검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 69

        21.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to examine the byproducts formation characteristics at the water treatment plants which applying electrolysis as a disinfection process in Gangwondo, Korea. Total of forty plants located in Gangwon Province, Korea were selected for the study. Correlation between dissolved organic carbon(DOC) and SUVA254 was not clear. Among the species of the disinfection byproducts(DBPs), chlorate and trihalomethanes(THMs) accounted for 76% and 14% of DBPs, respectively. The effect of DOC or SUVA254 on DBPs formation was not clearly demonstrated. The increased amount of THMs due to the raw water bromide content was found primarily in the form of chloroform, and the percent fraction of BDCM(bromodichloromethane) and DBCM(Dibromochloromethnae) was relatively insignificant. When the value of SUVA254 was greater than 2 L/mg·m, the percent fraction of BDCM and DBCM decreased while percent fraction of CF(chloroform) increased.
        4,000원
        22.
        2015.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Although disinfection in drinking water treatment plants provides a safer water supply by inactivating pathogenic microorganisms, harmful disinfection by-products may be formed. In this study, the disinfectant, chlorine, was produced on-site from the electrolysis of salt (NaCl), and the by-products of the disinfection process, bromate and chlorate, were analyzed. The provisional guideline levels for bromate and chlorate in drinking water are 10 μg/L and 700 μg/L, in Korea, respectively. Bromide salt was detected at concentrations ranging from 6.0 ~ 622 mg/kg. Bromate and chlorate were detected at concentrations ranging from non-detect (ND) ~ 45.3mg/L and 40.5 ~ 1,202 mg/L, respectively. When comparing the bromide concentration in the salt to the bromate concentration in the chlorine produced by salt electrolysis, the correlation of bromide to bromate concentration was 0.870 (active chlorine concentration from on-site production: 0.6–0.8%, n=40). The correlation of bromate concentration in the chlorine produced to that in the treated water was 0.866.
        4,000원
        23.
        2014.10 구독 인증기관·개인회원 무료
        Imported Allium hookeri is sometimes infected by some quarantine nematodes like Meloidogyne spp., Pratylenchus spp. Hot water treatment(HWT) is reported as the most effective treatment method for disinfection of nematodes. The primary goal of this research was to determine the temperature tolerance of Allium hookeri and lethal temperature of Meloidogyne spp., preferably in the range of 5~30minutes at 48~53℃. Second stage juveniles of Meloidogyne spp. were successfully eliminated in hot water bath treated at 48℃ within 1 minute. Egg hatching was suppressed completely at 48℃ more than 26 minutes. No evidence of growth damage was observed on plants treated with HWT even at 48℃ for 30 minutes and 49℃ for 10 minutes. Therefore, the optimum range of HWT is recommended at 48℃ for 30 minutes and 49℃ for 10 minutes on Allium hookeri infected root-knot(Meloidogyne spp.) nematode.
        24.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        인구의 증가와 산업의 발전으로 물에 대한 수요가 점차 증가하고 있는 상황에서 안전하고 지속가능한 수자원을확보하기 위한 방법으로 분리막을 이용한 수처리가 널리 사용되고 있다. 수처리장에서 가장 널리 사용되고 있는 분리막 중 하나인 폴리아마이드 분리막은 분리막 공정 전 단계에서 수행되는 염소살균 처리 후에 잔류하는 염소에 의해 화학적/구조적으로 영향을 받고 성능이 변화하는 것으로 알려져 있다. 본 논문에서는 pH에 따라 수중에 용해되는 염소의 종변화 및 염소에노출시 폴리아마이드 분리막의 표면 성질 변화와 성능변화의 원리를 다루었다.
        4,300원
        25.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.
        4,300원
        26.
        2009.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program CONTAM2.4. This model include disinfection system which is consist of dilution, filtration, UVGI(ultra violet germicidal irradiation). It's energy consumption was also analyzed through the linked model of CONTAM and TRNSYS according to the combination of components. The comparison of total energy consumption through energy analysis revealed that adjusting the air change rate of the UVGI air sterilizer to maintain the same indoor microbe removal capability was more advantageous in terms of energy consumption.
        4,000원
        27.
        2009.02 구독 인증기관 무료, 개인회원 유료
        In this study, disinfection effect of coliform group treated with ozone was analyzed for the effluent discharging from activated sludge treatment process in hospital wastewater treatment plant. Based on these results, it aims to get basic data to establish the disinfection facility in hospital wastewater treatment, suggesting affecting factors according to hydraulic retention time of the activated sludge process and design basic factors necessary to ozone disinfection. Removal efficiencies of coliform group for the effluent according to HRT such as 4hr, 8hr, 12hr were analyzed using a lab-scale activated sludge process, respectively. To decay the microorganism regulates the CT value multiplied disinfectant concentration by contact time. CT value is highly correlated with a removal efficiency of coliform group and according to increasing an injected ozone concentration, the CT value was increased.. When HRT was 4, 8, 12 hours , CT value takes place at minimum condition 50, 40, 334 mg/L-min, respectively.
        5,100원
        28.
        2009.02 구독 인증기관 무료, 개인회원 유료
        This study of hospital wastewater by activated sludge wastewater treatment facility for your use of the UV disinfection process in the HRT and the UV intensity UV disinfection coliform group by evaluating the effectiveness of the disinfection facilities to meet basic data is for. Study the active sludge process coliform group emissions alone will not meet the accepted standards of the disinfection process needs to be separate. Active sludge from the same UV dose settling water interfere with my a particle substance acts as an argument between the disinfection effect a point of difference, which requires the removal of material a particle before in disinfect. The higher the UV intensity coliform group HRT long the effects of the disinfection was higher, permitted emission standards 3,000 EA/mL to meet UV dose said the 82 mJ/cm2. Existing water pollution prevention facilities, the design of the UV dose 2,310 mJ 1m/cm2 the a safety factor 50% of the company considered the same as after consideration, 120 mJ/cm2 to about 19 times higher than the results of the experiment setup, and of the existing water pollution prevention facilities UV disinfection equipment is installed, the excess.
        4,300원
        29.
        2008.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라 농촌현실에 적합하면서 고품질의 친환경 농산물 생산을 위한 청정용수공급이 가능한 FDA 시스템을 개발하였다. 기존의 필터제품의 문제점을 개선하고 보다 경제적이고 기능적인 면을 고려하여 시설재배단지에 청정용수공급을 목표로 시설용수공급시스템을 개발하였다. 시설용수 공급시스템 모듈통합기법으로 개발된 FDA시스템은 여과와 흡착 그리고 자외선 모듈을 거치는 과정으로 구성되어 있다. 본 제품의 시작품 생산은 3단계의 평가과정을 거쳐 진행 되었다. 이 과정을 통해 시설용수공급시스템의 구성품별 사양을 제시하고 적정처리용량 및 모듈통합기법을 개발하였으며, 현장 설치지역(시설재배농가)의 재배현황 및 수질을 조사하여 적합한 시설용수 공급시스템 요소기술(살균, 여과)을 설계하였고, 실제 현장에 적용할 수 있는 시작품을 제작하여 현장 설치를 위한 실내 성능시험을 수행하였다. 또한 시작품 현장 설치 후 시설용수 공급시스템 유입 전․후 수질분석을 실시하였으며 모니터링을 통해 시설재배용수 온도조절장치와 폭기 장치에 대한 개선방안을 제시하여 시작품의 보완제작을 실시하였다. 시작품의 현장적용성 평가에서는 시작품의 수질정화능력평가 및 사용자 입장에서의 개선점 파악을 실시하였는데 그 결과 시스템의 수질정화능력은 목표치 이상이었으나, 수온유지, 저수조 용량문제, 누수현상, 역류현상, 적정수압유지 등의 개선점이 파악되었다.
        4,000원
        30.
        2008.06 구독 인증기관 무료, 개인회원 유료
        Saline-tab water (2.5 L) with 0, 2.5, 5, and 10% saline solution contaminated by P. aeroginosa or S. aureus, was electrolyzed with constant electrical current of 2A or 4A for different time durations (1, 2, 4, 8, and 16min). The electrolysis with 2A-4min showed disinfection effect against P. aeroginosa of 105 CFU/㎖ in all saline concentrations. When the electrical current was raised to 4A, P. aeroginosa of 106 CFU/㎖ was disinfected in 4 min. S. aureus of 105 CFU/㎖ was disinfected with 2A-2 min in all saline concentrations. S. aureus of 106 CFU/㎖ was completely disinfected with 2A-8 min. To compare the effect of constant current electrolysis with that of intermittent current electrolysis, solution contaminated with P. aeroginosa of 106 CFU/㎖ was electrolyzed with several pairs of intermittent current of 2A for 2 min followed by 2min pause. Disinfecting effect of intermittent electrolysis was very similar to the constant current electrolysis without pause in 16 min. The present study demonstrated that the direct electrolyzing process with no septum membrane is a convenient and economic sterilization method.
        4,000원
        32.
        2004.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It has been confirmed that some Trihalomethanes (THMs) suspected as carcinogens, can be formed during chlorination for water supply through the reaction of chlorine and humic substances in water. The electrochemical characteristics on activated carbon fiber filter (ACF) electrode were investigated to remove the THMs in the chlorination process of drinking water. The electrochemical removal efficiency depended on the applied voltage and flow rate. In this study, the best result showed that the removal efficiency of THMs was higher than 99%.
        4,000원
        33.
        2003.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        변색된 종자에서 분리된 P. wasabiae에 접종된 종자는 평균 52.4%의 낮은 발아율을 보였으나 benomyl 침지처리에 의해 발아율이 83.3%로 향상되었다. 멸균 토양에 파종된 접종종자는 28.0%의 먹들이병, 12.7%의 모잘록병 발병률을 보였으나, benomyl로 침지처리된 종자는 먹들이병 6.0%, 모잘록병 4.7%의 낮은 발병률을 나타냈다. P. wasabiae가 접종된 토양에 공시 약제로 처리된 종자를 파종한 결과 먹들이병 발병률은 약제를 처리하지 않은 종자의 32.0%에 비해 benomyl 침지처리에서 12.0%로 발병이 억제되었고, 모잘록병은 10.7%의 가장 낮은 발병률을 보였다.
        3,000원
        34.
        2002.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Traditionally, ultraviolet (UV) has been used for treating the pressure sore and skin wound. The effects of UVA and UVB radiation on disinfection have been reported. The purpose of this study was to examine the effectiveness of UVC radiation on disinfection of Escherichia coli, Staphylococcus aureus, Salmonella typhimurium in vitro. Three bacterium were radiated by UVC (250 nm, 20 seconds) and incubated at for 24 hours at the agar culture medium. Kill rates of all three bacterium were 99.9%. UVC radiated on three kinds of bacterium for 30 or 60 seconds. Kill rates were 99.9% both 30 and 60 seconds. This data suggests that UV light at 250 nm could be a useful method to minimize infection and shorten healing time in pressure sore and skin wound condition.
        4,000원
        35.
        1993.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The effects of chlorine dioxide on the oxidation of phenol and disinfection were studied in the various test water conditions. With the 0.3mg/l of chlorine dioxide dose, the spiked phenol(initial concentration: 0.1mg/l) was completely oxidized within 10 minute. The removal rate of phenol was much faster in distilled water than in ground water and filtered water. The applied dose of chlorine dioxide concentrations higher than 0.2mg/l was sufficiently enough for the complete oxidation of phenol. However, with 0.1mg/l of dose, chlorine dioxide can oxidize only 20% of the spiked phenol. The reactive substances present in test water may influence the chlorine dioxide demand in water. pH effect of oxidation rate was also investigated. Increasing the pH, the removal rate of phenol was found to be increased. The disinfection test of chlorine and chlorine dioxide were conducted and compared. The lethal effect for the both disinfectants are similarly powerful. The time for 99% inactivation of E. coli was obtained within 120 sec with the 0.2mg/l of each dose.
        4,000원
        36.
        1980.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 시험은 도입남양재 원목에 부착 또는 서식하는 유해병해충의 방제를 목적으로 실시하는 해수수침소독에 있어 농약의 소요량기준을 설정함을 목표로 실시한 것으로써 결과를 요약하면 다음과 같다. 1. 우리나라에 도입되는 남양재 원목의 평균 길이는 11.12m이었으며 직경은 69.55cm이었다. 2. 원목의 전재적에 대한 부상재적은 평균 이었다. 3. 원목의 전재적에 대한 부상표면적의 비의 값은 2.3356( 신뢰수준)이었다. 4. 원목의 전재종 대 부상표면적에 대한 표본추출오차는 1본선내 원목간의 오차(0.2087)가 10본선간의 오차(0.2952)보다 적었다. 5. 원목 당 농약의 적정소요량은 수동식살포기를 이용하는 경우 0.368cc, 그리고 동력분무기를 이용하는 경우는 0.295cc이었다. 6. 예를 들어 남양재 원목 을 도입하여 동력분무기로 해수수침소독을 실시하는 경우 농약소요량은 다음과 같이 계산된다. .
        4,000원
        37.
        2019.04 KCI 등재 서비스 종료(열람 제한)
        본 연구는 대전, 충청지역 초음파실 종사자를 대상으로 병원감염관리에 관한 설문 조사를 실시하여 분석 하였고, ATP를 이용하여 임상에서 사용되는 초음파 Probe의 오염도를 측정하였으며, 70% 알코올 이용하여 소독한 후 결과를 확인하였다. 기본적인 조사 대상자의 일반적인 특성 및 직종 별 대상자의 특성으로 나누어 학력, 직종, 초음파 전문자격증 보유 유무, 기관 내 감염 담당 부서 및 감염 교육의 여부를 분석하였다. 검사 후 젤 제거 여부 및 방법, Probe의 소독여부 및 변수 별 상관분석을 수행하여 초음파 Probe의 세균감염에 관한 인식 및 세척 및 소독에 대한 수행 정도를 분석하였다. 검사 후 Probe 세척에 관하여 수건을 가장 많이 사용하였으며, Gel 용기는 3개월 이상 교환하지 않는 것으로 나타났다. 70% 알코올 소독 후 ATP 오염도는 1055.4±944.2에서 133.5±93.2으로 감소하였고 통계적으로 유의한 것으로 분석되었다.(ρ<0.01) 병원 균종은 CNS, Gram positive bacillus, Micrococcus species 검출되었다. 이를 해결하기 위해 시중에서 손쉽게 구할 수 있는 70% 알코올을 이용하여 소독을 실시하였으며 소독 후 병원균종은 검출되지 않았다. 연구 결과 초음파실을 관리하는 의료인 또는 의료기사 등은 감염관리에 대한 주기적인 교육과 감염예방에 대한 노력이 필요하다고 볼 수 있으며, 70% 알코올은 병원균 사멸에 효과적인 것으로 나타났다. 따라서 의료기관은 적극적인 병원감염관리 교육을 실시하여 종사자들의 병원감염에 관한 인식을 개선하고, 환자 감염 예방에 기여해야 할 것이다. 또한 본 연구 결과를 적절히 활용한다면 초음파 Probe를 매개로 한 감염 예방에 도움이 될 것으로 사료된다.
        38.
        2017.06 KCI 등재 서비스 종료(열람 제한)
        본 연구는 황토유황을 활용하여 벼 키다리병 발병을 최소화할 수 있는 최적 종자소독조 건을 선발하기 위해 수행되었다. 키다리병에 이병된 ‘신동진’ 품종 벼 종자를 공시하였고 황토유황 농도, 침지온도, 시간, 온탕여부를 구분하여 실내 및 온실검정을 통해 침지시간은 48시간, 침지농도는 1%로 최적 소독조건을 선발하였다. 그리고 모판과 포장시험을 수행하 여 온탕처리 후 20℃, 1% 황토유황에 48시간 침지 처리구와 30℃, 1% 황토유황에 48시간 단독 침지할 때 가장 효과가 높았다는 것을 확인하였고 위 처리조건으로 소독한 종자가 육 묘, 이앙, 출수기를 거치면서도 100%의 높은 방제효과가 유지되는 것을 확인할 수 있었다. 그러나 20℃에서 1% 황토유황으로 침지한 처리구에서는 포장에서 78.2%의 낮은 방제가를 보였다. 또한, 온탕소독만 수행한 처리구에서도 60℃, 10분간 충실히 수행될 경우 효과적인 벼 키다리병 방제가 가능함을 보여주었지만 온탕처리 후 황토유황으로 추가 침지함으로서 많은 양의 종자를 소독할 때 좀 더 나은 키다리병 방제 효과를 가져다 줄 수 있을 것으로 판단된다. 이상의 결과를 종합하여 볼 때 농가에서 온탕소독기와 종자소독기 둘 중 한가지 만 구비하더라도 황토유황을 이용하여 충분한 소독효과를 낼 수 있기 때문에 현장에서 보 다 쉽게 활용될 수 있을 것으로 판단되며 제조방법이 쉽고 비용이 적게 드는 황토유황의 특성상 농가의 경영비 절감효과도 클 것으로 기대된다.
        39.
        2017.04 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        신선 농산물의 비가열 살균에 사용되는 살균소독제는 처리시간과 살균소독제의 농도에 비선형적인 감균효과를 나타낸다. 따라서 실제 사용에 있어서는 적정 농도와 적정시간에 대한 고려가 매우 중요하다. 본 연구에서는 희석염산(6%, v/v)을 원료로 생성한 미산성 차아염소산수(slightly acidic electrolzyed water, SlAEW)(20±1℃에서의 유효염소 30 ppm, ORP 562±23 mV, pH 6.4)로 4종의 채소류(상추, 깻잎, 치콘 및 케일)에 대한 미생물 저감 특성을 분석하여 비가열 살균공정설계에 필요한 살균효과를 평가하였다. SlAEW에 30분간 3회 침지하면서 핵심인자인 유효염소와 미생물군수 및 잔류 미생물군수와의 관계를 분석하였다. 대부분의 총균수 감소는 1차 침지 초기 10분간 이루어졌으며 4종의 채소류에 생존하는 3 log CFU/g의 총균수가 침지를 통해 감소시킬 수 있는 한계값으로 판단되었다. 또한 SlAEW에 10분간 침지함으로써 감소시킬 수 있는 균수는 평균적으로 약 2 log CFU/g이었다. 초기 10분후의 감소된 유효염소는 상추, 깻잎, 치콘 및 케일에 대해 각각 2.2 ppm, 2.0 ppm, 1.7 ppm 및 2.5 ppm이었고 감소된 유효염소량의 약 50-80%가 초기 10분내에 감소되었다.
        40.
        2017.04 KCI 등재 서비스 종료(열람 제한)
        In this study, we examined the suitability of ten disinfection models for predicting the inactivation of Artemia sp. via single or combined physical and chemical treatments. The effect of Hydraulic Retention Time (HRT) on the inactivation of Artemia sp. was examined experimentally. Disinfection models were fitted to the experimental data by using the GInaFiT plug-in for Microsoft Excel. The inactivation model were evaluated on the basis of RMSE (Root Mean Square Error), SSE (mean Sum Square Error) and r2. An inactivation model with the lowest RMSE, SSE and r2 close to 1 was considered the best. The Weibull+Tail model was found to be the most appropriate for predicting the inactivation of Artemia sp. via electrolytic treatment and electrolytic-ultrasonic combined treatment. The Log-linear+Tail model was the most appropriate for modeling inactivation via homogenization and combined electrolytic-homogenization treatment. The double Weibull disinfection model was the most suitable for the predicting inactivation via ultrasonic treatment.
        1 2 3 4