In the present study, a calorimeter was used to experimentally investigate the heating capacity and COP changes according to the pipe length of a variable capacity A/C system with long pipes. Cooling capacity, COP, and compressor discharge temperature were obtained by changing pipe lengths and loading duties at fixed indoor and outdoor temperatures. And the operation status and cycle change process of the A/C system were investigated using some experimental data and P-h diagrams. As the pipe length changes, the heat transfer within the cycle and the operating load of the compressor change, so the heating capacity and COP of the system change. At the same loading duty, as the pipe length increases, the heating capacity and COP decrease. As the loading duty increased, the heating capacity increased almost linearly, but the COP decreased. Since the long pipe experimental value for the compressor discharge temperature has a temperature deviation of up to 1 7℃(50m, L/D : 10/10) from the correlation equation, the optimal correlation equation must be derived through additional research.
In this study, the heating performance of a variable capacity A/C system was experimentally studied. A psychrometric calorimeter was used to obtain performance data of the A/C system using PWM(pluse width modulation) method and compare it with the compressor discharge temperature correlation equation. Heating capacity, COP, and compressor discharge temperature were obtained by changing indoor and outdoor temperatures, refrigerant amount, and loading duty. The following results were obtained by selecting 5 types of refrigerant amount, 3 types of outdoor temperature (fixed indoor temperature), and 2 types of loading duty. As the outdoor temperature increases, heating capacity and COP increase. Heating capacity was affected by both outdoor temperature and loading duty. However, COP was more influenced by outdoor temperature. The effect of increasing the amount of refrigerant on the performance of the A/C system was not significant. Additionally, the temperature deviation between the existing compressor discharge temperature correlation equation and the heating experiment data was about 5.1℃ at the maximum loading duty.
Korea's facility horticultural heating costs account for a high proportion. Therefore, it is the most important factor to consider in greenhouse construction. It is important to assess the heating load of greenhouses. But there is not much data from the weather station. This study determined the heating load for each segmented area using the spatial correction method. The heating degeneration calculated from standard weather data (AHDH and BHDH) and total weather data (CHDH and DHDH) is consistent. However, there was a big difference between AHDH and DHDH. Therefore, the updated heating load data for each region is needed. Each of the four types of set temperatures (8℃, 12℃, 16℃, 20℃) was provided, and the heating temperature setpoint (℃) for each region of 168 cities and counties was presented. As a result of the analysis, the reliability of about 99% was confirmed in most of the regions suggested in this study. By using the calculated heating load for each region, it is possible to predict and utilize energy consumption and management costs.
In this study, the effect of crown heating on the cultivation environment, budding, flowering and yields of strawberry was analyzed. In December, January, and February, when the outside temperature was low, the average strawberry crown temperature at daytime in the test zone was 1.3°C higher than that in the control zone, and the average strawberry crown temperature at nighttime in the test zone was 2.7°C higher than that in the control zone. The average bed temperature at daytime in test zone was 1.7°C higher than that in the control zone, and the average bed temperature at nighttime in test zone was 2.4°C higher than that in the control zone. As a result of performing correlation analysis and regression analysis on strawberry crown temperature and budding period, the correlation coefficient was -0.86, which tended to be shorter as the crown temperature was higher, and the determination coefficient was 0.74. The total yields of strawberry during test period were 392.6 g/plant for test greenhouse and 346.0 g/plant for control greenhouse respectively. As for the quality of strawberries, the ratio of 2L (very large) grades and L (large) grades was 62.4% in the test greenhouse and 58.5% in the control greenhouse, indicating that the proportion of high quality strawberries was higher in the test greenhouse.
본 연구는 등유를 사용하는 농업용 난방기에서 배출되는 가 스를 포집하고, 농업용 난방기의 사용 연식에 따른 이산화탄 소의 배출농도를 파악하고자 수행되었다. 선형 회귀분석의 결과로 농업용 난방기의 연식에 따른 이산화탄소의 배출량은 R2 = 0.84로 y = 26.99x+721.98의 식을 따른다고 나타났다. 농업용 난방기의 사용 연식에 따라 세 그룹으로 분류하여 분 산분석을 수행하였다. 분산분석을 수행한 결과, 분석을 위해 설정한 유의확률 0.05보다 작은 2.1961×10-13으로 나타났으 며 이는 적어도 한 그룹에서 차이가 나타난다는 것을 의미한 다. 본 연구에서는 농업용 난방기의 기본적인 배출농도의 차 이를 분석하고자 기기의 제작사와 상관없이 농업용 난방기의 기기 연식만을 고려하여 배출가스 데이터를 수집하였다. 기 기의 연소 방식에는 제작사에 따라 연소 방식에 차이가 미미 하게 있었을 것으로 판단되며 데이터 변수의 개수가 늘어난다 면, SVR(support vector regression) 기반의 선형회귀 분석 등 을 실시하여 농업용 난방기의 이산화탄소 데이터가 온실가스 발생량 파악에 더욱 활용도가 높아질 것으로 판단된다. 추후 연구에서는 더욱 세분화된 데이터의 수집 방식을 따라 더욱 높은 정확도를 가진 결과값을 도출할 수 있다고 판단된다. 이 처럼 우리나라의 농업 분야에서 용도별 온실가스 발생량을 조 사하기 위하여 고정형 농기계인 농업용 난방기의 이산화탄소 발생량을 정확히 파악하여 온실가스 배출량 조사에 활용할 수 있을 것으로 판단된다.
본 연구는 난방 개시 온도와 CO2 시비의 효율을 알아보기 위해 수행되었다. 난방 개시 온도 실험은 9℃, 12℃, 15℃로 구분하여 목표 온도보다 낮아지면 전기 온열기구가 작동하게 하였다. CO2 시비 농도 실험은 액화탄산가스를 이용하여 무 처리, 500μmol·mol-1, 800μmol·mol-1으로 7시부터 12시까 지 처리하였다. 생육 특성으로 초장, 경경, 엽수, 엽면적, 생체 중, 건물중을 조사하였고, 200g 넘는 과실만을 대상으로 수량 을 조사하여 경제성 분석을 하였다. 상위엽에 대한 광합성 측 정을 하여 처리에 따른 포화점을 산출하였다. 애호박의 광포화 점은 587μmol·m-2·s-1이였고 CO2 포화점은 702μmol·mol-1 이 였다. CO2에 의한 Amax값은 9℃, 12℃, 15℃, 500μmol·mol-1, 800μmol·mol-1 순으로 13.4, 17.8, 17.2, 19.6, 17.5μmol CO2·m-2·s-1이었다. 온도 실험에서 9℃는 생육과 착과가 정상 적으로 이루어지지 않았다. 12℃와 15℃는 9℃보다 높았지 만 생육과 생산에서 유의미한 차이를 보이지 않았다. CO₂ 농 도 실험은 생육에서 처리구간 유의한 차이를 보이지 않았지만 800μmol·mol-1의 생산성이 가장 좋았다. 이상의 결과를 종합 적으로 보면 난방 개시 온도는 15℃인 것은 작물 생육과 생산 에는 좋았지만 12℃와 유의적인 차이가 없어 경제적 측면에 서 난방 개시 온도를 12℃로 설정하는 것이 좋은 것으로 보이 며, CO2 시비 농도 800μmol·mol-1를 유지하는 것이 생산량 증가에 효과적이었다.
In the present study, it is conducted to understand the heating performance and compressor operation characteristics according to 7 indoor unit combinations and 3 setting temperatures of the inverter multi-heat pump under heating standard temperature conditions. Heating capacity, COP and compressor frequency are investigated using the multi-calorimeter. The indoor unit combinations are simultaneous operation(A+B+C), partial operation(A+C, A+B, B+C) and independent operation(A, B, C), and the setting temperature is 20, 21, and 30°C. Since the increase in the setting temperature increases the compress frequency, the heating capacity increases, but COP decreases due to the increase in power consumption. The frequency increases as the indoor unit combination capacity increases, and decreases as the setting temperature decreases in the steady state.
This study was carried out to investigate the proper wattage and installation distance for the efficient use of nano-carbon fiber infrared heating lamp (NCFIHL), a heating device advantageous for heating energy saving, when the production of watermelon plug seedlings in the plug seedling nursery in winter season. Six small beds were divided into plastic film, and 700 W and 900 W nano-carbon fiber infrared heating lamps were installed at 100 cm above the bed. 1 lamp at central (control), 60 cm interval (2 lamps), and 40 cm interval (3 lamps) heating lamps were installed in each bed inside the greenhouse. All treatments, except the control, were set to keep the night air temperature at 20℃ after lighting the NCFIHL. The leaf temperature showed a tendency to increase fast as the install distance was narrow. The leaf length and leaf width tended to increase as the installation distance of the 700 W heating lamp was narrow. The compactness was high in 700 W heating lamp with 40 cm of installation distance. Therefore, in consideration of maintaining the set temperature at night, installing 700 W electric lamps at 40 cm was an efficient power and installation distance for watermelon grafted seedlings considering economic feasibility.
The traditional Korean heating system ondol, one of the most important characteristics of Korean architecture, still remains as hydronic floor heating. Various studies have been conducted on the modernization of ondol, but the process of introducing the hydronic floor heating has not been seriously studied so far. Therefore, this paper aims to demonstrate how the hydronic floor heating had been introduced to Korea, taking the 1950s and 1960s Haengchon, Jongam, and Mapo Apartments for example – these three are regarded as the first Korean apartment houses after the Korean War. While Western advanced construction technology was imported for these apartments, various methods of modernizing ondol were also considered. What was remarkable in these attempts is that hydronic floor heating first appeared in Mapo 1st Apartment in 1962, because this is the universal heating method in the present Korea. This fact signifies that the traditional principle of floor heating has been maintained, and it would also be meaningful in terms of architectural exchanges between East and West, if considered along with Wright’s application of the Korean heating principle to his houses since 1930s.
모바일 기반 온실에너지 계산프로그램을 제작하기 위해 먼저 주요 단일 피복재 10종 및 보온재 16종에 대한 열관류율 측정하였다. 또한 피복 및 보온재를 이중 및 삼중으로 다층 설치할 때 열관류율 추정을 위하여 이중 설치시 24조합, 삼중설치 시 59조합에 대한 열관류율을 핫박스를 이용하여 측정하였다. 단일 피복재에서는 PE필름(0.08mm) 대비 PO필름(0.15mm) 이 가장 열관류율이 가장 작고 열절감율이 가장 큰 것으로 나타났다. 단일 보온재에서는 열관류율에서는 외피가 있는 5겹 의 다겹보온커튼이 가장 보온력이 좋은 것으로 나타났다. 또한 단일자재에 대한 열관류율 값과 열저항값을 이용한 피복 및 보온재의 다층설치시의 총 열관류율 값을 산정하였고 실측 값과의 오차를 보정하는 선형회귀식을 도출하였다. 단일재료의 열관류율값에 의한 피복 및 보온재의 다층설치시 열관류율 추정 모형을 개발한 결과 모형평가지수가 0.90(0.5 이상일 때 양호)으로 나타나 추정치가 실측치를 매우 잘 재현 하고 있는 것으로 나타났다. 또한 시험온실을 통한 실증시험결과 예측된 열절감율이 실측치보다 상대오차 2%로 작게 나타나는 것으로 평가되었다. 이러한 연구결과를 기반으로 모바일 기반의 온실 에너지계산 프로그램을 개발하였다. 이 프로그램은 HTML5 표준 웹 기반 모바일 웹 애플리케이션으로 구현하였으며 N-Screen 지원을 통해 다양한 모바일 장치 및 PC 브라우 저에서 동작이 가능하게 제작되었다. 또한 온실 피복(12종) 및 보온재(16종)의 조합별 열관류율 및 난방부하계수를 제공 하여 농민이 모바일로 온실 위치, 형태 및 피복·보온재 등을 반영한 최대 주야간 냉난방부하 및 기간 난방부하를 산정할 수 있다. 대상 온실의 에너지 소비량에 대한 평가가 가능하며 온실의 지역 및 형태에 따라 피복 및 보온재의 최적 선택으로 에너지 절감형 온실 설계가 가능할 것으로 판단되었다.
본 연구에서는 ‘설향’ 딸기의 관부를 부분 난방하고 양액을 온수로 공급하면서 관행 재배 방식에 비해 온실 공간 온도를 낮게 관리하는 딸기 부분 난방 시험을 수행하였다. 정식 후 11월까지는 특별한 처리가 없어 대조구, 시험구 모두 온실 내 환 경이 유사하게 관리되었으며 관부 난방 및 온수 양액을 공급 하기 시작한 12월부터는 야간의 온실 온도, 관부 온도 및 베드 온도가 차이를 보였다. 12월의 온실 야간 평균 온습도는 대조구 7.1℃, 87.2%, 시험구 5.7℃, 88.7%로 시험구의 온도가 낮았으나 관부 난방을 수행함으로써 시험구 온실의 관부 및 베드의 온도를 9.3℃, 12.7℃로 유지하였고, 대조구 온실의 관부 및 베드 온도 7.9℃, 10.8℃보다 높게 관리할 수 있었다. 시험기간 내에서 시험구 온실의 딸기 관부 및 베드 온도는 대조구에 비해 모두 약 2.0℃ 가량 높게 유지되는 것으로 나타났다. 주간에는 온수 양액을 공급함으로써 지하수를 이용했을 때보 다 평균 8.7℃ 높은 온도 양액을 공급할 수 있었고 이로 인해 베드 온도도 약 5.0℃ 가량 높게 나타났다. 시험구에서는 시험 기간 동안 온실 난방, 관부 난방 및 온수 양액 공급에 총 9,475.7×10 3 kcal의 에너지를 소비하였고 대조구에서는 온실 공간 난방에 총 16,847×10 3 kcal의 에너지를 소비하여 시험구에서 대조구 대비 약 43.8%의 에너지 절감 효과를 확인할 수 있었다. 시험구에서 딸기 관부의 온도를 높게 관리함으로써 작물의 생육을 촉진시킬 수 있었고 그로 인해 정식 후 초세가 대조구에 비해 좋지 않았던 시험구의 딸기가 25주 후에는 대조구와 생육적인 면에서 큰 차이가 없는 것으로 나타났다. 딸기의 수확량은 초세가 좋았던 대조구에서 1화방의 수확량이 시험구에 비해 많았으나 2화방, 3화방에서는 관부의 온도를 높게 관리한 시험구의 수확량이 더 많았다. 3월 말까지의 주당 수확량은 시험구 412.7g/plant, 대조구 393.3g/plant로 유의미한 차이는 없었으나 시험구가 대조구에 비해 4.9% 많이 나온 것으로 보아 딸기의 온도 민감부인 관부의 온도를 높게 관리하는 것이 딸기 생육과 생산성에 영향을 미치는 것으로 판단된다.
본 연구는 최근 신소재 단열재로 주목받고 있는 실리카 에어로겔을 이용하여 현재 사용되고 있는 다겹보온커튼의 단점을 보완하고 보온성을 유지 및 향상시킬 수 있는 새로운 조합의 다겹보온커튼을 제작 하여 현장에 설치함으로써 보온성과 경제성을 분석하고자 한다. 실험에 사용된 다겹보온커튼은 실리카 에어로겔이 함유된 부직포를 사용하여 2가지의 조합으로 제작하였으며 시중에 판매, 사용되고 있는 관행 다겹보온 커튼과의 차이에 따른 온습도변화와 연료소비량을 측정하여 비교분석하였다. 실험결과 단동온실과 연동온실에서 다겹보온커튼 차이에 따른 온습도변화는 미세하게 나타났으나, 거의 비슷한 온습도 값을 유지하였다. 이는 실리카 에어로겔을 이용한 다겹보 온커튼이 관행 다겹보온커튼에 비해 온습도 제어 측면에서 문제가 없음을 나타냈다. 난방에너지 비교분석 결과, 실리카 에어로겔을 이용한 다겹보온커튼이 관행 다겹보온커튼에 비해 연료소비량은 단동온실에서 약 15%, 연동온실에서 약 20% 의 연료소비량을 절감한 것으로 나타나 온실의 규모와 사용기 간이 증가함에 따라 난방에너지는 절감될 것으로 판단된다. 실리카 에어로겔 이용 다겹보온커튼이 관행 다겹보온커튼에 비해 통기성과 보온성이 증가되는 것이 확인되었다. 그러나, 연동온실에서 사용된 다겹보온커튼은 관행 다겹보온커튼에 비해 무게가 증가하고 뻣뻣하여 시공성과 작동성이 떨어지는 것을 확인할 수 있었다. 이에 단동온실에서 사용된 다겹보온 커튼에서는 개선사항을 적용하였다. 내부단열재의 교체를 통해 두께를 감소시키고 뻣뻣함을 개선함으로써 농가가 사용하 기에 충분한 가능성이 있다는 것을 확인하였다.
We conducted a study on the possibility of using the power plant's thermal effluent system by using a heating system to utilize the thermal effluent from Jeju Power Headquarters of KOMIPO. In this study, growth information such as the size, leaf area, fresh weight and dry weight of subtropical persimmon fruit (A) in the facility cultivation complex were measured. In the comparison group (B), the growth information of the same crop was measured and compared in an unheated greenhouse near Harye-ri, Namwon-eup, Seogwipo. Fruit size was measured at monthly intervals, and leaf area, fresh weight, and dry weight were measured at new shoot season. Measurement results of A and B growth information, 1) Fruit diameter & length, A grew 7.3% and 9.4% than B, 2) Leaf area, A grew 4.7% than B, 3) Fresh weight, the decrease was 8.9%, but the dry weight was 3.6%, indicating that A contains more nutrients than B. Therefore, if the heating control by supplying thermal effluent to the facility greenhouse, it can contribute to reducing the energy cost and improving quality.
본 연구에서는 고설 딸기 관부(크라운부) 난방시스템을 전기 온수 보일러, 축열조, 순환 펌프, 관부난방 배관 (백색 연질 PE관, 관경 16mm) 및 온도 제어반으로 구성하였다. 관부(크라운부) 난방의 경우 난방 배관을 딸기 관부에 최대한 밀착될 수 있도록 설치하고 배관 위치를 원예용 고정핀으로 고정하였다. 또한 관부 난방시스템의 에너지 효율을 증진하기 위해 축열조 온수 온도를 20~23oC, 관부 온도를 13~15oC로 관리하였다. 관부난방은 전기 온수보일러를 이용하여 20~23oC의 온수를 축열조에 저장하고 순환펌프를 제어하기 위한 온도 센서를 딸기의 관부에 최대한 근접하여 설치하고 온도를 감지함 으로써 관부(크라운부)를 집중적으로 난방하는 방식이다. 시험 온실의 난방 처리는 공간 난방 4oC + 관부난방(처 리 1), 공간 난방 8oC (대조구), 공간 난방 6oC + 관부 난방(처리 2)로 처리하였다. 각 난방처리는 온실 1동에 딸기를 980주를 심었으며, 재배방법은 표준재배법에 준해서 재배하였다. 난방 에너지 소비에 대한 비교시험은 2017년 11월 8일부터 2018년 3월 30일까지 수행되었다. 소비된 누적 전력량은 등유 사용량으로 환산하였고, 등유 소비량은 공간난방 8oC(대조구)의 경우 1,320L (100%), 공간난방 4oC + 관부난방의 경우 928L(70.3%), 공간난방 6oC + 관부난방의 경우 1,161L (88%)로 계측 되었다. 공간난방 4oC + 관부난방(처리 1) 및 공간난방 6oC + 관부난방(처리 2)은 8oC 공간난방(대조구)에 비해 생육 저하, 수확시기의 지연 등이 없이 비슷하게 딸기 수확이 가능하였으며, 29.7% 및 12%의 난방 에너지가 절감되는 것으로 분석되었다.
본 연구는 난방온실의 온도분포 균일화를 위한 기초자료 제공을 목적으로 온수난방 방식의 토마토 재배 온실 에서 난방실험을 통하여 난방배관의 표면온도와 실내기온 사이의 상관관계를 분석하고, 난방배관의 열전달특성 분석과 난방배관 배치의 개선을 통하여 난방배관 표면온도의 편차를 줄이고 균일도를 향상시키기 위한 방안을 도출하였다. 서로 다른 두 온실의 온도분포를 분석하여 최대편차와 균일도를 검토한 결과, 온수의 유량이 많고 난방배관의 길이가 짧게 배치된 온실의 온도편차가 작고, 균일도는 높은 것으로 나타났다. 또한 순환팬을 가동한 경우에 온도편차는 작아지고 균일도가 개선되는 것을 확 인할 수 있었다. 난방배관의 표면온도와 실내기온 사이의 상관관계를 분석한 결과, 두 온실 모두에서 유의적인 (p<0.01) 정적 상관관계가 있는 것으로 나타났다. 온수난방 온실에서 실내기온의 분포는 난방배관 표면온도의 분포에 영향을 받는다는 것을 확인할 수 있었고, 온도편차 가 최소화 되도록 난방배관을 배치함으로써 실내기온 분포의 균일도를 개선할 수 있는 것으로 판단되었다. 난방 배관의 열전달 특성을 분석한 결과 배관의 길이가 길어 지면 온도편차는 커지고, 관내의 유속이 빨라지면 온도 편차는 작아지는 것으로 나타났다. 따라서 지선배관의 길이가 짧아지도록 난방배관을 배치하고, 관내의 유속을 제어함으로써 온실의 온도분포와 환경의 균일성을 개선 할 수 있을 것으로 판단되었다. 국내 온실에서 가장 많 이 사용하고 있는 튜브레일(40A) 방식의 온수난방시스 템에서 하나의 지선배관에서의 온도편차를 3oC 이내로 조절하기 위해서는 관내의 유속이 0.2, 0.4, 0.6, 0.8, 1.0m·s-1일 때 난방배관의 길이는 각각 40, 80, 120, 160, 200m 이내로 제한해야 하는 것으로 분석되었다.
본 연구는 온실의 온도와 CO2농도를 높이기 위해 DME버너용 연료로 DME가스를 사용했을 때 DME 연소가스의 성능을 결정하고 겨울에 상추와 양배추의 엽록소 함량 그리고 무게와 건조무게에 대한 영향정도를 조사하기 위해 수행되었다. 각각 온실1과 온실2에 처방 된 DME-1과 DME-2 처방은 덕트의 평균 DME 유량 17.4 m3 min-1과10.2 m3 min-1으로 구성됐으며, 대조군(DME-3)으로 남겨진 온실3에는 DME 가스가 공급되지 않 았다. DME 공급 시간은 각각 주차 별로 1주차는 하루당 0.5시간, 2주차는 1시간, 3주차는 1.5시간, 4주차는 2 시간으로 설정하였다. 각각 처방마다 엽록소 함량과 상추와 배추의 건조 전, 후 중량을 측정했으며, 연구결과 무처리구인 온실3과 비교하여 온실1과 온실2 의 CO2 농도는 각각 265%, 174% 증가하였고, 온도의 경우 4.8oC, 3.10oC 상승하였다. DME 가스를 제외한 다른 조건이 같은 온실에서 재배된 상추와 양배추의 엽록소 함량과 생체중, 건물중은 온실1에서 (유의적으로) 가장 높았으며, 온실2는 대조구 온실보다 높았다. 이러한 결과는 DME가스 연소에 의한 CO2 농도 차이에 기인된 것으로 판단된다. 일반적으로 가스연소에 의해 발생되는 유해가스 증상은 나타나지 않았으며 동절기 난방과 CO2 공급이 동시에 필요할 경우 DME가스가 기존의 경유 또는 LPG 등을 대체할 수 있는 가능성을 확인하였다. 향후 정밀한 연구를 통하여 효율적인 난방방식으로의 검토가 적극 필요하다고 판단된다.
The purpose of this study is to provide basic data for setting environmental design standards for domestic greenhouses. We conducted experiments on thermal environment measurement at two commercial greenhouses where hot water heating system is adopted. We analyzed heat transfer characteristics of hot water heating pipes and heat emission per unit length of heating pipes was presented. The average air temperature in two greenhouses was controlled to 16.3oC and 14.6oC during the experiment, respectively. The average water temperature in heating pipes was 52.3oC and 45.0oC, respectively. Experimental results showed that natural convection heat transfer coefficient of heating pipe surface was in the range of 5.71~7.49W/m2 oC. When the flow rate in heating pipe was 0.5m/s or more, temperature difference between hot water and pipe surface was not large. Based on this, overall heat transfer coefficient of heating pipe was derived as form of laminar natural convection heat transfer coefficient in the horizontal cylinder. By modifying the equation of overall heat transfer coefficient, a formula for calculating the heat emission per unit length of hot water heating pipe was developed, which uses pipe size and temperature difference between hot water and indoor air as input variables. The results of this study were compared with domestic and foreign data, and it was found to be closest to JGHA data. The data of NAAS, BALLS and ASHRAE were judged to be too large. Therefore, in order to set up environmental design standards for domestic greenhouses, it is necessary to fully examine those data through further experiments.