검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 24

        1.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study improved the work efficiency by supplementing the shortcomings of the manual process by developing a double tube feeding device, and the following results were obtained by conducting the production capacity, production length, and defect rate tests. Developed a double tube production system to enable the simultaneous production of two tubes, increasing the production volume by about 1.5 times. The product length has been improved from semi-automatic to automated, and the production capacity has been improved from 16 to 25 pieces per hour (based on 15m). Developed a double-tube input straight line automatic adjustment feeder, which resulted in reducing the defect rate to less than 1%.
        4,000원
        2.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In general, small and medium-sized computer rooms do not have access floors for reasons of increased floor height and increased construction cost. Therefore, the air conditioning method used here applies the method of directly blowing the cold air of the air conditioner into the computer room. In this case, the hot/cold air is not separated, and as the hot air is recirculated, it is re-introduced to the front of the server rack, resulting in a problem that the server cooling efficiency is decreased. In addition, in such a computer room structure, it is difficult to configure and install a containment system. In this study, we tried to understand the problem of the formation airflow in the case of using the existing air conditioning method, and to find a method of configuring the air conditioning environment to improve the cooling efficiency. The purpose of this study was to understand the airflow/temperature distribution in the computer room using the CFD simulation method. In addition, the thermal characteristics of various air-conditioning environments such as the location of the CRAC cold air discharge location, the layout between server rack and CRAC and the containment were reviewed.
        4,000원
        3.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To ensure the safety and functionality of a railroad bridge, maintaining the integrity of the bridge via continuous structural health monitoring is important. However, most structural integrity monitoring methods proposed to date are based on modal responses which require the extracting process and have limited availability. In this paper, the applicability of the existing damage identification method based on free-vibration reponses to time-domain deflection shapes due to moving train load is investigated. Since the proposed method directly utilizes the time-domain responses of the structure due to the moving vehicles, the extracting process for modal responses can be avoided, and the applicability of structural health evaluation can be enhanced. The feasibility of the presented method is verified via a numerical example of a simple plate girder bridge.
        4,000원
        4.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This experiment evaluated the efficiency of mechanical ventilation, one of the measures to reduce indoor radon concentration in residential spaces. In the most popular ventilation rates of the air conditioning system, the most efficient air conditioning system was confirmed by checking the time when the radon concentration reached the lowest level, the radon reduction rate, and the radon concentration that could be lowered as much as possible. The results showed a reduction rate of up to 80% or more as a result of conducting the experiment by blocking the inflow of outside air. It was confirmed that the time to reach the lowest concentration after starting the mechanical ventilation was about 6 hours to a maximum of 7 hours. Therefore, this study verified that indoor radon concentrations can be efficiently reduced by using a mechanical ventilation system.
        4,000원
        5.
        2018.11 구독 인증기관 무료, 개인회원 유료
        To ensure the safety and functionality of a railroad bridge, maintaining the integrity of the bridge via continuous structural health monitoring is important. However, most structural integrity monitoring methods proposed to date are based on modal responses which require the extracting process and have limited availability. In this paper, the applicability of the existing damage identification method based on free-vibration reponses to time-domain deflection shapes due to moving train load is investigated. Since the proposed method directly utilizes the time-domain responses of the structure due to the moving vehicles, the extracting process for modal responses can be avoided, and the applicability of structural health evaluation can be enhanced. The feasibility of the presented method is verified via a numerical example of a simple plate girder bridge.
        3,000원
        6.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 냉동공조용 열교환기 내 스케일 형성으로 열전달 과정에서 열저항으로 작용하여 냉동공조시스템의 냉각성능이 떨어져 이를 해결하기 위해 전기분해 원리를 이용하여 배관 내 스케일을 자동 제거하는 시스템을 개발하여 그 성능을 실험을 통해 확인하고자 한다. 이전까지는 배관 내 스케일을 2∼3 년에 한번씩 브러시나 분사 노즐에 의해 기계적으로 배관 내를 청소를 하거나 화학약품을 이용하여 세관하였다. 이러한 세관은 시간이 경과하면 또 관이 오염되어 전열성능이 떨어지고 냉각장치의 운전을 정지하여 반복해야하는 여러 가지 문제점을 안고 있었다. 따라서 시스템의 정지없이 전기분해 원리를 이용하여 만들어진 처리수를 순환시킴으로서 스케일의 원인물질은 Ca, Mg, SiO2를 고형물 형태로 석출시켜 배관계 외부로 배출시킴으로서 배관내 스케일 발생을 차단하고 기 형성된 스케일을 제거하여 배관의 전열 성능을 유지하고자 하는 것이다. 실험한 결과, 새 배관의 열전달율을 100으로 기준할 경우, 스케일이 형성된 배관의 열전달율은 86.66%이었으며, 스케일이 형성된 배관을 1개월 동안 처리수를 가동했을 경우 열전달율은 90.5%의 수준까지 회복되었으며, 2개월간 운전한 경우 97.86%의 수준까지, 3개월 운전했을 경우 98.72% 까지 열전달율이 회복되었다. 비교적 짧은 실험기간이지만 배관내 형성된 스케일의 제거효과를 파악하였으며, 전열성능에도 영향을 미치고 있음을 확인하였다.
        4,000원
        7.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the odor-associated bacterial community in automobile HVAC systems. Through a metagenome analysis, it was found that; Massilia (42.426%), Sphingomonas (28.200%), (10.780%), and Methylobacterium (5.756%) were abundant in the HVAC systems. Massilia can cause the biodegradation of polycyclic aromatic hydrocarbons (PAHs) producing odor in automobiles. Sphingomonas produces volatile halogenated compounds or degrades organic pollutants. Rhodococcus is reported to produce sulfur compounds which give off an odor similar to rotting eggs and cabbages. Methylobacterium is one of the most representative bacteria that causes odor in automobile HVAC systems. The evaporator is considered as the appropriate habitat for microorganisms in automobiles because of its high humidity and organic adsorption. Massilia, Sphingomonas, Rhodococcus, Methylobacterium, Bacillus, Staphylococcus, Arthrobacter, Micrococcus, and Pseudomonas, listed in order from most to least present, were isolated as abundant bacteria in the evaporator of the HVAC systems.
        4,000원
        8.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we utilize a Gaussian process to predict the power consumption in the air-conditioning system. As the power consumption in the air-conditioning system takes a form of a time-series and the prediction of the power consumption becomes very important from the perspective of the efficient energy management, it is worth to investigate the time-series model for the prediction of the power consumption. To this end, we apply the Gaussian process to predict the power consumption, in which the Gaussian process provides a prior probability to every possible function and higher probabilities are given to functions that are more likely consistent with the empirical data. We also discuss how to estimate the hyper-parameters, which are parameters in the covariance function of the Gaussian process model. We estimated the hyper-parameters with two different methods (marginal likelihood and leave-one-out cross validation) and obtained a model that pertinently describes the data and the results are more or less independent of the estimation method of hyper-parameters. We validated the prediction results by the error analysis of the mean relative error and the mean absolute error. The mean relative error analysis showed that about 3.4% of the predicted value came from the error, and the mean absolute error analysis confirmed that the error in within the standard deviation of the predicted value. We also adopt the non-parametric Wilcoxon’s sign-rank test to assess the fitness of the proposed model and found that the null hypothesis of uniformity was accepted under the significance level of 5%. These results can be applied to a more elaborate control of the power consumption in the air-conditioning system.
        4,000원
        9.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, by comparing the heating performance when operating the air conditioning system that is installed directly air-cooled(heater) air conditioning central air conditioning system of the ship, with improved performance, through the actual measurement study of thermal environment of the cabin, Ship's air conditioning in the future it is intended to be used as a basic data experience of design and planning.
        4,000원
        10.
        2015.11 구독 인증기관 무료, 개인회원 유료
        In this study, to develop high-efficiency environmental improvement system that can be combined with hot and cold potable water supply to poultry air conditioning for the summer increase heat stress relief and winter feed efficiency through optimal design hwihan The aim of this study was to provide basic data. As a cage the size of the system installed is 100m2 test capacity 20RT district heating and cooling of air-to-water heat pump and the control was composed of electric hot water boilers. First of cage sizes for heating load design, materials, heat pump capacity, air capacity, storage tank, drinking water tank capacity, etc. were determined. The capacity of the heat pump was set to 20RT cage captive birds are erected as vertically and horizontally × height × (13 × 21 × 4.5m). Storage tank 3 tons and capacity of 10 tons potable water tank was designed. In the future, the size of the cage, designed according to the best breeding two numbers are needed.
        4,000원
        11.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 목포해양대학교의 실습선 새누리호를 대상으로 선박의 중앙집중 공조시스템에 공랭식 에어컨을 직접 설치하여 성능을 개선시킨 공기조화시스템으로 운전하였을 경우의 냉방 성능을 비교하고, 선실의 온열환경에 대한 실측조사를 통해서 향후 선박용 공기조화 설계 및 계획에 경험적 기초참고자료로 활용하고자 하는 것이다. 연구결과 동일한 외기조건에서 기존의 중앙집중방식 공조시스템과 개선된 공조시스템으로 운전하였을 경우, 모든 선실의 온도는 24~28 ℃, 습도는 55~75 %로 쾌적한 조건임을 알 수 있었고, 발전기 부하를 측정결과 공기조화시스템의 성능개선에 따라 평균 부하 48 KW, 전부하시 부하율 약 8 %정도 감소하여 1일 연료소모량 FOC는 하루 평균 222[L/day]의 기름이 절약됨을 알 수 있었다. 또한 학생 선실(Cadet No. 21)은 기관실의 전열로 인해서 온도가 높게 나타났는데, 이것은 공기조화 설계 시 취출구 개수 및 전열부하를 고려하지 못한 결과로 판단된다.
        4,000원
        12.
        2014.06 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 선박의 중앙집중 공조시스템에 공랭식 에어컨(전기히터 내장형)을 직접 설치하여 성능을 개선시킨 공기조화시스템으로 운전하였을 경우의 난방 성능을 비교하고, 선실의 온열환경에 대한 실측조사를 통해서 향후 선박용 공기조화 설계 및 계획에 경험적 기초참고자료로 활용하고자 하는 것이다. 연구결과 동일한 외기조건에서 기존의 중앙집중 방식 공조시스템과 개선된 공조시스템으로 운전하였을 경우..
        3,000원
        13.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 선박의 중앙집중 공조시스템에 공랭식 에어컨을 직접 설치하여 열원의 성능개선과 거주 구역별 독립 냉 난방이 가능한 개별분산 공조시스템을 하고자 하는 것이다. 연구 결과 기존의 중앙집중방식 공조시스템에 비해 열원 제어와 열효율상의 문제점을 보완함과 동시에 장치의 효율을 향상시킴을 확인하였다. 또한 동일한 조건에서 장치의 냉동능력과 성능계수는 평균 약 3 %, 23~26 % 정도 높게 나타났으며, Chilled Water Plants의 압축기 소비동력은 약 12 % 정도 낮게 나타났고, 동일한 조건에서 난방 시 소비동력은 약 33.5 % 낮게 나타났다. 따라서 공랭식 에어컨을 이용한 개별분산 공조시스템이 열원 제어뿐만 아니라 장치의 성능향상과 거주구역별 쾌적한 온 습도 환경 조성에 크게 기여하는 결과를 얻을 수 있었다.
        4,000원
        15.
        2009.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        HFC-134a is currently used as a refrigerant in automotive air conditioning system replacing the ozone depleting CFC-12 refrigerant. This paper was experimentally studied on the performance characteristics of an automotive air conditioning system with variations of charging refrigerant and compressor speed. An air conditioning system was composed of laminated type evaporator, parallel flow type condenser, vane rotary type compressor, externally equalized thermostatic expansion valve and receiver drier with specifications of Hyundai Sonata Ⅱ vehicle. And the automatic measuring system of air conditioner used KTE-1000BA developed by a KT ENG Co., Ltd.. of Korea. The optimum conditions which were tested as available parameters for better performance are indicated charging refrigerant 800 g and compressor speed 1700 rpm.
        4,000원
        1 2