADCP의 유량 측정 불확도 요인별 분석을 수행하기 위하여 유량 공급의 조절이 가능한 실 규모 수로를 보유하고 있는 하천실험센터에서 실험을 진행하였으며, ADCP의 측정 정확도에 영향을 미치는 수심, 측정 지점에서 하안까지의 거리, ADCP 의 잠김 깊이, 유속 오차, 측정 시간, 반복 횟수, 하상 조건 등에 대한 측정 정확도 평가 실험을 수행하였다. ADCP로 유량을 측정하는 방법은 지점측정방식 을 기반으로 유속-면적법을 통해 산정하는 방법과 일반적으로 사용되는 이동측정방식이 있으며, 본 연구에서는 ADCP의 지점측정방식을 통해 유량을 산정 하는 Section-by-Section 방법으로 산정된 유량의 불확도를 평가하였다. 모든 측정 결과는 요인별 불확도 평가를 수행하기 위하여 유속은 ADV, 수심은 광 파기로 측정된 결과와 비교하였다.
        8.
        2015.08 KCI 등재 서비스 종료(열람 제한)
        홍수기유량측정의어려움을극복하고자물과비접촉식으로유속을측정하여유량을산정하는전자파표면유속계를개발하여실무에적용하고 있다. 기존에 사용 중인 전자파표면유속계는 홍수용으로 연중 활용도가 낮아 이의 활용도를 높이고자 전자파표면유속계의 성능개선을 통하여 유속측정범위를확장하여평․갈수기에도하천유량측정이적용할수있게하였다. 즉기존홍수용전자파표면유속계의유속측정범위가0.5∼10.0 m/s이었던 반면, 금번 개발된 고성능 범용 전자파표면유속계는 0.03∼20.0m/s로 홍수기뿐만 아니라 평수기에 유속측정이 가능하도록 성능을 개선하였다. 전자파표면유속계를 이용한 저유속의 측정을 위해서 필요한 요소를 조사한 결과, 송신신호의 수신단 유입을 차단하여 저유속의 미세한수신신호에대한검출능력을향상할수있도록송수신격리도의개선, 이와함께공진기의위상잡음특성개선이저유속의검출에필수사항 임을파악하였다. 따라서이를감안하여안테나의송신부와수신부가분리된안테나를개발함으로써송수신격리도를개선하였고, 기존공진기의 위상잡음특성을개선하기위하여위상고정주파수합성기를공진기로적용함으로써저유속검출성능을개선하였다. 또한고성능범용전자파표면 유속계의 사용편의성 증진을 위하여 안테나의 소형, 경량화 제작을 가능토록 하고자 사용주파수(10 GHz→24GHz)를 변경하였다. 이와 더불어 기존전자파표면유속계사용자들의개선요구사항-측정유속안정화, 자체점검기능, 저전력, 방수방습-을반영함으로써현장에서유량측정하기에 간편한 기기로 개발하였다.
        9.
        2015.07 KCI 등재 서비스 종료(열람 제한)
        ADCP는 하천의 3차원 유속과 수심 자료를 매우 효율적이고 빠르게 측정할 수 있으며, 그 자료의 공간 및 시간적 해상도는 기존의 전통적인 유속 측정 방법들과 비교하여 매우 정밀하다는 장점이 있다. 하지만 ADCP는 하상 부근과 센서 근처에서의 미계측 영역이 발생하고 이 미계측 영역의 유속을 얼마나 정확하게 산정하느냐에 따라 ADCP 유량 측정의 정확도에 영향을 미친다. 본 연구에서는 ADCP 유량 산정 시 범용적으로 활용되고 있는 1/6 멱법칙(power law)을 활용한 미계측 영역의 유량 측정 결과의 정확도를 분석하였다. 이를 위해 실규모 직선수로에서 ADCP를 고정시킨 상태에서 측정한 유속 자료를 1/6 멱법칙과 대수 법칙(log law)을 적용하여 외삽 한 유속분포와 유량 산정 결과를 ADV를 이용하여 정밀하게 측정한 결과와 비교하였다. 비교 결과 전체적으로 대수 법칙으로 외삽한 경우가 높은 정확도를 나타냈으며, 수표면 근처 미계측 영역에서는 1/6 멱법칙은 유량을 작게 산정하는 경향을 나타냈고, 하상 근처의 미계측 영역에서는 유량을 크게 산정하는 경향을 나타냈다. 이 결과는 기존 1/6 멱법칙을 활용한 하상 및 수표면 부근 미계측 영역 유량 추정 방법이 오차를 수반함을 의미한다. 따라서 ADCP 정지법 측정 방식을 사용할 경우, 대수 법칙이 1/6 멱법칙보다 정확한 상하부 미계측 유량 추정 결과를 보여주었으므로 대안으로 고려되어야 할 것이다. 또한 제방 근처 미계측 영역의 유량 측정 정확도를 높이기 위해서는 수심이 0.6 m 이상을 확보한 측선을 기준으로 유량을 산정할 경우 신뢰도 높은 유량 측정 결과를 보였다. 향후, ADCP 정지법 측정 방식에 비해 보다 많이 활용되고 있는 보트탑재 이동식 ADCP의 경우도 이와 같은 검증이 필요하다고 하겠다.
        10.
        2014.04 KCI 등재 서비스 종료(열람 제한)
        The water resources system of Jeju-do Island entirely depends on groundwater. This study is making a precision observation of baseflow, surface water, water shortage that might be vulnerable to climate change and drought in future. The field observation of baseflow discharges in Akgeuncheon stream has regularly been made with ADCP and ADC and Flowmate every two weeks for twenty-two (22) months (July 8, 2011 to April 27, 2013). This paper represent the results of calculating discharge of a number of hydraulic structures (broad-crested weirs) with comparing and has been calculated more accurate discharges with suitability of different observation methods. The average discharge has been observed 0.851 m3/s, whereas the average ADC and Flowmate is 0.709 m3/s. Meanwhile, stream discharge has been calculated 0.709 m3/s through the broad-crested weir equation. The discharge has calculated with the weir equation greatly changed according to even a small change in the water level. However, it showed a similar trend to one of the observed discharge. Although, in past there were generating errors caused by observers’ strides, vertical and horizontal flow velocity distribution when the average flow velocity had been measured, non-prismatic flow, turbulent flow and others in ADC. This study comes up with the weir equation is more suitable for the characteristics of Jeju-do could be presented through an observations of baseflow discharge.
        11.
        2014.04 KCI 등재 서비스 종료(열람 제한)
        Fixed Electromagnetic Wave Surface Velocimetry (Fixed EWSV) has been started to be used to measure flood discharge in the mountain stream, since it has various advantages such that it works well to continuously measure stream discharge even in the night time as well as very strong weather. On the contrary, the Fixed EWSV only measures single point surface velocity, thus it does not consider varying feature of the transverse velocity profile in the given stream cross-section. In addition, a conventional value of 0.85 was generally used as the ratio for converting the measured surface velocity into the depth-averaged velocity. These aspects could bring in error for accurately measuring the stream discharge. The capacity of the EWSV for capturing rapid flow velocity was also not properly validated. This study aims at conducting error analysis of using the EWSV by: 1) measuring transverse velocity at multiple points along the cross-section to assess an error driven by the single point measurement; 2) figuring out ratio between surface velocity and the depth-averaged velocity based on the concurrent ADCP measurements; 3) validating the capacity of the EWSV for capturing rapid flow velocity. As results, the velocity measured near the center by the fixed EWSV overestimated about 15% of the cross-sectional mean velocity. The converting ratio from the surface velocity to the depth-averaged velocity was 0.8 rather than 0.85 of a conventional ratio. Finally, the EWSV revealed unstable velocity output when the flow velocity was higher than 2 m/s.
        12.
        2014.02 서비스 종료(열람 제한)
        본 논문은 논산천 유역의 중소하천을 대상으로 평·갈수기와 홍수기로 구분하여 현장에서 유량 및 부유사량을 실측하고, 그 자료를 분석하였다. 평·갈수기의 유량과 부유사량 측정에는 프로펠러형 유속계 및 DH-48 수심 적분형 부유사 채취기를 사용하였고, 홍수기에는 전자파 표면 유속계 및 D-74 채취기를 각각 사용하였다. 이들 측정은 논산천 유역 내 4개의 중소하천 7개 측점에서 2012년 8월부터 2013년 8월까지 이루어졌고, 측정 자료 분석결과는 멱법칙의 유량-부유사량 관계식으로 도출하였다. 본 연구 결과는 수공 실무에 유용하게 사용될 것이다.
        13.
        2013.02 KCI 등재 서비스 종료(열람 제한)
        Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980’s. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002 , FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was 10.412 ㎥/s, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.
        14.
        2010.12 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 괴산댐 하류 달천에서 6가지 직접 유량 측정 방법-유속면적법, 봉부자법, ADCP이동측정법, ADCP정지 측정법, 전자파표면유속계, LSPIV-을 적용하고, 이를 댐 방류량 및 유속면적법과 비교함으로써 정확도를 상호 평가하였다. 이를 위해 2005년부터 2010년까지 실시된 총 39회의 유량측정결과가 분석되었다. 댐 방류량과의 비교 결과, 봉부자법을 제외한 나머지5가지 방법은 평균 6.2% 이내의 절대값오차를 나타냈다. 유속면적법과 다른
        15.
        2009.07 KCI 등재 서비스 종료(열람 제한)
        한강대교지점은 조석의 영향을 받고 노들섬으로 인해 흐름이 나누어지는 특수한 지형조건을 가지고 있으며, 홍수예보지점이고 한강유역의 유출량을 분석하는 대표지점이기도 하다. 따라서 정확한 수위-유량관계를 도출하기 위하여 많은 노력을 기울였으나 조석의 영향을 받지 않는 홍수기 이외의 기간에 대한 정확도의 확보가 곤란하였다. 이러한 문제를 해결하기 위한 대책으로 최근 자동유량측정에 관한 연구가 진행되었고, 실무에 적용되어 한강대교지점에서 실시간 유량자료의 획득이
        16.
        2005.10 KCI 등재 서비스 종료(열람 제한)
        ADCP는 음파의 도플러 효과를 이용하여 하천을 횡단하면서 단시간에 유속과 유량을 측정할 수 있는 장비이다. 본 연구는 현장 하천에서 ADCP를 이동식으로 운용하여 측정한 유속, 유량 자료를 동일한 지점에서 측정한 유속-면적법과 비교하여 ADCP를 이용한 유속, 유량 자료의 특성을 살펴볼 목적으로 수행되었다. ADCP에 의해 측정된 수심 분포는 직접 측심에 의해 측정한 수심 분포와 거의 일치하였다. ADCP로 측정한 유속은 순간적이므로 개별 연직유속분포
        17.
        2005.01 KCI 등재 서비스 종료(열람 제한)
        Several samplers using gravimetric methods such as high-volume air sampler, MiniVol portable sampler, personal environmental monitor(PEM) and cyclone were applied to determine the concentrations of fine particles in atmospheric condition. Comparative evaluation between high-volume air sampler and MiniVol portable sampler for PM10, and between MiniVol portable sampler and PEM was undertaken from June, 2003 to January 2004. Simultaneously, meteorological conditions such as wind speed, wind direction, relative humidity and temperature was measured to check the factors affecting the concentrations of fine particles. In addition, particle concentrations by cyclone with an aerodynamic diameter of 4 ㎛ were measured. Correlation coefficient between high- volume air sampler and portable air sampler for PM10 was 0.79 (p<0.001). However, the mean concentration for PM10 by high-volume air sampler was significantly higher than that by MiniVol portable sampler (p=0.018). Correlation coefficient between Minivol portable sampler and PEM for PM2.5 was 0.74 (p<0.001), and the measured mean concentrations for PM2.5 did not show significant difference. Difference of the measured concentrations of fine particle might be explained by wind speed and humidity among meteorological conditions. Particle concentration differences by measurement samplers were proportional to the wind speed, but inversely proportional to the relative humidity, though it was not a significant correlation.
        18.
        1998.12 KCI 등재 서비스 종료(열람 제한)
        In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Injection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzied that the estimated error of constant-rate-injection method is less than that of the slug-injection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can`t be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.
        19.
        1997.12 KCI 등재 서비스 종료(열람 제한)
        전자파를 이용한 하천수 표면 유속계를 하천 유량 측정에 사용하여 실용성과 문제점을 분석하였다. 표면 유속계의 평가는 선박 실험용 선형수조를 이용하여 수행하였다. 그 결고, 수직각을 20, 35, 45로 하였을 때 유속측정 평균값의 오차는 5.5% 이하였다. '95년 8월 26일 8~10시 사이에는, 남한강 여주대교 지점에서 홍수 유속을 측정하였다. 500m 길이의 교량에 대하여 23개 지점에서 측정한 결과, 표면 유속값은 약 2~4m/s였다. 수심평균