        검색결과 56

        2.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to explore the appropriate water pressure control of water supply pipeline to reduce water losses of water supply network in Jinan-gun. The current water pressure status of each 5 blocks and the impact of optimized water pressure on improving revenue water rate were investigated. In order to obtain the flow rate and water pressure data of each small block, a smart hub is set in the pressure reducing valve chamber at the inlet of the small block, and a smart water pressure meter is installed in the fire hydrant and the faucet of the customer. For the pressure reducing valves installed for water pressure management system of each block, the diameter calculation standard and type of the pressure reducing valve are determined, and the application reasons are put forward. The analysis results of water pressure management for each small block in Jinan-gun show that the pressure control equipment and water pressure management need to be improved in four small blocks. The water flow rate in Jinan-eup and Sangjeon-myeon increases from 57.2% to 87.6% when the water pressure control is completed.
        4,000원
        3.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to evaluate the filtration performance according to the feed temperature composed of NaCl and the operating pressure of the brackish water reverse osmosis (BWRO) process. The temperature is known that decides the filtration performance of reverse osmosis (RO). It is noted that temperature increase activates the permeate of salts due to augment of diffusivity and mass transfer. Filtration of the lab-scale RO system was performed with constant pressure and the constant flow was simulated. The salt rejection measured by the concentration of the feed and permeate was compared with water permeability and salt permeability in the conditions containing various temperatures (5, 10, 15, 20, 25, and 30℃) and pressures (10, 12, 15, and 18 bar). An increase in feed temperature from 5 °C to 30 °C caused a 4.65% decrease in salt rejection in CSM, due to an increase in salt permeability (4.06 times) rather than an increase in water permeability (2.62 times). Specific energy consumption (SEC) was calculated by using an electricity meter set in the RO system. It was expected that the SEC by the increases in temperature and pressure decreased due to the viscosity decline of the feed and the permeate flux augment, respectively. The SEC decreased by 63.4% in CSM and by 54.3% in Nittodenko when the feed temperature increased from 5 °C to 30 °C. It discussed how to operate the optimal RO process through the effect of temperature and operating pressure and the comparison of SEC.
        4,000원
        4.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 GFRP관을 상수도관으로 사용하기 위해 테스트베드를 설치하여 지중매설된 관의 구조적 거동에 미치는 영향을 조사하였다. 또한, GFRP관의 역학적 성질을 조사하고 관 강성을 추정하였다. KS규격에서 제시하고 있는 허용드로우와 고압력(사용압력의 1.5∼2.0배), 트럭하중을 적용시켜 관 내부와 외부의 복합하중이 작용할 경우 관 내압의 변화와 관의 거동을 확인하였다. 그 결과, 상수관으로 GFRP관을 장기 사용하여도 충분한 내압을 가지고 있음을 확인하였다.
        4,000원
        5.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High-pressure membrane system like nanofiltration(NF) and reverse osmosis(RO) was investigated as a part of water treatment processes to produce high quality potable water with low organic matter concentration through membrane module tests and design simulation. River water and sand filtration permeate in Busan D water treatment plant were selected as feed water, and NE4040-90 and RE4040-Fen(Toray Chemical Korea) were used as NF and RO membranes, respectively. Total organic carbon(TOC) concentrations of NF and RO permeates were mostly below 0.5 mg/l and the average TOC removal rates of NF and RO membranes were 93.99% and 94.28%, respectively, which means NF used in this study is competitive with RO in terms of organic matter removal ability. Different from ions rejection tendency, the TOC removal rate increases at higher recovery rates, which is because the portion of higher molecular weight materials in the concentrated raw water with increasing recovery rate increases. Discharge of NF/RO concentrates to rivers may not be acceptable because the increased TDS concentration of the concentrates can harm the river eco-system. Thus, the idea of using NF/RO concentrate as the raw water for industrial water production was introduced. The design simulation results with feed water and membranes used in this work reveal that the raw water guideline can be satisfied if the recovery rate of NF/RO system is designed below 80%.
        4,000원
        7.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to global climate change, mega-droughts have occurred frequently. Since long-term droughts make it difficult to secure the water resources, water supply needs to be restricted in a reasonable manner. In the event of limited water supply, the waterworks need to develop a restricted water supply strategy. This study showed that analyzing daily water supply could be used to respond to the first stage of a drought. According to an analysis of Korea's major water authorities, there was about 7~21% of room for daily minimum water supply in case of a drought. Restricting the water supply by lowering pressure is a good strategy for local water authorities with high water leakage rate since leakage is inversely dependent with pressure. For this method, it is necessary to quantify water deficiency and pressure at each node using a simulation. Since DDA-based software is not possible to predict changes in demand at nodes with pressure reduction, WaterGEMS, a PDA software, was used to quantitatively predict water shortages and pressures at each node. Locations where water is deficient need to install booster pumps or to be dispatched with water tank truck and bottled water. Without these support, lowering pressure could not be an option for water works. This paper suggests a method for waterworks to plan a drought by lowering pressure to restrict water supply using daily water supply analysis and PDA based simulation.
        4,000원
        8.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study’s results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building’s stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system’s internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.
        4,300원
        9.
        2019.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out to produce stable evening primrose oil in water emulsion by using various emulsifier with HLB (8.6, 12, 16.7), concentration (0-45%) and emulsification methods such as high-speed emulsification (7,000 rpm, 2 min) and high-pressure homogenization (10,000 psi, 1 cycle). And then properties of evening primrose oil in water emulsion was evaluated with keeping at room temperature and 40oC during 28 days. Lower HLB 8.6 and high viscosity emulsifier added emulsions were not appropriate for high-pressure homogenization and were separated in a day. The optimum emulsification condition was HLB 12 and high-pressure homogenization (10,000 psi, 1 cycle) for evening primrose oil in water emulsion. These emulsions produced by optimum condition were not separated with the aqueous phase and the oil phase and they were nano-sized around 200 nm, higher zeta-potential (±mV), mono-polydispersed (<0.3), and less oxidized (<0.4) during 28 days.
        4,000원
        11.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        At a two phase flow, according to gas and liquid phase flow rates, various flow regimes are developed such as bubbly, slug/plug, churn, annular, droplet flow and so on. At a two phase flow in small scaled channels, among various flow regimes, the intermittent flows such as bubbly, slug/plug flow are developed in the broad regions of two phase flow pattern map. In particular, the flow regimes are influenced by surface wettability. In a case of slug flow in hydrophobic small scaled channels, gas and liquid phases are perfectively separated by interfaces and contact line. The pressure drop of the two-phase flow is largely generated at moving contact line. Therefore, to well design two-phase flow system with small scales, it is important to estimate the pressure drop at moving contact line. In this study, on the basis of previous research, the pressure drop at moving contact line is experimentally measured for a various fluids (0-40% water-ethanol mixtures). And, the previous correlation to estimate pressure drop at moving contact line is verified by experimental data. In an addition, we discuss interfacial broken phenomena of slug flow in a minichannel. (D=1.555mm).
        4,000원
        12.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To understand the effect of high pressure on nitrogen oxides (NOx) formation in water added methane flames, opposed nonpremixed Water-methane/air (H2O-CH4/air) flames are numerically studied with high initial pressure. With GRI 3.0 detailed kinetic mechanism, NOx emissions are predicted for various strain rates. Due to high pressure, the chemical species are distributed in a narrow region, which means the thickness of the flame is thin. This can be clearly seen with high strain rate. Elevated pressure increases maximum temperature of flames which results in increased NOx emission. Even with elevated initial pressure, NOx emissions for H2O added methane flames are significantly decreased compare to pure methane flame. In addition, increased strain rate is also significant factor for decreasing NOx emission. With detailed rate of production analysis, in case of high pressure, it is confirmed that NO2 pathway is the most dominant reaction pathway than any other pathways.
        4,000원
        13.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Graphene oxide (GO) laminate is a new promising material for water purification system, which has extraordinary permeability only for water molecule. It consists of numerous nano-channels, in which water molecules could be nano-confined, resulting in slip of the molecules for very fast transportation speed. In this study, water penetration rate via different thickness of GO membrane according to driven pressures are measured experimentally, so that speed of water molecules and permeability are evaluated. Generally, water penetration rate via a membrane with macroscopic-sized channel increases linearly with pressure difference between up and bottom side of the membrane, but that via GO membrane approaches asymptotic value (i.e. saturation) as like a log function. Moreover, the permeability of GO membrane was observed in inverse proportion to its thickness. Based on the experimental observations, a correlation for volume flux via GO membrane was suggested with respect to its thickness and external pressure difference.
        4,000원
        15.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Direct spring loaded pressure relief valve(DSLPRV) is a safety valve to relax surge pressure of the pipeline system. DSLPRV is one of widely used safety valves for its simplicity and efficiency. However, instability of the DSLPRV can caused by various reasons such as insufficient valve volume, natural vibration of the spring, etc. In order to improve reliability of DSLPRV, proper selection of design factors of DSLPRV is important. In this study, methodology for selecting design factors for DSLPRV was proposed. Dynamics of the DSLPRV disk was integrated into conventional 1D surge pressure analysis. Multi-objective genetic algorithm was also used to search optimum design factors for DSLPRV.
        4,000원
        17.
        2017.05 구독 인증기관·개인회원 무료
        The straight nanopores in cellulose acetate (CA) polymers for battery gel separators were generated by utilizing both Ni(NO3)2·6H2O and water pressure. When polymer film was exposed to water pressure, the continuous nanopores were generated after complexing with Ni(NO3)2·6H2O. These results could be explained by that polymer chains were weakened because of the plasticization effect of the Ni(NO3)2·6H2O incorporated into the CA. The well controlled CA membrane after water pressure treatment enabled fabrication of highly reliable cell by utilizing 2032-type coin cell structure. The resulting cell performance exhibited both the effect of the physical morphology of CA separator and the chemical interaction of electrolyte with CA polymer which facilitates the Li-ion in the cell.
        18.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In general, polyethylene (PE), polyvinyl chloride (PVC), and ductile cast iron pipes are widely used in the water supply pipeline system. However, they have some disadvantages such as reduced durability due to material degradation, defects in connections, breakage of pipelines, and difficulties in continuous maintenance. To mitigate such problems, recently, research on durable and outstanding corrosion resistant glass fiber reinforced polymer plastic (GFRP) pipe is being actively conducted. GFRP is classified into the flexible pipe and when soil pressure and live load act on buried GFRP pipe, the load acting on the pipe is transferred to the surrounding soil. So, it should review the structural behavior and interaction between buried pipe and its surrounding soil because pipe will support the load with the surrounding soil together at the same time. To apply GFRP pipe for the water supply pipeline system, the structural reliability of GFRP water supply pipe buried underground should be investigated by examining the mechanical properties of GFRP pipe as well as the soundness of the pipe under buried state. The field test of buried pipe is conducted and the results are analyzed and discussed.
        4,000원
        19.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Pressure monitoring is expected to be expanded in a water distribution system according to accelerated development of smart water network management technologies caused by appearances of affordable digital infrastructures like computing, storage and bandwidth. However, the placement of pressure sensors has been determined by engineer’s technical decisions since there is no well-defined criteria for deciding a suitable location of pressure sensor. This study presents a placement method of pressure sensors based on the consideration of allowable error in calibrating water network analysis modeling. The proposed method is to find a minimum set of pressure sensors for achieving a reliable management of water transmissions main and increasing the efficiency of their real-time operation. In the case study in Y area’s transmission main, the proposed method shows equally distributed pressure sensors in terms of hydraulics. It is expected that the proposed method can be used to manage transmission mains stably and construct a robust real-time network analysis system as a minimal criteria.
        4,000원
        20.
        2016.04 구독 인증기관·개인회원 무료
        In the water supply pipeline system polyethylene (PE), polyvinyl chloride (PVC), and ductile cast iron pipe are mostly used. However, they have some problems such as reduced durability due to material degradation, defects in connections, the pipelines breakage, and lack of continuous maintenance. Recently, research on durable and outstanding corrosion resistance glass fiber reinforced polymer plastic (GFRP) pipe is being actively conducted. GFRP is classified into the flexible pipe and when soil pressure and live load act on buried GFRP pipe, the load acting on the pipe is transferred to the surrounding soil. So, pipe will support the load with the surrounding soil. In this paper, to apply GFRP pipe for the water supply pipeline system, the structural reliability of GFRP water supply pipe buried underground should be investigated by examining the mechanical properties of GFRP pipe as well as the soundness of the pipe under buried state. The field test of buried pipe is conducted and the results are analyzed and discussed.