간행물

상하수도학회지 KCI 등재 Journal of the Korean Society of Water and Wastewater

권호리스트/논문검색
이 간행물 논문 검색

권호

제38권 제5호 (2024년 10월) 4

1.
2024.10 구독 인증기관 무료, 개인회원 유료
To mitigate carbon emissions, the government aims to transition to renewable energy sources including hydrothermal energy, specifically through wastewater heat recovery. This process involves extracting heat from wastewater or treated water. However, assessments of demand sources for local cooling and heating have predominantly focused on the proximity of nearby facilities, without conducting comprehensive demand analyses or defining explicit supply areas. This study proposes a methodology for prioritizing suitable wastewater treatment plants (WWTPs) for the implementation and expansion of renewable energy. The methodology is based on the gross floor area of potential wastewater heat demand surrounding WWTPs. Initially, potential supply and demand sources were identified based on the capacity of WWTPs and the gross floor area of buildings capable of utilizing wastewater heat. In the Republic of Korea, 330 WWTPs with a capacity of 5,000 m3/day or more have been recognized as demand sources for wastewater heat recovery. The provision of treated wastewater to structures located within a 500 m radius of the WWTPs for heat recovery is considered a feasible option. The potential wastewater heat demand and renewable energy cluster were identified among the surrounding buildings and complexes A total of 13 potential supplies were identified, provided that the gross floor exceeded 60,000 m². Finally, after prioritizing based on WWTPs with these conditions, the underground plant located in the downtown area was ranked as the highest priority. If further analysis of economic feasibility, CO2 reduction, and energy efficiency are conducted, this approach can be expanded and applied within the framework the Water-Energy Nexus. Wastewater heat can be utilized not only as a renewable energy source but also as a means to enhance wastewater reuse through the supply of treated wastewater.
4,300원
2.
2024.10 구독 인증기관 무료, 개인회원 유료
The number, size, and material distribution of microplastics (MPs) sized 20-200 μm in the raw water and water treatment processes were analyzed using FT-IR in three water treatment plants in Jeju Province. The number of MPs was detected at 0.075-0.620 MP/L in raw water and 0.040-0.047 MP/L in filtered water, which is relatively lower than the results of other studies. Regarding the size of the MPs, particles sized 20-50 μm in both the raw water and the treated water accounted for the highest proportion, representing 65.6% and 56.3% of the total, respectively. In terms of MP type distribution, polypropylene (PP) was identified as the main type at 58.7%. In the water purification process, the MPs removal efficiency was the highest at 93.5% in the sedimentation and rapid filtration process, followed by 58.4% in membrane filtration and 40.0% in slow filtration. Continuous monitoring of the distribution of MPs in raw water and water treatment processes is recommended.
4,000원
3.
2024.10 구독 인증기관 무료, 개인회원 유료
A study on the denitrification of reverse osmosis(RO) concentrated wastewater from sewage reuse treatment plant in P city was conducted using waste desulfurization agent obtained from desulfurization process. Sulfur-based autotrophic denitrifying carrier comprises the predetermined amount of waste iron sulfide (FeS, Fe2S3), mine drainage sludge and elemental sulfur showing mesoporisity with 9.9 nm (99 Å) of average pore size. Sulfur denitrifying bacteria and sulfur reducing bacteria were implanted into the pores of sulfur denitrifying carrier. Nitrate was not affected by empty bed contact time (EBCT). It is probably due to larger reducing capacity of the carrier than the concentration of nitrate in RO concentrated wastewater. Total nitrogen (T-N) removal efficiency exhibited about 90% after 4 days. Sulfate ion was surprisingly decreased with sulfur autotropic process due to the reduction of sulfate ion to HS- and S2- by sulfur reducing bacteria. Sulfide and hydrogen sulfide ions were then taken by Fe(OH)3, main component of mine drainage sludge, releasing OH-. Alkalinity was therefore maintained between 7.5 and 8.5 in pH by the released OH-. Also, it had the effect of suppressing the production of H2S, which causes bad odor.
4,300원
4.
2024.10 구독 인증기관 무료, 개인회원 유료
The pressure sensor had been widely used to effectively monitor the flow status of the water distribution system for ensuring the reliable water supply to urban residents for providing the prompt response to potential issues such as burst and leakage. This study aims to present a method for evaluating the performance of pressure sensors in an existing water distribution system using transient data from a field pipeline system. The water distribution system in Y District, D Metropolitan City, was selected for this research. The pressure data was collected using low-accuracy pressure sensors, capturing two types of data: daily data with 1Hz and high-frequency recording data (200 Hz) according to specific transient events. The analysis of these data was grounded in the information theory, introducing entropy as a measure of the information content within the signal. This method makes it possible to evaluate the performance of pressure sensors, including identifying the most sensitive point from daily data and determining the possible errors in data collected from designated pressure sensors.
4,200원