검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 22

        1.
        2024.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Climate chamber system is an essential facility for aerodynamic performance development of commercial vehicles to investigate air flow field characteristics in different climatic conditions. In particular, the analysis of airflow fields within the chamber system is an essential consideration for optimal design. In this study, the pressure characteristics and velocity uniformity in the test section area were predicted with blower impeller rotational speed using CFD. The velocity uniformity is affected by the distance from the blower nozzle outlet, reaching up to 72.7% at 695 RPM. The pressure differential between 300 RPM and 740 RPM shows an approximate difference of 2651 Pa, with a high-pressure distribution observed along the right side wall of the blower. These results are expected to be used as design data applicable for improving the performance of environmental chamber systems.
        4,000원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Air blower has been widely used in many industrial fields such as wind tunnel and large ventilation systems. Its performance is affected by operating conditions and system geometry of inpeller and duct, and these design parameter optimization is essential for the effective development. CFD analysis is carried out to investigate the air flow field characteristics with outlet total pressure in a blower system. Intake air into the impeller blade through the inlet is compressed, and then gradually discharged from the outlet with ascending total pressure, and predicted results are compared with test data. Especially this overall pressure difference in the blower system severely depends on the flow rate. These results are expected to be used as applicable design data for blower performance improvement.
        4,000원
        4.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To test a flameproof enclosure for the safety certificate, a reference pressure of explosion needs to be determined. However, the explosion pressure may be changed according to relative humidity of explosive gases. Therefore, the guideline on relative humidity should be recommended for measuring the explosion pressure for accurate and reproducible testings. This study examined the relationship of explosion pressure with relative humidity of hydrogen (31 vol %)-air and acetylene (14 vol %)-air mixture gases. The explosion pressures were measured by increasing the relative humidity of the gases by 10 % from dry state to 80 % in a cylindrical explosion enclosure of 2.3 L. on ambient temperature and atmospheric pressure (1 atm). The maximum explosive pressures were remained almost constant until the relative humidity reached 10 % for the hydrogen-air mixture and 20 % for the acetylene-air mixture. However, the maximum explosive pressures linearly decreased as the relative humidity increased. Based on the results of the study, it would be recommended to use 10 % relative humidity for the hydrogen-air mixture and 20 % for the acetylene-air mixture as the critical value in testing a flameproof enclosure.
        4,000원
        5.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To understand the effect of high pressure on nitrogen oxides (NOx) formation in water added methane flames, opposed nonpremixed Water-methane/air (H2O-CH4/air) flames are numerically studied with high initial pressure. With GRI 3.0 detailed kinetic mechanism, NOx emissions are predicted for various strain rates. Due to high pressure, the chemical species are distributed in a narrow region, which means the thickness of the flame is thin. This can be clearly seen with high strain rate. Elevated pressure increases maximum temperature of flames which results in increased NOx emission. Even with elevated initial pressure, NOx emissions for H2O added methane flames are significantly decreased compare to pure methane flame. In addition, increased strain rate is also significant factor for decreasing NOx emission. With detailed rate of production analysis, in case of high pressure, it is confirmed that NO2 pathway is the most dominant reaction pathway than any other pathways.
        4,000원
        6.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the air-side cooling capacity and pressure drop of an evaporator for a refrigerator unit were experimentally investigated. Using the calorimeter, the performance of the evaporator was verified by changing the fin shape, fin pitch, tube row and air flow rate. The experimental apparatus consisted of the calorimeter which functioned as a constant temperature and humidity chamber and the refrigeration cycle. In order to select the heat exchanger suitable for the evaporator, both air-side cooling capacity and pressure drop should be considered at the same time. From the evaporator performance test by pin type, wavy pin was selected. The optimal performance of the evaporator was observed at the fin pitch of 5 mm, the tube row of 6 row, and the air flow rate of 40㎥/min.
        4,000원
        7.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, FLUENT v.16.1 was used to investigate the compressible flow generated by the supersonic jet spewed from a high pressure tube. As the boundary condition for CFD (Computational Fluid Dynamics) analysis, the inlet temperature of air was constantly 300 K and the variation of JPR (Jet Pressure Ratio) were 5, 50, 100, 150 and the variation of tube diameter were 10, 20, 30 cm. As a result, it was confirmed that the effective range was increased as the JPR was higher, but it was confirmed that the effective range was lower than the JPR rise, and that the effective range was increased as the diameter was larger. Therefore, it is found that the tube diameter is more sensitive than the JPR among the influence factors of jet, and if the result of this study were reflected in the design of high pressure system, it will contribute to the design of the system for preventing the second accident.
        4,000원
        9.
        2013.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to determine the effect of the changes that occur in the leg muscle activity of unstable surface with different levels of air pressures. Three groups of college students have been placed randomly on unstable surfaces with different air pressures at group 1.0 psi (=36), group 1.4 psi (=40), and group 1.8 psi (=40). Using surface electromyography, the recruitment of the tibialis anterior, peroneus longus, and the gastrocnemius was measured. Maximal voluntary isometric contraction was measured at the different air pressures based on the manual muscle test, then normalizing the value to %maximal voluntary isometric contraction (%MVIC). The tibialis anterior muscle activity was significant change from the unstable surface with difference levels of air pressures between group 1.0 psi and 1.8 psi and between group 1.4 psi and 1.8 psi. peroneus longus muscle activity was significant changes in muscle activity occurred between 1.0 psi and 1.4 psi group and between 1.0 psi and 1.8 psi group. Gastrocnemius muscle activity was significant change in muscle activity occurred between 1.0 psi and 1.4 psi group and between 1.0 psi and 1.8 psi group. In conclusion it identify that 1.0 psi group is most effective on muscle activity than the other groups. These suggest that the rehabilitation or strengthening of patients with ankle injuries, balance exercise with low air pressure like 1.0 psi can be more effective.
        4,000원
        10.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 우리나라 온실 피복재의 결로 발생을 억제하는데 필요한 기초자료를 제공하기 위하여 토마토 재배용 실험온실의 포차변화 및 피복재에 발생하는 결로량의 변화를 분석하였으며 결과를 요약하면 다음과 같다. 실험온실의 경우 포차가 병 발생을 유발하기 쉬운 한계포차인 0.2kPa보다 더 크게 유지되어 온습도환경이 양호한 것으로 판단되었고 제습여부 결정을 위한 임계포차인 0.5kPa보다는 작게 나타나 제습은 필요한 것으로 판단되었다. 내부피복재의 표면온도는 외부온도와 커튼상부온도의 평균값 보다 약간 더 큰 것으로 나타났으며, 대체로 외부온도의 변화에 비례하여 변화하는 것으로 나타났다. 외부의 온도 및 습도 변화에 상관없이 커튼 상부의 습도는 거의 100%에 가까운 상대습도를 유지하여 결로 발생이 용이한 조건인 것으로 나타났다. 커튼하부의 습도는 내부습도의 큰 변화에도 불구하고 75~90% 정도로 안정된 값을 유지하였으며, 이는 온풍난방을 실시하여 온도를 15℃로 유지하였기 때문으로 판단된다. 실험조건 및 피복재의 종류에 따라 결로 발생량은 많은 차이가 있는 것으로 알려져 있다. 실험온실의 결로 발생량은 Seginer와 Kantz(1986)의 연구결과와 가장 잘 일치하는 것으로 나타났으나 다른 온실실험 결과들과는 약간의 차이를 보여주고 있기 때문에 앞으로 실험을 통해서 더 자세한 검증을 거친다면 우리나라 온실 피복재에 발생하는 결로량을 분석하는데 유용하게 활용될 수 있을 것으로 기대된다.
        4,000원
        11.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        관비재배 및 수경재배시 비료를 녹일 때 소요되는 시간과 노동력을 절감하고, 작업의 안전성 확보와 자동화를 가능하게 할 수 있는 장치의 개발을 위해 본 실험을 실시하였다. 실험은 세 종류로 수행되었다. 먼저, 효과적인 비료용해 방법을 구명하기 위해 수중펌프를 양액 통 속에 두고 양액 통의 입구에 삼베포를 깐 거름망을 설치하여 물을 스프레이하여 비료를 녹이는 방법(Spray), 수중프로펠러를 이용하는 방법(Propeller), 수중펌프를 양액 통 속에 넣어 물의 흐름을 만들어 주는 방법(Submerged), 에어컴프레서를 이용하여 양액 통 속에 공기흐름을 만들어 비료를 용해하는 방법(Airflow) 등 4개의 처리를 두고 실험하였다. Spray 처리에서 가장 시간이 짧게 소요되는 것으로 조사되었으나 농가가 실제로 적용하는데 어려움이 있어서, Spray 처리 다음으로 비료를 녹이는 시간이 짧고, 노동력을 절감할 수 있으며 양액제조 과정을 자동화 하는 것이 용이할 것으로 사료되는 Airflow 처리를 선택하였다. 두 번째 실험에서는 Airflow 처리에서 사용한 재질과 분지관수를 개선한 6지관 및 8지관 장치를 제작하여 비교 실험했는데, 6지관 장치가 비료용해시간이 짧고, 양액탱크의 입구 크기에 관계없이 사용이 가능하며, 제작이 용이하여 가장 효과적인 장치로 판단되었다. 세 번째 실험에서는 개발된 6지관 장치를 이용하여 비료를 용해하는데 소요되는 시간을 조사하여 경제성을 분석하였는데, 농가에서 수중펌프를 이용하여 비료를 용해하는 방법보다 시간은 1/8배 절약할 수 있으며 경제성이 큰 것으로 나타났다. 아울러 KNO3, Ca(NO3)2·4H2O, Fe-EDTA 등의 용해특성을 조사했다.
        4,000원
        12.
        2011.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        In this study, nano-sized tin oxide powder with an average particle size of below 50 nm is prepared by the spray pyrolysis process. The influence of air pressure on the properties of the generated powder is examined. Along with the rise of air pressure from 0.1kg/cm2 to 3kg/cm2, the average size of the droplet-shaped particles decreases, while the particle size distribution becomes more regular. When the air pressure increases from 0.1kg/cm2 to 1kg/cm2, the average size of the dropletshaped particles, which is around 30-50 nm, shows hardly any change. When the air pressure increases up to 3kg/cm2, the average size of the droplet-shaped particles decreases to 30 nm. For the independent generated particles, when the air pressure is at 0.1kg/cm2, the average particle size is approximately 100 nm; when the air pressure increases up to 0.5kg/m2, the average particle size becomes more than 100 nm, and the surface structure becomes more compact; when the air pressure increases up to 1kg/cm2, the surface structure is almost the same as in the case of 0.5kg/cm2, and the average particle size is around 80- 100 nm; when the air pressure increases up to 3kg/cm2, the surface structure becomes incompact compared to the cases of other air pressures, and the average particle size is around 80-100 nm. Along with the rise of air pressure from 0.1kg/cm2 to 0.5kg/cm2, the XRD peak intensity slightly decreases, and the specific surface area increases. When the air pressure increases up to 1kg/cm2 and 3kg/cm2, the XRD peak intensity increases, while the specific surface area also increases.
        4,000원
        13.
        2009.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to analyze the variations of air temperature, relative humidity and pressure in a low pressure chamber for plant growth. The low pressure chamber was composed of an acrylic cylinder, a stainless plate, a mass flow controller, an elastomer pressure controller, a read-out-box, a vacuum pump, and sensors of air temperature, relative humidity, and pressure. The pressure leakage in the low pressure chamber was greatly affected by the material and connection method of tubes. The leakage rate in the low pressure chamber with the welding of the stainless tubes and a plate decreased by 0.21kPa·h-1, whereas the leakage in the low pressure chamber with teflon tube and rubber O-ring was given by 1.03kPa·h-1. Pressure in the low pressure chamber was sensitively fluctuated by the air temperature inside the chamber. An elastomer pressure controller was installed to keep the pressure in the low pressure chamber at a setting value. However, inside relative humidity at dark period increased to saturation level.. Two levels (25 and 50kPa) of pressure and two levels (500 and 1,000sccm) of mass flow rate were provided to investigate the effect of low pressure and mass flow rate on relative humidity inside the chamber. It was concluded that low setting value of pressure and high mass flow rate of mixed gas were the effective methods to control the pressure and to suppress the excessive rise of relative humidity inside the chamber.
        4,000원
        14.
        2020.05 KCI 등재 서비스 종료(열람 제한)
        With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30% , thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.
        15.
        2019.10 KCI 등재 서비스 종료(열람 제한)
        Rehabilitation work is required to increase well productivity, which decreases with the elapsed time of pumping owing to the clogging of the water well. Clogging causes not only a reduction in the well productivity but also a deterioration of the water quality. For unclogging and rehabilitating wells, several techniques are used such as brushing, air surging, surge blocks, and gas impulse. In this study, the high-pressure air impulse technique, which effectively and economically rehabilitates wells, was applied to a riverbank filtration site in Korea for the same objective. At most of the wells, the hydraulic parameters (transmissivity, storage coefficient, and specific capacity) were increased by the application of the high-pressure air impulse technique. The well loss change values also indicate an increase in the hydraulic parameters by the air impulse implementation. Thus, the high-pressure air impulse technique can be efficiently and economically applied to water and riverbank filtration wells for rehabilitating the decreased productivity.
        16.
        2018.06 KCI 등재 서비스 종료(열람 제한)
        In this study, using coke dust from ironwork, the pulse pressure on a pulse air jet bag filter was investigated considering the influence of the pressure loss due to filtration velocity and pressure intervals. The research on the optimal pulse pressure prediction of a pulse air jet type bag filter using coke dust showed the following results. Pressure loss volatility produced by the pulse pressure under low dust concentration(0.5, 1 g/m3) and low face velocity(1.25 m/min) was less than 10 mmH2O. This suggests that the pulse pressure has a low impact on the pressure loss. In contrast, pressure loss volatility under high dust concentration(3 g/m3) and high face velocity(1.75 m/min) was 25 mmH2O. Therefore, pulse pressure with high dust concentration and high face velocity has a strong influence on the pressure loss volatility, compared to the condition of low dust concentration and low face velocity. The optimal pulse pressure of inlet dust concentration(0.5 g/m3) was 6 kg/cm2 under the same face velocity(1.75 m/min). As concentration increased from 1 to 2 g/m3, the pulse pressure gradually reached 5 kg/cm2 thus indicating that the pulse pressure(5 kg/cm2) is pertinent at a high concentration(3 g/m3). The pulse intervals: 20, 25 and 30 sec, which are relatively longer than 10 and 15 sec, corresponded to high pressure loss volatility produced by the pulse pressure. Furthermore, low pressure loss volatility was noted at 5 kg/cm2 of the overall pulse pressure.
        17.
        2013.09 KCI 등재 서비스 종료(열람 제한)
        Desorption characteristics of VOCs were investigated for the effective recovery of gasoline vapor. The adsorption capacity and desorption capacity were excellent at relatively low temperatures. The differences in the desorption capacity were not large in the condition; desorption temperature 25℃, desorption pressure 760 mmHg, inlet air flow rate 0.5 L/min, but were relatively great in the condition; desorption temperature 0℃, desorption pressure 60 mmHg, inlet air flow rate 1.0 L/min. The desorption ability of pentane was increased to about 81.4%, and the desorption ability of hexane was increased to about 102%, also the desorption ability of toluene was increased to about 156.7% by changes of temperature, pressure, inlet air flow rate in the experimental conditions. The optimum desorption condition for the effective recovery of VOCs was in the conditions; desorption temperature 0℃, desorption pressure 60 mmHg, inlet air flow rate 1.0 L/min.
        18.
        2013.06 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        The capacity of a pressure fan can be designed based on the air flow resistance of containers packed with fruits and vegetables in a pressure cooling system. This study was conducted to develop an air flow resistance model that was dependent on changes in the air flow rate and the method of stacking containers. The air flow resistance of a container packed with uniformly shaped balls was 1.5 times greater than the sum of the air flow resistance of a vacant container and that of a wire net container packed with only balls. In addition, the air flow resistance increased exponentially as the width of the stacks increased; however, the air flow resistance did not increase greatly as the length and height of the stacks increased, which indicates that the air flow resistance is primarily influenced by the width of the stack in the air flow direction. The air flow resistance in two lines of stacking was up to 17% less than that of the width of the stack. It was also possible to determine the air flow resistance using a function of the air flow resistance through a single container and develop a prediction model. A prediction model of air flow resistance that is dependent on the stacking method and the air flow resistance of a single container was developed.
        19.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 비접촉식 충격-반향 기법을 이용한 콘크리트 구조물의 손상 탐지에 있어서 비용 효율성을 높이기 위한 다이나믹 마이크로폰의 적용 가능성에 대하여 알아보았다. 박리 손상이 인공적으로 모사된 콘크리트 슬래브 실험체에 대하여 비접촉 충격-반향 실험을 다이나믹 마이크로폰을 이용하여 수행하였으며 저비용 센서 시스템의 손상 탐지 성능을 분석하였다. 실험 결과 다이나믹 마이크로폰으로 의미있는 신호의 측정이 가능하며, 또한 콘크리트의 박리 손상도 고성능 음압 센서만큼 명확하게 검출 가능하다는 것을 알 수 있었다.
        20.
        2011.01 KCI 등재 서비스 종료(열람 제한)
        The new empirical static model was constructed on the basis of dimension analysis to predict the pressure drop according to the operating conditions. The empirical static model consists of the initial pressure drop term (N dust = ω0υf / P pulse t) and the dust mass number term (Δp initial), and two parameters (dust deposit resistance and exponent of dust mass number) have been estimated from experimental data. The optimum injection distance was identified in the 64 experimental data at the fixed filtration velocity and pulse pressure. The dust deposit resistance (K d), one of the empirical static model parameters got the minimum value at , d=0.11m, at which the total pressure drop was minimized. The exponent of dust mass number was interpreted as the elasticity of pressure drop to the dust mass number. The elasticity of the unimodal behavior had also a maximum value at , d=0.11m, at which the pressure drop increased most rapidly with the dust mass number. Additionally, the correlation coefficient for the new empirical static model was 0.914.
        1 2