In the semiconductor manufacturing clean room, contamination that directly affects process yield is managed through the operation of a monitoring system that measures molecular contamination in the air. In this study, I presented the component inspection method, test conditions, and judgment criteria through the life test of the solenoid valve that will be applied to the sampling module of the AMC Monitoring System.
The Calorifier is a device that supplies hot water to the crew for showering and cooking. In particular, problems such as hot water not coming out when a trainee and a crew member take a shower at the same time may occur due to a malfunction of the temperature control valve that controls the temperature. In particular, when the hot water usage time is almost constant, such as a training ship, a high calorific value is required. When there is no dissatisfaction with the use of hot water, satisfaction with the educational environment is improved. Therefore, in this study, a solenoid temperature control valve is applied to increase satisfaction with hot water use, and a mechanical time switch is applied to the hot water circulating water pump to save energy.
In this paper, we investigate the relationship between control system of Bosch system and that of Delphi system by measuring the high and low voltage waveform, current waveform and fuel injection quantity of D-2 and R- engines. Waveform measurements are used the PICO scope and the CDS tester. The injectors of D-2 and R-engines were tested under no load condition using injector with normal fuel injection quantity, injector with small fuel injection quantity and injector with many fuel injection quantity. The relation between current energy and fuel injection quantity shows that the injector variation rate of D2-engine is much larger than that of R-engine. The injector current energy of the D2-engine was more linear than that of the R-engine, therefore making the system more stable. Although the control system of the D2-engine is a more stable system only in terms of the durability of the internal parts of the injector, the injector of the R-engine has a good response because the current value is large.
In this paper, 'Pico scope' was used to measure and analyze high voltage waveforms of 'Grade injector' and 'IQA injector' due to defective solenoid injector of CRDI diesel engine, and the following conclusions were obtained. In the case of the injector of 'Grade Injector' and 'IQA Injector', there was no change in the injection timing of the injector while the injector was installed. However, by controlling the operation time, It is judged that the injector control is insufficiently controlled when the number of revolutions of the engine is increased to 2000 rpm and 3000 rpm in the idling state in the idling state because the injector failure is precisely controlled in the idling state, When determining the fault injector, the waveform of the 'Grade injector' and 'IQA injector' can be detected by waveform analysis by comparing the injection control time by measuring the high voltage waveform of the injector control in idle idling state. Can be easily diagnosed and maintained. I hope this study will be handed to the mechanics to make diagnosis of CRDI injector convenient.
This paper investigates the relationship between the waveform area and fuel injection quantity. It is on developing on analysis method of waveform the effect of waveform area on fuel injection quantity of CRDI Diesel engine. The experimental methods using Pico oscilloscope and fuel injection tester are employed to measure current and voltage waveform and fuel injection quantity of solenoid injector. The one normal and two abnormal solenoid injectors are used. The experiment is carried out during no-load condition. A summary of the important results are as follows. 1) The area of the voltage and current waveform of the abnormal injector becomes larger than the that of normal injector, and the area of the current and voltage waveform is inversely proportional to the fuel injection quantity. 2) The area of the current waveform can be obtained more accurate results than that of voltage waveform. 3) It is possible to infer the fuel injection quantity by measuring the current waveform and calculating the area.
This paper is on developing the waveform analysis method in driving control of solenoid injector of CRDI diesel engine. The experimental methods using Pico oscilloscope and scan tool is employed to measure current and voltage waveform of solenoid injector. The solenoid injector are used 1 normal and 2 abnormal injectors. The experiment is carried out during no-load condition. The magnitude of pressure drop is largest main duration, pre and pilot duration in the order named in case of normal injector, whereas was largest pilot duration, pre and main duration in the order named in case of abnormal injectors.
This paper investigates the waveform analysis of voltage and current waveform from CRDI engine. It is on developing on analysis method of waveform CRDI Diesel engine. The experimental methods using Pico oscilloscope are employed to measure current and voltage waveform of solenoid injector from CRDI engine. The one normal and two abnormal solenoid injectors are used. The experiment is carried out during no-load condition. A summary of the important results are as follows.
1) The area of the voltage and current waveform of the abnormal injector becomes larger than the that of normal injector.
2) The area of the current waveform can be obtained more accurate results than that of voltage waveform.
This study investigates the development of an automatic lightening buoy that can indicate an aquaculture cage at night or in rough weather. The energy for the light is generated by the linear motion of a magnet along with a coil inside the buoy as the waves cause the buoy to oscillate up and down. The principle of the magnet motion is different between the magnet and body of the buoy because the movement of the latter is dependent on the surface wave, while the former is affected by the damper. To obtain a quantitative performance of the buoy, the voltage as well as up and down motion produced by several waves were measured in the wave tank. A shorter wave period, i.e., faster motion, of the magnet produced a brighter light. It is expected that this study can aid in deciding the optimum design of a buoy capable of producing a bright light at any aquaculture site affected by sea or fresh water waves.
In this paper, we developed a power amplifier system for driving a solenoid coil. The developed system consists of three units; control unit, drive unit and coil. The control unit generates a drive signal of sinusoidal wave type, monitors an operating status of the drive unit and vibration characteristics of the coil. The drive unit drives a solenoid coil in response to command from the control unit. The coil was fabricated with the size of diameter in 1.5 cm and length in 1.7 cm using electric copper wire. 4 types of drive unit were tested with thermal and vibration characteristics of the coil using temperature sensor and 3-axis accelerometer, respectively. From the result, the developed system has many advantages with respect to simple control algorithm, small size, and operates stably up to 68 watts driving condition.
In this paper, the vibrational characteristic of electronic solenoid structure for vehicle is analyzed by using ADAMS as commercial multi-body dynamics analysis program. This study model is made with CATIA V5R18 as 3D computer-aided design program and analyzed with rigid body mode in ADAMS. To fulfill the vibration analysis, the result value of solenoid structure is suggested.
This paper presents a six sigma application case study for an automobile PCSV manufacturing process using rolled throughput yield improvement activity. Hidden factor and first yield concept is introduced and DMAIC procedure is implemented to maximize the first pass yield. The result of the six sigma project amounts to the reduction of failure cost of 0.1 billion won per year in the PCSV manufacturing process. This paper can benefit six sigma practitioners in some ways.
Generally, the three position solenoid valve has veen used for the hydraulic steering gear on account of it’s low cost, simplicity in device, etc. But, there is some off-set because of dead-zone which exists in on-off valves. In this paper, we proposed a combined controller which was added an integral controller to an only on-off one in hydraulic steering gear control system used low speed three position solenoid valve. Experimental results show that the off-set is removed, and the number of valve switching is reduced considerable. The validity of proposed method comparing with an only on-off control was proved by the response experiments.