검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 220

        22.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The cooking-generated particles are major indoor sources of air pollution. Recently, the performance of the range hood is focused on particle removal performance. Range hood with an auxiliary air supply system can improve the fine and ultrafine particles removal efficiency by making a supply air during cooking activities. The particles were measured in the experimental building by varying ventilation types. Only operating range hood during the cooking activities was not enough to reduce the cooking-generated particles. Despite operating range hood systems, fine and ultrafine particle concentrations were maintained when cooking was finished. The range hood with a make-up air supply system can reduce the indoor particle concentration below background conditions when those systems were operated after cooking. In this study, the assessment of cooking-generated particle removal efficiency of the range hood with an auxiliary air supply system was conducted. The removal efficiency of ultrafine particles showed trends similar to the removal efficiency of fine particles.
        4,000원
        23.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        천연석재의 고갈로 인해 인조암은 자연암의 대체소재로서 2000년대 후반부터 꾸준히 공동주택에 적용되고 있다. 인조암을 이용한 폭포는 다양한 형태로 바위연출이 가능하며, 인공지반에 설치시 자연암에 비해 구조 자체에 부담을 주지 않기 때문에 구조 설계에 유리한 장점이 있다. 인조암폭포는 외부공간에서 입면적으로 도드라지는 시설물로서 자연암과 유사한 경관조성과 지속가능한 유지관리성이 충분히 고려되어야 한다. 인조암폭포를 자연암과 유사한 경관을 연출하기 위해서는 형태, 질감, 색채에 대한 고려가 필요하다. 형태에 있어서 고려사항은 입체감 있는 매스분할, 모서리의 각이 돋보이는 형태, 자연스러운 크랙 표현이며, 질감에 있어서 고려사항은 다양한 기법에 의한 질감표현, 음영에 의한 입체감 표현이며, 색채에 있어서 고려사항은 자연암에 유사한 색상연출, 인조이끼 활용이다. 부가적으로 포트에 의한 식재, 인접 녹지에 덩굴성 식물 식재, 미스트분수의 활용으로 인조암의 단점을 보완함으로써 입주민의 만족도를 높일 수 있을 것이다. 지속적인 유지관리를 위해서는 변색, 녹조에 대한 고려가 필요하다. 변색에 있어서 고려사항은 자연스러운 변색을 위해 도트기법에 의한 도색이 필요하며, 백화발생 구간에는 인조이끼 처리가 필요하다. 인조암을 활용하여 폭포와 연계된 수조경계부, 수조바닥면을 일체화하여 조성할 경우 녹조 발생시에 청소가 용이하여 유지관리가 용이하게 된다.본 연구에서 제안한 설계 및 시공단계에서 경관 및 유지관리를 고려한 계획은 인조암폭포의 품질편차를 줄이고 입주민의 선호도가 높은 특화시설을 조성하기 위한 기초자료로 활용이 가능할 것이며, 설계 및 시공 단계별로 고려해야할 세부적인 내용을 제안하였다는 점에서 의의를 가지고 있다.
        4,500원
        24.
        2020.06 구독 인증기관 무료, 개인회원 유료
        본 연구는 기존 분양⋅임대혼합아파트와 관련된 연구를 바탕으로 문헌조사를 실시하고, 현황과 문제점, 대책에 대해 논의해보고자 한다. 사회적 혼합이란 주거지 개발의 방향을 다양한 계층의 주민들이 한 장소에서 함께 거주하도록 도모한다는 뜻으로 ‘소셜믹스(Socail Mix)’라고도 불린다. 최근 우리나라에서는 일반 분양아파트와 공공임대아파트를 한 공간에 혼합하여 건설하는 소셜믹스 아파트 단지가 대규모로 지어지고 있다. 사회적 통합에 기여하고자 하는 긍정적 목적에도 불구하고 현재의 소셜믹스 단지는 입주민 간의 갈등과 임대아파트 주민의 사회적 배제현상까지 나타나 진정한 통합을 이루고 있지 못하다. 이러한 상황을 개선하기 위해서는 입주민간의 교류를 강화하고 지역공동체 의식을 함께 갖도록 하는 기회가 많이 마련돼야 할 것이다. 향후 소셜믹스 아파트 단지 거주자를 중심으로 한 질적 연구를 통해 실질적인 대책의 강구가 필요하다.
        4,500원
        25.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2018년 여름의 폭염은 기상관측을 시작(1907년 10월 1일)한 이래 111년 만에 가장 높은 기온을 기록하였는데, 서울은 39.6℃를 기록(2018년 8월 1일)하여 종전의 기록인 38.4℃(1994년 7월 24일)를 뛰어넘었다. 열섬현상으로 인해 도시의 온도가 상승하고 하절기 열쾌적성이 저하됨에 따라 하절기 열환경 개선에 대한 연구가 지속적으로 진행되고 있다. 본 연구의 목적은 조경공 사 전·후의 온도저감 및 외부공간 이용자가 느끼는 열환경 개선에 대하여 정량적으로 검증하여 설계 및 시공단계에서 활용할 수 있는 기초적 자료를 제공하고자 하였다. 연구결과는 다음 과 같다. 미기후 실측에 의한 측점별 조경공사 전·후의 온도저감을 비교 분석한 결과, 오전 10 시 조경공사 전 평균온도는 34.5℃이며, 조경공사 후 평균온도는 32.5℃로 2.0℃온도저감 효과가 있는 것으로 분석되었으며, 오후 2시 조경공사 전 평균온도는 37.5℃이며, 조경공사 후 평균 온도는 35.9℃로 1.6℃ 온도저감 효과가 있는 것으로 분석되었다. 오후 5시 조경공사 전 평균온 도는 33.8℃이며, 조경공사 후 평균온도는 31.2℃로 2.6℃ 온도저감 효과가 있는 것으로 분석되었다. 연구결과의 활용방안으로 정량적인 연구방법과 결과는 디자이너의 직관적인 조경설계에 객관성을 부여하는 기초자료로서 활용이 가능할 것이다.
        4,000원
        26.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the importance of air filters used in air purifiers and ventilation systems is emphasized in Korea. As a result, air filter test reports are required by users to ensure the removal efficiency of particulate matter. However, the tests are conducted for the filter material alone, which lead to a possible discrepancy between the test report and actual efficiency when applied to actual devices. Therefore, in this study, the removal efficiency data of the filter test reports were compared with actual filter efficiency data after application to the ventilation systems for some ventilation systems in the market. For ventilation system A, the field test results using filter leakage test method were slightly lower than those in the test report but nearly the same. For ventilation system B, the field test result was much higher than reported in the test report. This was due to the broad range of particle sizes measured using the filter leakage test method. The field tests using the particle counter method showed that the removal efficiency of ventilation system A for 0.3 μm was under 50% which translates to less than half of those of the filter test reports. For ventilation system B, the removal efficiency was 15%~21%. much lower than reported in the filter test reports. The lower removal efficiencys are mainly assumed to be caused by leakage of the filter installation among other factors. Therefore, the field test methods for the particulate matter removal efficiency of ventilation systems should be established to verify actual efficiency and improve the efficiency in the future.
        4,000원
        27.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study’s results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building’s stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system’s internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.
        4,300원
        28.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 아파트단지 내 불량한 식생공간을 보수하거나 다양한 식생으로의 재조성하여 녹색의 질을 높이기 위한 방안으로 아파트 단지 내 조경관리 현황을 조사하고 식재지반인 토양상태를 파악하여 합리적인 계획 수립을 위한 기초 자료화 하는 것을 목적으로 하였다. 아파트 준공시점을 기준으로 동일한 규격의 수목이 동시에 식재되는 것을 감안해 준공연도를 5년 단위로 구분하고 식재기간 경과에 따른 수목생장과 토양성분의 차이를 분석하였다. 전체 조사대상지 9개소에 모두 식재된 수종 중 침엽수 4종과 활엽수 4종의 생육상태를 조사하여 한 결과 침엽수 중 가이즈까향나무 소나무, 활엽수 중에서는 꽃사과나무가 5년 이상의 식재기간이 경과되었을 때 가장 생육이 좋았다가 10년 이상 되었을 때는 생장이 감소하였다. 측백나무와 단풍나무는 10년 이상 된 지역의 수목이 생육이 가장 좋아 비교적 생장을 위한 기간이 많이 요구되는 수종이었다. 수목은 식재되어 있으나 지표면이 나지가 되어있는 지점의 토양경도를 분석한 결과 준공 후 5년 이상이 되면 20㎜ 이상의 답압 된 상태가 되는 것으로 조사되었고 토양이화학성은 준공 초기부터 지속적으로 pH는 높고 유기물함량은 비옥한 토양의 1/3 정도로 추가 시비가 필요한 상태였다. 본 결과를 토대로 나지부분의 재식재시에는 식재지 주변 배수로 설계와 토심 50㎝ 정도를 객토하고 왕겨 등의 유기질재료를 혼합하는 정도의 토양 개량 계획을 추가하여 수목 하부에 지피식물을 식재하는 것만으로 토양의 답압과 토양건강성을 회복하는 방안이 될 것이라고 사료된다.
        4,000원
        29.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Outdoor air pollution with particulate matter has become more severe in Korea. Ambient particle concentration affects the indoor environment through various routes through building envelopes. In this study, we investigated particle exposure in residential buildings. Indoor and outdoor particle sources determined the indoor concentrations and particle exposure. This paper measured indoor particles and CO2 concentrations in two different apartment buildings and conducted the survey for 24 hours. The I/O ratio of the occupant awake period was higher than the asleep period. The I/O ratio in the awake period is 0.93-3.65, while the I/O ratio in the asleep period is 0.31- 0.76.Indoor peak events such as cooking or cleaning temporarily increase the I/O ratio and emit the indoor particle sources. Decay rate constant is 0.49-6.84 (1/h) in the indoor peak events during the operation of the exhaust hood and natural ventilation. The size range of 0.3-0.5 μm size is over half for the proportions of emitted particles (55.6%). Daily exposure is divided into indoor sources (45.2%) and outdoor sources (54.8%). We found the differences for the proportion of particle exposure. The ratio of daily exposure in particles for 0.3-0.5 μm size is 43.1 (indoor)/ 56.9 (outdoor) %. However, indoor sources are higher than outdoor sources for the ratio of daily exposure in particles for the 0.5-10.0 μm size.
        4,000원
        32.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : As road pavement design in an apartment complex varies from one site to another, it is practically difficult to calculate and estimate the traffic volume of construction vehicles. Therefore, this study introduces a methodology to estimate the number of construction vehicles and use it as an indicator to evaluate the conditions of road pavement in an apartment complex. METHODS: Through a literature review and site survey, the operational status of the construction vehicles passing through the site was identified, and the factors affecting the number of construction vehicles were analyzed. The methodologies used to estimate the number of construction vehicles were verified by calculating the Cumulative Load Prediction Index (CLPI), which is a predictive index of the cumulative load on each path. By using this index, the traffic volume of construction vehicles can be estimated based on the number of households in an apartment complex. To prove this definition, we examined the surface and core conditions, and compared the results against the predicted values. RESULTS : By comparing the Cumulative Load Prediction Index with the crack rate on the pavement surface, we obtained a correlation coefficient of 0.92. Furthermore, the analysis indicated that the core condition rate would decrease as the Cumulative Load Prediction Index increased. This correlation between the Cumulative Load Prediction Index, and the pavement surface and core status demonstrates that the traffic volume can be estimated by considering the number of households. CONCLUSIONS: The Cumulative Load Prediction Index presented in this study is a suitable indicator for estimating the conditions of the road pavement in an apartment complex by considering the number of households in the complex, even if the construction processes and characteristics vary.
        4,200원
        33.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out to examine the effect of the presence of non-structural walls in apartment buildings subjected to an earthquake. It was believed that the presence of non-structural walls, which has not been considered in the structural design process, was usually built together with structural walls and this led to significant damages to the apartment buildings in Pohang earthquake, 2017. In this study, a 22-story apartment building was selected and modeled to simulate the seismic behavior due to earthquakes. The story drift, performance point, and compressive strain in the walls were the main parameters to evaluate the seismic performance with the presence of non-structural walls.
        4,000원
        34.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        국내 고층 아파트의 구조시스템은 크게 다수의 벽체가 분산적으로 배치되어 있는 내력벽 시스템과 중앙 코어벽 시스템으 로 구분할 수 있다. 각각 시스템에 따른 횡방향 거동을 분석하기 위해 본 연구는 국내 고층 아파트 중 대표적인 평면을 갖는 대상 건물을 선정하고, 비선형 정적해석을 수행하여 붕괴메커니즘을 살펴보았다. 비선형 정적해석을 통해 도출된 힘-변위 관계로부터 지진응답에 있어서 중요한 요소인 초과강도계수 및 연성도계수를 산정하여 반응수정계수를 평가하였다. 중앙 코어벽 시스템은 연성도는 작지만, 풍하중에 의해 지배되어 초과강도가 크게 산정돼 초과강도계수에 의해 반응수정계수가 산정되었고, 내력벽 시스템은 벽량이 많아 연성도가 크기 때문에 상당힌 큰 반응수정계수가 산정된다.
        4,000원
        35.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Many air purifiers have been developed and released with increasing PM. In generally, the performance of air purifiers has been evaluated in the environment chamber by relevant standards. However, as there is a lack of information about air cleaning performance of air purifier in the living area, consumers have difficulty with product selection. In this study, five air purifiers were tested in apartments with different structures. In order to examine the effect of air purifiers, we assumed 3 cases such as inflow of pollutants from outdoors by ventilation, smoking patterns of residents, and cooking methods (e.g., frying fish). The evaluation results showed that the efficiency of air purifier products D and B of the 3-stage configuration (pre-filter + HEPA filter + activity carbon) was the best in most experiments. In the case of the ionizer type E product, the efficiency was very low and, at times, had increased the particulate matter indoors. Considering the cost-performance ratio, it is most reasonable to use an air purifier comprising a pre-filter and a HEPA filter without an additional configuration.
        4,200원
        36.
        2019.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        스프링클러설비에서 누수 하자가 발생되면 설비의 작동을 멈추는 경향이 많고 이는 입주자의 안전에 많은 지장을 초래하게 되며, 누수피해로 재산상의 손실도 발생하게 되므로 스프링클러설비는 화재진압 성능뿐만 아니라 내구성도 높아야 할 것이다. 동관 부식은 스프링클러설비 배관에서 주로 나타나는 특이한 현상으로서 그 동안 제시된 여러 학설들과 법원의 판단 등을 종합하여 검토한 결과, 동관의 부식은 매우 복합적인 요인에 의해 발생되고 있고, 하자보수 방법의 결정요인의 핵심은 보완시공을 통한 부식억제의 가능성 여부를 판단하는 것인데 실증적용 사례 연구 등을 통한 결론을 도출 하였다. 또한 스프링클러설비의 설비의 내구성 강화에 대한 법규적 미비점에 대해서도 연구를 통한 개선방안을 제시하여 향후 하자발생을 줄이고자 하였다.
        7,700원
        38.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        통합과 포용력이 사회의 주요한 이슈로 부각되면서, 사회적 약자인 노년층과 저소득 계층의 여가 활동을 충족시키는 도시계획시설에 대한 역할이 주목받고 있다. 본 연구는 노원구 △△영구임대주택 거주민을 대상으로 옥외활동 시설에 대한 이용 실태와 주요 공간 이용에 따른 사회적 관계망 형성 효과를 분석하였다. 분석은 빈도, t-분석 그리고 사회연결망 분석 방법을 활용하였다. 분석결과, 단지 내 공간 및 시설이용 빈도는 복지관(36.9%), 나팔공원(17.9%), 텃밭(10.2%)의 순으로 나타났으며, 1인이 교류하는 이웃의 수는 텃밭(13.44명), 나팔공원(6.47명), 복지관(5.13명) 이용자의 순으로 나타났다. 특히, 텃밭 이용자는 이웃 간 교류의 범위가 가장 넓게 나타났으며, 다양한 그룹을 통해 정보의 교류가 활발히 일어나고 있었다. 관계의 질적 수준 역시 일반적인 교류의 수준을 넘어 정보 교류 및 문제 발생 시 적극적으로 도움을 주고받는 상호 부조의 관계를 유지하는 것으로 확인되었다. 반면 산책, 휴식, 운동 등의 여가 활동이 이루어지는 나팔공원과 교육 활동이 제공되는 복지관의 경우 이용자들 간 교류의 범위가 좁고 집중화된 정도가 소수 그룹에 한정되었다. 본 연구는 영구임대주택에 거주하는 취약계층을 대상으로 주민들의 자발적인 교류와 지속적인 옥외활동을 촉진하는 공간 및 시설에 대한 사회적 기능을 밝혔다는데 의의가 있다.
        4,200원
        39.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to evaluate thermal performance using the ASTR method. Its findings are as follows: 1) The measured U-Values of 49A type and 59A type walls were almost the same as the theoretically calculated values. 2) One notable phenomenon for both walls was that the interior surface temperatures of the channels attached to corners were up to 10.4% lower than that of the cross of the wall, even though they consisted of the same materials. This is due to the surface temperature drop caused by the thermal bridge. 3) The surface temperatures of the thermal bridge were converted into U-Values. The U-Value of the top left corner on the 59A type house was 1.044W/m²K, and of the bottom right corner on the 49A type house was 0.959W/m²K. Therefore, the thermal performance of the thermal bridge area was decreased after construction. 4) Differences were found in the results of comparing heat transfer analysis simulation data and measured data. A maximum difference of 12.4% occurred in the top left corner on 59A type, and of 7.6% occurred in the bottom right corner on 49A type. 5) The results of a heat transfer analysis simulation showed that the temperature of both 49A type and 59A type top right corner were the lowest, but in-situ measurement results were the lowest in the bottom right corner on 49A type and in the top left corner on 59A type. These results are considered to be due to the occurrence of thermal bridges and a deterioration in the construction quality.
        4,000원
        40.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the urban population continues to increase, cities grow through the expansion of high-rise and high-density residential areas, which demand good living environments to improve citizens’ quality of life. This study is based on the apartment type proposed by Moon Soo-young(2011) in accordance with the layout pattern of green spaces in three apartment complexes located in Dalseo-gu, Daegu Metropolitan City. The purpose of this research is to discover the causes of the high nutritional rate and successful planting method, as well as to suggest a plan to improve the planting structure(general complex, built apartment). According to the study results, the green area ratio of the study was the highest with 44.7% of the total area, followed by Wolbahil state(center type) with 30.3%, and the Bible Jeongnam Town(type of arrangement around buildings) with 27.3%. Shared facility centers were placed outside the apartment buildings in common with the type of arrangement around the buildings and the type of centering arrangement, and the coverage rate in the apartment complexes increased. There are many underground parking lots in the vicinity of the buildings; the center type of the buildings and the parking lots for the disabled are located underground. In general, residents use the underground parking lot, and the ground greenery ratio is higher than other types. Through the analysis of the facilities in the complex according to the type, we found the cause of high green ratio and good planting method and suggested an improvement plan for the general and constructed apartments. In the general apartment complex improvement plan, it is possible to increase the green area by minimizing the single-story buildings such as the shared facilities center and arranging these facilities in the apartments. The number of entrances is reduced due to the connectivity between underground parking lots. Reducing the area of the road within the complex can reduce the number of green spaces. It is important that water pipes are laid mainly under broad-leaved trees and that the plant structure is multi-layered. In order to estimate the construction of the apartment, we propose a method to construct the green space in three dimensions by using methods such as wall greening and rooftop greening. It is possible to utilize enough spaces to waste through the plant materials. In the plant structure, a cluster planting was arranged and the shrubs and plants were placed in the complex.
        4,200원
        1 2 3 4 5