검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 456

        162.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A scientific and objective sound exposure criterion for underwater sound damage on fish has been required since there has been many disputes between an underwater sound maker and a fish damage receiver. The existing criteria are still incomplete scientifically owing to a degree of variability of underwater sounds, diversity of fish hearing sensitivity and damage types, etc. This study reviews existing studies on a hearing mechanism of fish species, manmade underwater sound characteristics and sound exposure assessment parameters, and recent sound exposure criteria. A governing equation for damage coverage estimation and damage coverage dependency on sound source level, ambient noise and transmission loss are also reviewed and interpreted based on sound exposure environments. The foreign and Korean (National Environmental Dispute Medication Commission) criteria are reviewed and compared based on scientific aspects. In addition, the deficit and limit of Korean criteria are presented. The objective of this study is to give a direction for related researches and legislation of sound exposure criteria on fish.
        5,800원
        163.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study measured and analyzed the heavy metal (Cd, As) content of fine dust in the city of Gwangyang, Jeonnam from September 19 to September 22, 2016. For cadmium, the arithmetic average was 0.21 ng/m3 (0.12~0.49 ng/ m3), which did not exceed the WHO's recommended level. The average of arsenic was 2.41 ng/m3 (0.30~142.08 ng/ m3) and the geometric mean was 11.18 ng/m3, which exceeded the WHO's recommended standard in 16 out of 24 measurements. In the case of cadmium, the CTE of male was 9.22 × 10−8 RME 1.91 × 10−7 and the female CTE was 9.44 × 10−8 RME 1.92 × 10−7, which did not exceed the EPA limit of CTE 2.18 × 10−5 RME 1.51 × 10−4 for men and CTE 2.23 × 10−5 RME 1.51 × 10−4 For women, CTE 2.23 × 10−5 RME 1.51 × 10−4 results were obtained, which exceeded the EPA's recommended limit and also exceeded the maximum allowable limit of 10-4.
        4,000원
        164.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 자기공명검사실 내 자기장을 측정하여 방사선사의 직업적 자기장 노출 정도를 산출한 후 주기적인 자기장 노출에 따른 발현 증상과 증상발현에 직접적으로 작용하는 영향 인자를 알아보고자 한다. 대상 및 방법 : 자기공명검사실에서 근무하는 방사선사 37명을 대상으로 일일 개인 자기장 노출정도와 그에 따른 증상을 선정하여 직업적 노출 관련 설문지를 작성한 후 주기적인 자기장 노출 시 발현 증상과 영향인자를 조사하였다. 개인 노출정도는 Tesla meter(EPRI, 3-axis matrolab THM-1176 PDA)를 이용하여 P1(panel), P2(upper table), P3(middle table), P4(lower table) 위치에서 자기장을 측정하였고, 검사실 내 방사선사의 행동유형을 4가지(이전 검사 정리 및 다음검사 준비(A), 스캔 전(B), 조영제 주입(C), 스캔 후(D)로 나누어 분석한 후 일일 개인 자기장 노출정도를 산출하였다. 측정 장비는 서울 소재 U병원의 자기공명영상장치(Avanto 1.5T, Skyra 3.0T, Achieva 1.5T, Achieva 3.0T, Ingenia 3.0T)를 측정하였으며, 직업적 노출 관련 설문지는 선행논문을 토대로 작성하였고, 설문은 일원배치분산분석으로 검증하였다. 결 과 : 자기장은 Ingenia 3.0T(P1=8670G, P2=15500G, P3=630G, P4=70G)에서 가장 높게, Achieva 1.5T(P1=2370G, P2=5480G, P3=230G, P4=20G)에서 가장 낮게 측정되었다. 방사선사의 행동유형은 A일 경우 P1=5sec, P2=18sec, P3=65sec, P4=55sec의 시간이 소요되었으며, B일 경우 P1=1min 12sec, P2=10sec, P3=18sec, P4=12sec, C일 경우 P1=14sec, P2=8sec, P3=30sec, P4=5sec, D일 경우 P1=12sec, P2=8sec, P3=39sec, P4=10sec의 시간이 소요되었다. 위 결과를 이용하여 개인노출정도를 산출한 결과 하루 평균 8명의 환자를 검사한다는 가정 하에 일일 94.8분으로 노출되었다. 이를 바탕으로 작성한 직업적 노출 관련 설문 결과 영향 인자 중 성별은 유의한 차이가 없었으며, 연령별과 근무년수별은 유의한 차이가 있었다. 영향 인자에 따른 유의한 발현 증상을 살펴보면 연령별에서는 흐린 시야(f=3.499, p=0.027)가 유의하였고, 근무년수별에서는 어지러움(f=2.969, p=0.046), 잘 안들림(f=5.298, p=0.006), 섬광(f=4.019, p=0.017), 두통(f=8.078, p=0.001), 피로(f=8.135, p=0.01), 집중력문제(f=3.608, p=0.025), 머리가 아찔함(f=3.808, p=0.021), 근육경련(f=4.067, p=0.017) 등이 유의하게 나타났다(p>0.005). 결 론 : 기존 선행 연구들에 따르면 고 자기장에 노출 될 경우 여러 가지 발현 증상이 나타난다고 보고하였는데 본 연구에서도 개인 노출 정도가 누적됨에 따라 이와 유사한 증상을 보였다. 현재 직업적 자기장 노출에 관한 연구는 미비한 실정이며, 특히 가장 높은 자기장에 주기적으로 노출되는 방사선사에 대한 연구는 전무한 실정이다. 즉 이러한 영향이 어떠한 작용을 하는지 밝혀지지 않고 있으며 향후 어떠한 위해로 나타날지 알 수 없다. 따라서 방사선사의 직업적 자기장 노출에 관한 체계적인 연구가 필요할 것으로 사료된다.
        4,000원
        165.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to analyze the climate change exposure of fisheries and fish species in the southern sea of Korea under the RCP climate change scenarios. The extent of exposure was calculated through weighted sum of the sea temperature forecasted by National Institute of Fisheries Science, and the weight were obtained from the time-space distribution of each fisheries or species, based on the micro-data for the fishing information reported by each fisherman. Results show that all the exposed sea temperature of RCP8.5 is higher than that of RCP4.5 in year 2100 as well as in near 2030, therefore it is thought to be very important to reduce the GHG emission even in the short term. The extent of exposure was analyzed to be comparatively high especially in the fisheries such as anchovy drag nets and species like cod, anchovy and squid. Meanwhile the method of this study is considered to be excellent to obtain the accurate extent of exposure under RCP scenarios, and therefore it is applicable on assessing the vulnerability of climate change in fisheries.
        4,600원
        170.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to assess RF-EMF exposure levels in indoor daycare centers in a Metropolitan city. RF-EMF measurements were collected and surveyed from 50 volunteer daycare centers in the Korea between October 2013 and October 2014. Through our research, it was found that the main exposure source for indoor daycare centers is the frequency bands for TV and Radio broadcasting (FM: 88.1~107.9 MHz), mobile phone (869~894 MHz, 1840~1870 MHz, 1885~2170 MHz), wireless LAN and home electronics, etc., including TRS, Wireless Data Communication. The RF-EMF exposure levels for all daycare centers were far below the recommended standards of EMF Guideline Korea and international reference levels proposed by ICNIRP (International Commission on Non-Ionizing Radiation Protection). However, in terms of long term health effects some uncertainty exists, and thus minimizing exposure may reduce this uncertainty. The data we collected will be useful data for determining RF-EMF management and risk communication at daycare centers.
        4,000원
        171.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Although piglets have been delivered by embryo transfer (ET) with in vitro produced (IVP) embryos and blastocysts, a success rate has still remained lower level. Unlike mouse, human, and bovine, it is difficult to a production of piglets by in vitro fertilization (IVF) because of an inappropriate in vitro culture (IVC) system in pig. Therefore, the present study was conducted to investigate whether minimized exposure time in IVC can improve the pregnancy and delivery rates of piglets. Immediately after IVM, the oocytes were denuded and co-incubated with freshly ejaculated boar semen for 3.5 to 4 hours at 38.5 ˚C under 5% CO2 in air. To avoid long-term exposure to in vitro state, we emitted IVC step after IVF. After that the presumptive zygotes were transferred into both oviducts of the surrogate on the same day or 1 day after the onset of estrus. Pregnancy was diagnosed on day 28 after ET and then was checked regularly every month by ultrasound examination. The 3 out of 4 surrogates were determined as pregnant (75%) and a total of 5 piglets (2 females and 3 males) were delivered at 118.3 ± 2.5 days of pregnancy period. In conclusion, a short-term exposure time may be an important factor in the production of IVP-derived piglets. It can be apply to the in vitro production system of transgenic pig by IVF, cloning, and pronuclear microinjection methods.
        4,000원
        172.
        2016.04 구독 인증기관·개인회원 무료
        A response surface methodology (RSM) was used to evaluate how pH and ionic strength (IS) affect the fate (i.e. size and colloidal stability) of an SC formulation containing the pyrethroid β-cyfluthrin. The response surfaces determined under a range of environmentally relevant conditions were then used to assess the toxicity of the SC formulation of β-cyfluthrin to D. magna. The changes in hydrodynamic diameter (HDD) and colloidal stability as determined by zeta potential measurement were closely related to either or both of the change in pH and IS with the linear factor of IS being the most significant factor affecting those changes. Thus, the concentration of SC formulation of β-cyfluthrin remaining in the water column was dependent on the pH and IS conditions and highest when the colloidal suspension contained small particles or a lack of agglomeration leading to sedimentation of the particles. The toxicity results show correspondingly higher toxicity to D. magna when exposed to the SC formulation of β-cyfluthrin when pH and IS conditions favor formation of either the smallest HDD or most stable colloidal suspensions.
        173.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% (62.3 μGy vs. 125.1 μGy). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from 320.8 μGy to 284.7 μGy (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.
        4,000원
        174.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers’ health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.
        4,000원
        179.
        2015.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The effects of coating thickness on the delamination and fracture behavior of thermal barrier coating (TBC) systems were investigated with cyclic flame thermal fatigue (FTF) and thermal shock (TS) tests. The top and bond coats of the TBCs were prepared by electron beam-physical vapor deposition and low pressure plasma spray methods, respectively, with a thickness ratio of 2:1 in the top and bond coats. The thicknesses of the top coat were 200 and 500 μm, and those of the bond coat were 100 and 250 μm. FTF tests were performed until 1140 cycles at a surface temperature of 1100 oC for a dwell time of 5 min. TS tests were also done until more than 50 % delamination or 1140 cycles with a dwell time of 60 min. After the FTF for 1140 cycles, the interface microstructures of each TBC exhibited a sound condition without cracking or delamination. In the TS, the TBCs of 200 and 500 μm were fully delaminated (> 50 %) within 171 and 440 cycles, respectively. These results enabled us to control the thickness of TBC systems and to propose an efficient coating in protecting the substrate in cyclic thermal exposure environments.
        4,000원
        180.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 적설하중 산정을 위한 노출계수를 결정 하는데 필요한 기초자료를 제공하기 위하여 각국의 온실 구조설계기준에서 제시된 노출계수들을 비교분석하였고 우리나라의 각 지역별 노출계수를 결정하고 결정방법에 대하여 개선방안을 분석하였으며 연구결과를 요약하면 다음과 같다. 각국의 노출계수 기준을 비교분석한 결과 노출계수에 영향을 미치는 주요인자는 노풍도, 풍속, 바람막이의 유무인 것으로 분석되었다. 또한 일본을 제외한 각국의 기 준을 종합하면 노출계수는 3가지 단계로 구분되며 바람에 완전히 노출되고 바람이 센 지역의 노출계수는 0.8(0.9), 바람에 부분적으로 노출된 지역은 1.0(1.1), 바람 막이가 조밀하게 설치된 지역은 1.2로 나타낼 수 있다. 따라서 온실의 적설하중 산정을 위한 노출계수는 적용의 용이성을 고려한다면 3단계로 구분하여 제시하는 것이 바람직할 것으로 판단된다. ISO 4355기준에 따라 우리 나라 94개 지역에 대한 노출계수를 산정한 결과 대관령 (0.5)과 여수(0.6)를 제외한 모든 지역의 노출계수가 1.0 과 0.8 두 가지로 대별되었다. 우리나라의 내륙지역이 해안지역에 비해 상대적으로 더 큰 강설 확률을 가지며 최대풍속이 5m·s-1 이상인 일수가 더 작은 것으로 분석되 었다. 우리나라의 노출계수는 3단계로 구분하여 해안 지역을 중심으로 한 바람이 강한 지역을 0.8로 하고 내륙 지역은 1.0으로 하며 촘촘한 바람막이가 있는 경우는 일본을 제외한 각국에서 적용하고 있는 값인 1.2로 결정하 는 것이 바람직할 것으로 판단되며, 임계풍속 5.0m·s-1 이상 일 수에 따른 지역별 구체적인 노출계수는 추가적인 연구를 통해 결정할 필요가 있다.
        4,000원