검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 57

        21.
        2018.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It is necessary to develop a mobile water production system in order to provide stable water supply in case of disasters such as floods or earthquakes. In this study, we developed a modular mobile water production system capable of producing water for various uses such as domestic water and drinking water while improving applicability in various raw water sources. The water production system consists of three stages of filtration (sand filtration - activated carbon filtration - pressure filtration) to produce domestic water and an additional reverse osmosis process to produce drinking water. In laboratory and field experiments, the domestic water production system showed excellent treatment efficiency for particulate matter, but showed limitations in the treatment of dissolved substances such as dissolved organic matter. In addition, ultraviolet irradiation was considered as additional disinfection step, because it does not form precipitates of manganese oxides after disinfection. Reverse osmosis process was added to increase the removal efficiency of dissolved substances and the treated water satisfied drinking water quality standards. Fluorescence analysis of dissolved organic matter showed that the fulvic acid-like substances in raw water was successfully removed in the reverse osmosis process. The mobile water production system developed in this study is expected to be used not only in water supply in case of disaster, but also widely used in islands and rural area.
        4,200원
        22.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 냉동공조용 열교환기 내 스케일 형성으로 열전달 과정에서 열저항으로 작용하여 냉동공조시스템의 냉각성능이 떨어져 이를 해결하기 위해 전기분해 원리를 이용하여 배관 내 스케일을 자동 제거하는 시스템을 개발하여 그 성능을 실험을 통해 확인하고자 한다. 이전까지는 배관 내 스케일을 2∼3 년에 한번씩 브러시나 분사 노즐에 의해 기계적으로 배관 내를 청소를 하거나 화학약품을 이용하여 세관하였다. 이러한 세관은 시간이 경과하면 또 관이 오염되어 전열성능이 떨어지고 냉각장치의 운전을 정지하여 반복해야하는 여러 가지 문제점을 안고 있었다. 따라서 시스템의 정지없이 전기분해 원리를 이용하여 만들어진 처리수를 순환시킴으로서 스케일의 원인물질은 Ca, Mg, SiO2를 고형물 형태로 석출시켜 배관계 외부로 배출시킴으로서 배관내 스케일 발생을 차단하고 기 형성된 스케일을 제거하여 배관의 전열 성능을 유지하고자 하는 것이다. 실험한 결과, 새 배관의 열전달율을 100으로 기준할 경우, 스케일이 형성된 배관의 열전달율은 86.66%이었으며, 스케일이 형성된 배관을 1개월 동안 처리수를 가동했을 경우 열전달율은 90.5%의 수준까지 회복되었으며, 2개월간 운전한 경우 97.86%의 수준까지, 3개월 운전했을 경우 98.72% 까지 열전달율이 회복되었다. 비교적 짧은 실험기간이지만 배관내 형성된 스케일의 제거효과를 파악하였으며, 전열성능에도 영향을 미치고 있음을 확인하였다.
        4,000원
        23.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        쌈채소 수경재배 시 문제가 되는 체내 질산염 함량을 효과적으로 저감시키기 위해 폐쇄형 생산시스템에서 1) 저광도(100μmol·m-2·s-1내외) 조건에서의 수확 7일 전 양액조성 방법과 2) 질산염 저감을 위한 적정 광도 및 수확 전 적정 양액결제시기를 구명하기 위해 수행하였다. 청치마상추에서 수확 7일 전 양액조성 방법 중 양액결제(양액공급 중단) 처리와 양액내 질소 공급원으로 탄산 암모늄[(NH4)2CO3]을 사용한 처리는 처리기간 동안 체내 질산염 함량을 감소시켰으나, 생체중, 엽면적 등의 생육량도 감소되었다. 하지만 100μmol·m-2·s-1조건에서 수확 7일전 양액내 NO3-N 비료를 결제하여 조성하거나 배양액 농도를 1/2배액으로 낮추어 공급함으로써 외적 품질 및 생육량의 저하없이 질산염 함량은 감소되었다. 또한 수확 전 양액결제시기 및 적정 광도를 구명하기 위해 실험을 수행한 결과, 100, 200, 및 300μmol·m-2·s-1 의 3수준의 광조건 모두 수확 7일 전 양액결제시에 체내 질산염이 가장 낮게 나타났으며, 특히 300μmol·m-2·s- 1의 광도와 수확 7일 전 양액결제 처리시 식물체내 질산염의 빠른 저감효과를 볼 수 있었으나 생육량의 감소를 가져왔다. 수확 3일 전 양액결제 처리에 의해 300μmol·m- 2·s-1 광도에서 체내 질산염 함량은 2,021ppm에서 480ppm로, 200μmol·m-2·s-1 광도에서 3,018ppm에서 1,035ppm로 감소되었으며, 외적 품질의 저하 없이 생육량이 높으면서 동시에 짧은 시간 동안 식물체내 질산염의 저감 효과를 볼 수 있었다. 수확 7일 전 양액결제 처리는 체내 질산염의 저감효과가 컸던 반면 엽중, 엽면적 등의 생육 감소를 가져왔는데, 200과 300μmol·m-2·s-1의 광조건에서 수확7일 전 양액결제시 수확 3일 전 양액결제보다 엽중은 20~35%, 엽면적은 16~31% 낮은 값을 나타내었다. 광도 및 양액결제시기에 따른 비타민 C 함량을 분석한 결과 100, 200보다 300μmol·m-2·s-1 에서 수확 3일과 5일전 양액결제 처리시 비타민 C 함량이 가장 높게 나타났다.
        4,000원
        24.
        2017.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        배타적경제수역의 난파물 제거에 관한 연안국의 개입권한과 절차, 비용회수 등에 관하여 규정한「난파물제거협약」이 채택되어 국제적으로 발효되면서 각 연안국은 자국의 실정을 감안하여 난파물 처리규정을 국내법으로 수용 하였다. 우리나라의 경우에도 「해사안전법」을 개정하여 영해뿐만 아니라, 배타적 경제수역의 난파물, 즉, 항행장애물까지 처리할 수 있는 근거를 추가적으로 마련하여 국제규범에 따른 해양관할권을 적극적으로 행사하려는 노력을 하고 있다. 그런데 항행장애물 제거와 관련된 현행 국내법규와 해역관할청의 대응역량은 몇가지 실행상 문제점을 가지고 있다. 예컨대, 항행장애물 제거역량을 적절하게 반영하지 않은 채 해역관리청에 업무가 위임되어 있는 것과 방치폐선, 해양표류물, 침몰선박 등 항행장애물 유사용어 및 제거규정을 규정한 다수의 법규들이 병존하면서 주관부서간 업무혼선이 야기되고 있는 것이다. 따라서 현행 항행장애물 처리제도의 문제점에 대한 개선방안으로 관련 법제의 적절한 정비와 주관부서의 현실적 구난능력을 감안한 업무조정이 필요하다. 구체적으로는 해사안전법 관련규정을 개정하여 구난능력을 갖춘 전문 민간기관·단체에 업무를 위탁하고, 중장기적으로 구조와 구난을 통합하여 일원화하는 방향으로 관련 법제를 정비할 필요가 있다.
        5,700원
        25.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a system was developed that can evaluate the radon gas removal efficiency of air cleaner filters. The system has three acrylic chambers connected in series;: the 1st chamber, the filter chamber and the 2nd chamber. In the 1st chamber, a radon source and an air pump were installed to create an environment with a constant radon concentration. Radon concentration in the two chambers was continuously monitored by ionization chamber detectors(RD-200, FRD1600, FTLab, Korea) and, in the 2nd chamber, the radon concentration increase of air filtrated by each filter was inter-compared. HEPA filters and two honeycomb type filters were evaluated. Results of HEPA filter, GAC 1 and GAC 2 were 1142 Bq, 7016 Bq and 12053 Bq, respectively. HEPA filter showed a significantly lower capacity for radon removal than the GAC filters. Also, the GAC 2 filter showed a more than 70 % better result compared to GAC 1 due to the difference in filter materials. Therefore, this system can be used to evaluate the radon removal ability of air cleaner filters, by filter type and filter material.
        4,000원
        26.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The main purpose of this paper was to analyze the removal characteristics of gas/particulate phase pollutants for the present system. Experimentally, we performed to estimate the pressure drop and air pollution removal efficiency with physical variables such as stage number, tube velocity, tube diameter, water spray (NH4OH), and so on. It was concluded that the pressure drop was shown below 111 mmH2O lower than that of the existing scrubber (centrifugal spray chamber, over 200 mmAq) at inlet velocity 3.46 m/s and 5 stage. The particular removal efficiency of this system was to be significantly higher at 99.8% in comparison with that of the existing scrubber for 5 stage, inlet velocity 3.46 m/s and NH4OH (aq) 300 mL/min. It was estimated that the removal efficiencies of SO2 and NO2 were 80% and 70% at system inlet velocity 2.07 m/s and NH4OH (aq) 300 mL/min respectively. Additionally, the present collection system was to be considered as an effective compact system for simultaneous removal of air pollutants (gas/particulate) due to much higher removal efficiency and appropriate pressure drop without a demister.
        4,000원
        28.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Deseeded jujubes are commonly consumed as snacks. This study was conducted to develop a seed-removing machine for jujubes that relieves hard work in manual seed removal. The seed-removing machine consists of a jujube supplying unit, a punching unit, and a discharging unit. To test the performance of the machine, shape characteristics, seed removing rate, sarcocarp cracking rate, and flesh hardness were analyzed throughout the jujube storage period. The machine showed good seed removing and sarcocarp cracking rates at room temperature and cold temperature storage on days 2, 15, and 50. Seed removing rates were 80% at day 15 and 96% at day 50. The sarcocarp cracking rates were 33% for day 15 and 30% for day 50. Hardness started to decrease from day 8 to day 70 at both room temperature and cold temperature storage. The working capacity of the machine was 900 fruits/h. The results showed that the jujube seed removing machine is useful for reducing the labor requirements of postharvest jujube processing.
        4,000원
        29.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The main object of this study is to investigate the collection characteristics of an electro-static multi-staged impaction system, experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as the inlet velocity, stage number, applied voltage and shape of discharge electrode, etc. In results, the pressure drop is shown below 148 mmH2O lower than that of the conventional bag filter at inlet velocity 3.46 m/s and 5 stage. For 5 stage , the collection efficiencies are to be 97.4, 99.0% with the applied voltage 0 kV at the inlet velocity 2.07, 3.46 m/s, while 98.4, 99.9% with 40 kV of a sharp edge discharge electrode. Additionally, the present system is to be considered as an effective compact system for a removal of particulate pollutants from marine diesel engines due to much higher collection efficiency and appropriate pressure drop.
        4,000원
        30.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to develop a scrubber wastewater cleaning system to improve the efficiency of odor reduction. We evaluated the changes in scrubber wastewater quality and odor reduction efficiencies before and after applying the pilot system. We determined that it was possible to extend the replacement cycle by two times or more considering the turbidity change and organic removal efficiency. Butyraldehyde, a major odor-causing substances in the exhaust gas of the target facility, is soluble in water. As a result, the odor reduction efficiency was improved by removing the butyraldehyde in the scrubber wastewater. Economically, it is possible to save about 12 million won per year. Thus, it is necessary to keep scrubber wastewater clean in order to improve the deodorization efficiency and reduce the cost of disposal.
        4,000원
        31.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, We evaluated the efficiency of the smart ventilation system being developed at the test-bed(KCL). Smart ventilation system improve the indoor air quality by absorbing carbon dioxide. It is reducing the infusion of outside air can be reduced to minimum energy consumption. To evaluate the energy savings and carbon dioxide removal efficiency. It was more effective when working with air conditioning and ventilation system at the same time.
        4,000원
        32.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: This study aims to establish the priority of introducing anti-icing spray system for regions of the National Highways in South Korea. Using this study, a logical plan for instituting such an anti-icing spray system can be established for the National Highways METHODS : The Analytical Hierarchy Process (AHP) was employed to prioritize the implementation of an anti-icing spray system on Korean highways. For this purpose, an existing scoring table developed by the Ministry of Land, Infrastructure Transport Affair was slightly modified in order to reflect recent trends in winter maintenance. A survey was conducted to gather the preferences regarding the developed hierarchy of road experts and agencies. Finally, the final score was produced by integrating the scoring results with estimated weights for each evaluation criterion. RESULTS: In general, Honam and the metropolitan areas have relatively high priority while other areas such as Chungcheong, Young Nam, and Gang Won appear to be uniform in importance in terms of establishing an anti-icing spray system. This result may indicate that historical weather data and traffic volumes are significant factors in deciding in winter maintenance polices CONCLUSIONS : In this study, useful insights are suggested regarding winter maintenance by simultaneously performing rapid snow removal and proactive treatment. Issues of resource allocation may be potential research items in the field transportation engineering.
        4,000원
        33.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        배타적 경제수역에 존재하는 난파물은 선박의 항행안전 및 해양환경에 위협 이 되지만 난파물 제거에 관한 국제법규가 존재하지 않는다. 이러한 상황을 해 결하기 위해 2007년 난파물 제거에 관한 나이로비 국제협약이 채택되었고 2015 년 4월 발효될 예정이다. 동 협약은 배타적 경제수역에 존재하는 난파물을 신 속하고 효율적으로 제거하고 이에 따른 비용의 지급을 보장하는 통일된 국제규 칙 및 절차를 제공하기 위한 규정을 포함하고 있다. 우리나라도 난파물로 인해 어려움을 겪었다는 점과 우리나라 국적선이 동 협약의 국제적 발효로 인한 선 박 운항상 어려움이 발생하지 않도록 협약의 비준 및 국내 이행을 위한 국내법의 정비가 필요한 상황이다. 이에 본 논문에서 동 협약의 국내법 수용을 위한 법률 정비 방안을 제시하였다.
        6,900원
        34.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The main object of this study is to investigate the collection characteristics of wet-type rotating porous disk system experimentally. The experiment is carried out to analyze the pressure drop and collection efficiency for the present system with the experimental parameters such as system inlet velocity, stage number, tube diameter, inlet concentration, etc. In results, for the present system, at 5 stage and υin=1.8 m/s, the pressure drop becomes significantly lower as 64 mmH2O in comparison with that of the conventional wet type scrubber (Venturi scrubber, over 250 mmH2O). The collection efficiencies increase with higher inlet velocity showing 92, 95.7, 98.4%, while SO2 removal efficiencies decrease with increment of inlet velocity as 80, 65, 50% at υin=1.08, 1.44, 1.8 m/s and tube diameter Dt=10 mm, respectively. The present system is to be considered as an effective compact system for a simultaneous removal of particle/gas phase pollutants from marine diesel engines.
        4,000원
        35.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2010년 전국적으로 소, 돼지와 같은 동물에 구제역이 발병하였고, 이에 전국에 약 4,800여개의 매몰지가 긴급 조성되고 약 300만 마리의 동물들을 살처분 되었다. 이렇게 조성된 매몰지 내부에서는 가축사체가 부패하는 과정에서 황화수소, 메르캅탄류, 아민류 와 같은 악취물질이 생성되고, 매몰지 이설과정에서 대기 중으로 확산된다. 본 연구에서 는 가축 매몰지 이설과정 중에 발생하는 황 계열 물질을 저온 플라즈마 시스템을 적용하 여 저감하고자 하였다. 특히 플라즈마 시스템에서 상대습도에 따른 황화수소와 다이메틸 다이설파이드(DMDS) 제거량 변화를 실험적으로 확인하였다. 동일한 유입 조건에서 상대 습도가 증가함에 따라 황화수소와 DMDS의 제거율은 증가하였고, 이는 상대습도가 높아 지면서 발생하는 오존량이 증가하였기 때문이었다. 황화수소와 DMDS의 오존 반응식을 깁스 자유에너지로 비교해보면 DMDS의 오존 산화가 더 높은 에너지를 방출하는 것으로 나타나며, 이에 따라 황화수소보다는 DMDS가 먼저 오존에 의해 산화되며 남은 황화수 소는 촉매 층에서 추가 반응하는 것으로 판단된다.
        4,000원
        36.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        도시지역 합류식 하수배제 설비인 우수받이 및 하수관거, 정화조 등에는 유기성 고형 물이 퇴적되기 쉬우며, 유기성 퇴적물이 부패되는 과정에서 고농도의 황계열 악취물질이 발생한다. 본 연구에서는 전기산화방식을 이용하여 유기성 퇴적물 내에 용존된 악취물질 및 전구물질을 저감시켜, 하수관거에서 기상으로 배출되는 악취 문제를 해결하고자 하였다. 실험실 규모의 밀폐된 회분식 반응기에 하수슬러지(COD 기준 8,000 ~ 28,000 mg·L-1)를 투입하고, 발생되는 악취물질 농도와 악취발생특성을 조사하였다. 여기에 전기산화시스템 을 적용하여 황계열 악취물질과 전체 유기물의 산화 및 분해실험을 진행하였다. 전기산 화 실험을 진행한 결과, 밀폐된 반응기의 기상에서 450 ppm의 고농도로 발생한 황화수 소가 반응 30분 이내에 검출한계 이하까지 제거되었으며, 메틸머켑탄과 디메틸설파이드 는 85% 이상 제거되었다. 투입된 전기에너지당 황계열 악취물질의 제거율은 최대 0.33 mg-S·kJ-1로 나타났다. 또한 1시간의 반응기간 동안 회분식 반응기 내에서 황계열 악취물 질 뿐만 아니라 고농도 퇴적물에 함유된 전체 유기물 농도가 56% 감소하여, 전기산화시 스템이 악취를 유발하는 유기성 전구물질을 동시에 저감하는 효과를 나타내었다. 결과적 으로 최소한의 전기에너지를 이용하여 하수관거 퇴적 유기물에 의한 악취문제를 해결할 수 있을 것으로 기대된다
        4,000원
        37.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Project owner, asbestos removal specialist, experts on asbestos removal work, as counter parts to be defined in the study to make out research goals have been asked with questionnaire survey and replied with 65, 275, 32 cases, respectively. And additionally, direct interview 73 sheets have been collected to find out current status of required engineers and equipments assigned and provided to the field, from them, three(3) concerned parties. Questionnaire subjects are composed of common items, reasonable unit cost, need of separate contract-awarding system, status of performing standard contract, status of providing legal engineers and equipments. Concentrated review of two~three questions by subject has been made to find out and compare idea results between three(3) concerned parties. First, legal and practical work status survey have been made to determine reasonability of introducing separate contract-awarding system, as a part of ensuring reasonable unit work cost. And then, two different status have been compared and there is introduction possibility of separate contract-awarding system, it is found out. The possibility of separate contract also has been confirmed by comparison of domestic legal grounds. Justificating grounds to introduce separate contract-awarding system have been shown. Standard contract status between asbestos removal specialists has been compared using two cases of providing removal work contract and receiving it. It is shown that case of 50 percent or less contains 38.5% when they receive contract, but only 10 percent reduction of original contract amount has been made when they provide it. It means that asbestos removal specialists do not keep occupational safety and health regulations.
        4,000원
        38.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        국내산 담수 이매패 펄조개를 이용하여 부영양 저수지 의 표층수를 실험실로 유입∙처리하고 처리수는 다시 저 수지로 환원하는 이른바 ‘흐름형 유기물 제어’ (CROM: continuous removal of organic matters) 기술을 개발하고 하천에서 채취한 모래퇴적물의 첨가가 유기물 제어와 수질에 어떠한 영향을 주는지 조사하였다. CROM은 크게 저류조, 조정조, 처리조, 분석조 등으로 이루어졌으며, 실험은 처리조에 현장수, 현장수+모래, 현장수+패류, 현장수+모래+패류 등을 각각 구성하여 유입속도는 18~25 Lh-1, 패류밀도는 486.1 indiv. m-2, 수온은 15~22􀆆C 범위에서 13일간 실시하였다. 유기물 및 수질 변화를 확인하기 위하여 매일 동일한 시간에 수온, pH, DO, 전도도, 탁도, 염분도, 엽록소 a, 부유물질, TN, TP, NO2, NO3, NH3, PO4 등을 측정하거나 채수하여 곧바로 분석하였다. 연구결과, 미처리수의 반송이 패류의 유기물 제어에 큰 영향을 미치지 않았으며 퇴적물의 첨가에 상관없이 실험기간 동안 80% 이상 유기물(부유물질 및 Chl-a)을 감소시켰으나 높은 농도의 암모니아와 인산 등을 배출하였다. 결국 한국산 이매패 펄조개를 이용한 CROM 운영효과는 매우 뚜렷하였으나 장기간 운영시 유기물 제어능 및 패류 생존율에 미치는 다른 요인들-수온, 미생물, 세정주기 등의 변화가 예상되며, 처리수에 대한 처리 및 활용에 대한 다각적인 연구가 뒤따라야 할 것으로 사료되었다.
        4,200원
        39.
        2006.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        In recent models of semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants such as NH3, SOx and organic gases introduced from outdoor air into clean room. Meanwhile, there is a large quantity of exhaust air produced from clean room. It is desirable to recover heat from exhaust air and use it to reheat outdoor air. In the present study, an experiment was conducted to investigate heat recovery, particle collection, and gas removal in a heat recovery type air washer system for semiconductor manufacturing clean rooms.
        4,000원
        40.
        2005.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        A ventilation system comprising a dielectric barrier discharger and UV‐TiO2 photocatalyst filters was designed and tested for simultaneous removal of gaseous and particulate contaminants in a test chamber. The DBD was used as the 1st stage of ESP for particle charging and gas decomposition. Charged particles were collected in the 2nd stage of ESP by an applied DC electric field. The UV‐TiO2 photocatalyst filters were used for decomposing gaseous species including O3 which was inherently produced by the DBD. Particle removal efficiencies based on mass and number were approximately 83.0% and 88.8%, respectively, after the ventilation system was operating for 5 hours. HCHO removal efficiency was approximately 100% for 1∼5ppm of upstream concentration condition. TVOC removal efficiency was 99.0% and 99.6% for 1 ppm and 5 ppm of upstream concentration conditions, respectively.
        4,200원
        1 2 3