Recently, active research in Korea and worldwide has begun to focus on gene function and cultivar development using gene editing tools. This research, in addition to studies on edible mushroom, aims to enhance the physical and biochemical characteristics of mushrooms for applications in materials and substance production. For these studies, efficient isolation of protoplasts from the target mushroom is critical. However, several commercial cell wall-lysing enzyme cocktails, including Novozyme234, Glucanex, and Lysing enzymes, have recently been discontinued. In this study, we aimed to identify alternative enzyme systems to replace the discontinued cell wall-lysing enzymes for stable isolation of protoplasts from Ganoderma lucidum. To select an optimal osmotic buffer, enzyme function in 0.6 and 1.2 M Sorbitol, Sucrose, Mannitol, and KCl was assessed. The effect of reaction time was also evaluated. Protoplast isolation efficiency of each alternative enzyme was tested using lysing enzymes from Trichoderma harzianum, Chimax-N, and Yatalase, either individually or in combination. This matrix of studies identified enzymes and optimal conditions that could replace the discontinued lysing enzymes.
본 연구는 중국 상산시 청산관, 백양욕, 희봉구 관광지구 등 총 15개 지구를 대상으로 만리장성 유적지 의 공간활력에 영향을 미치는 요인을 분석하고 공간활력 평가방법을 수립하여 관광지구 개선에 기초 자료를 제공하는 것에 목적이 있다. 연구방법으로는 첫째, 여가활동 관찰기법(SOPARC)을 활용해 탐 방객의 활동특성을 관찰·분석하였다. 동시에 인간·시간·공간의 3차원적 접근방식을 통해 ArcGIS 핵밀 도 추정 알고리즘(KDE)을 이용하여 만리장성 유적 관광지의 활력특성을 분석하였다. 둘째, 탐방객을 대상으로 공간, 편의시설, 동선, 건축 및 자연경관, 역사 문화, 문화 활동 등 15개 항목에 대해 5점 리커트 척도로 설문조사를 수행하였다. 셋째, 전문가 대상 델파이법과 계층분석법(AHP)을 통해 공간지표를 선정하고 지표의 가중치를 설정하여 대상지의 공간활력을 평가하고 활력도 제고를 위한 지침을 마련 하였다. 연구결과는 첫째, 만리장성 유적 관광지의 공간 이용자 중 젊은 층이 절대적인 비율을 차지하였 다. 또한 접근성이 좋고 시설이 잘 갖추어져 공간의 규모가 적절하고 자연경관과 문화경관이 우수하며, 문화활동이 다양하고 활발한 관광지일수록 이용자 간의 혼합도가 높았다. 공간기능이 다양한 관광지 는 공간활동의 다양성도 더 높았다. 둘째, 관광지의 활동 피크 시간대는 주로 오전 10시에서 12시, 오후 3시에서 5시 사이로 나타났으며, 미기후가 쾌적한 관광지에서는 피크 시간대의 활동빈도가 더 높았다. 시설이 잘 갖추어지고 관리가 잘된 공간일수록 활동변동이 적었으며, 경관이 아름답고 문화환경이 우 수한 공간에서는 활력이 오래 지속되었다. 셋째, 주변 인구밀도가 높고 역사요소가 잘 보존되며, 유지 관리가 우수한 관광지일수록 공간 활동빈도가 높았다. 또한 특색 있는 지역산업이 발전하고 상업활동 이 활발하며, 공간의 기능이 다양한 경우 공간집적도가 더 높아진다는 결과를 확인하였다. 넷째, 사례 연구 결과와 만리장성 유적 관광지의 특성을 결합하여 자연환경, 산업공간 기능, 시설 서비스, 문화 및 경관 등 4가지 주요 영향요인을 도출하였다. 델파이법을 통해 1개의 목표층, 4개의 1차 지표, 9개의 2차 지표 및 29개의 3차 지표로 구성된 만리장성 유적 관광지의 공간활력 평가모델을 수립하였다. 이를 토 대로 계층 분석법을 통해 공간활력 평가지표 시스템의 가중치를 결정하였으며, 가중치는 문화 및 경관 활력(45.12%), 자연환경 활력(26.09%), 산업공간 기능 활력(16.89%), 시설 서비스 활력(11.9%) 순으로 나타났다. 이는 관광지의 공간활력을 조성하는 데 있어 문화와 자연경관이 가장 중요하다는 것을 의미 한다. 다섯째, 연구를 통해 도출된 평가지표와 대상지의 현황을 종합하여 만리장성 유적 관광지의 공간 활력 5단계 평가등급을 정의하였다. 각 요인 항목에 점수를 부여해 최종 활력값을 도출할 수 있었으며, 이 값은 공간의 활력정도를 정량적으로 설명할 수 있는 기반을 마련해 주었다. 실제 검증을 통해 구축된 평가 시스템과 5단계 평가등급은 신뢰성이 높았으며, 만리장성 유적지의 공간활력 평가를 위한 새로운 패러다임을 제공했음을 확인하였다.
For low-rise piloti-type buildings that suffered significant damage in the Pohang earthquake, the seismic performance of those designed by codes issued before and after the earthquake has been recently revised. This study started with the expectation that many of the requirements presented in the current codes may be excessive, and among them, the spacing of column stirrup could be relaxed. In particular, the recently revised design code of concrete structures for buildings, KDS 41 20 00, suggests that the column stirrup spacing is 1/2 of the minimum cross-sectional size or 200 mm, which is strengthened compared to KBC 2016, but relaxed than the current KDS, 41 17 00, which is 1/4 of the minimum size or 150 mm. As a result of the study, it was found that the target performance level was sufficiently satisfied by following the current standards and that it could be satisfied even if the relaxed spacing was followed. Therefore, the strict column stirrup spacing of KDS 41 17 00 could be relaxed if a wall other than core walls is recommended in the current guideline for the structural design of piloti-type buildings.
Concrete structures must maintain their shielding abilities and structural integrity over extended operational periods. Despite the widespread use of dry storage systems for spent nuclear fuel, research on the properties of deteriorated concrete and their impact on structural performance remains limited. To address this significant research gap, static and dynamic material testing was conducted on concrete specimens carefully extracted from the outer wall of the High-flux Advanced Neutron Application ReactOr (HANARO), constructed approximately 30 years ago. Despite its age, the results reveal that the concrete maintains its structural integrity impressively well, with static compression tests indicating an average compressive strength exceeding the original design standards. Further dynamic property testing using advanced high-speed material test equipment supported these findings, showing the consistency of dynamic increase factors with those reported in previous studies. These results highlight the importance of monitoring and assessing concrete structures in nuclear facilities for long-term safety and reliability.
오늘날 스마트홈에 대한 선호도가 높아짐에 따라 공동주택의 건축단계에서 월 패드를 도입하는 것은 선택의 요소가 아닌 필수적인 요소로 자리잡고 있다. 하 지만 스마트홈과 월패드의 편리함에도 불구하고 월패드 해킹은 주거환경에 대 한 위협요인이 되고 있다. 실제로 2021년에 한국 아파트의 월패드가 해킹당해 촬영된 영상이 다크웹에 게시되어 큰 논란이 되었다. 당시 해당 사건은 개인에 게 가장 안전하고 사적이어야 하는 영역에 대한 침해가능성에 대해 국민들로 하여금 경각심을 갖게 하는 동시에 이미 유출된 사생활 영상에 대한 보호대책 도 전무하다는 현실을 깨닫게 해주는 계기가 되었다. 한편 국내 신축 공동주택에 설치되고 있는 월패드는 주택의 기본 시설물로 인 식되고 있는 것이 현실이다. 이는 사적 생활의 유출가능성을 내포하는 월패드 설치를 입주자들이 선택할 수 없다는 점에서 월패드 보안수준의 적정성 문제 가 중요한 요소로 대두되었다. 현재 국내에서는 이러한 문제점을 해결하기 위해 월패드 보안 인증제도의 도 입과 공동주택 내 전문 기술인력의 배치를 통해 해킹 위협에 대응하고자 하고 있다. 하지만 관련 법적 규제들의 실효성을 높이기 위한 부가적인 개선안들이 제시되어야 할 시점에 와 있고, 더 나가 보안 침해 후 유출영상 보호를 위한 개인정보보호위원회의 법적 권한의 확보도 필요한 실정이다. 이에 본 연구에 서는 공동주택 월패드 보안의 기술적 개념을 고찰한 후, 국내외 월패드 보안 규제 법제 현황을 살펴보고, 이를 통해 국내 월패드 보안 관련 법제도의 방향 성에 대해 논의해 보고자 한다.
Machine learning is widely applied to various engineering fields. In structural engineering area, machine learning is generally used to predict structural responses of building structures. The aging deterioration of reinforced concrete structure affects its structural behavior. Therefore, the aging deterioration of R.C. structure should be consider to exactly predict seismic responses of the structure. In this study, the machine learning based seismic response prediction model was developed. To this end, four machine learning algorithms were employed and prediction performance of each algorithm was compared. A 3-story coupled shear wall structure was selected as an example structure for numerical simulation. Artificial ground motions were generated based on domestic site characteristics. Elastic modulus, damping ratio and density were changed to considering concrete degradation due to chloride penetration and carbonation, etc. Various intensity measures were used input parameters of the training database. Performance evaluation was performed using metrics like root mean square error, mean square error, mean absolute error, and coefficient of determination. The optimization of hyperparameters was achieved through k-fold cross-validation and grid search techniques. The analysis results show that neural networks and extreme gradient boosting algorithms present good prediction performance.
실물 크기로 제작된 L형 프리캐스트 옹벽의 저판부에 대한 휨 실험을 수행하여, 프리캐스트 부분과 현장타설 부분의 연결방법에 따른 구조적 거동을 분석하였다. 연결방법은 기존의 일반적인 철근 겹이 음 방식과 최근 새롭게 개발된 비접촉식 커플러 방식 두 가지를 적용하였다. 실험체 셋팅을 위하여 현 장타설부를 갖는 프리캐스트 L형 옹벽을 제작하여 벽체를 반력벽에 고정하고, 벽체 하단에 힌지 지점 을 설치하였다. 또한 L형 옹벽 저판부의 현장타설부 중간 지점에 하중을 재하하여 고정단 조건으로 인한 전단 및 휨이 연결부에 작용하도록 하였다. 실험결과를 보면 비접촉식 커플러를 적용한 옹벽 저 판부에서 좀더 높은 강성을 보이는 것을 확인하였으며, 최대 강도에는 차이가 없었다. 비접촉식 커플 러는 철근의 부착력에 의해 구조적 성능을 확보하는데 이를 위하여 확대마디, 연결 철근, 스파이럴바 등이 사용된다. 이러한 구성품들로 인하여 비접촉식 커플러 적용 구간에 철근 단면적 향상 효과가 나 타나 높은 강성을 갖게 된 것으로 판단 된다. 비접촉식 커플러는 기존 겹이음에 비해 이음길이를 50% 수준으로 감소할 수 있어 대형 프리캐스트 구조물의 제작에 활용되는데 이번 실험을 통하여 충분한 구조 성능을 가지고 있음을 확인하였다.
원자력 발전소에서 배관 시스템은 냉각수 및 오염수를 운반하고 생성된 증기를 터빈으로 이동시켜 에너지를 생산하는 중요한 설비이다. 국내에 건설된 원자력 발전소의 가동연수가 증가함에 따라 배관 시스템의 물리적, 기계적 성질의 열화현상은 발생할 수 있으며 이를 경년열화로 정의한다. 배관 시스 템의 경년열화는 재료의 피로, 부식(국부감육), 마모 등과 같은 메커니즘을 통해 발생할 수 있으며 재 료의 강도 및 시스템의 성능 저하와 균열을 야기할 수 있다. 지속적이고 안정적인 에너지 생산을 위해 경제성과 정확도를 고려한 원전 배관 시스템의 손상 감시 기술은 필요하다. 따라서 본 연구는 원전 배 관 시스템의 손상 감시 기술을 개발하기 위한 기초적인 연구로써 배관 시스템의 취약요소로 판단되는 elbow의 국부적인 감육에 따른 거동의 변화를 분석하고자 한다.
Code-compliant seismic design should be essentially applied to realize the so-called emulative performance of precast concrete (PC) lateral force-resisting systems, and this study developed simple procedures to design precast industrial buildings with intermediate precast bearing wall systems considering both the effect of seismic and blast loads. Seismic design provisions specified in ACI 318 and ASCE 7 can be directly adopted, for which the so-called 1.5S y condition is addressed in PC wall-to-wall and wall-to-base connections. Various coupling options were considered and addressed in the seismic design of wall-to-wall connections for the longitudinal and transverse design directions to secure optimized performance and better economic feasibility. On the other hand, two possible methods were adopted in blast analysis: 1) Equivalent static analysis (ESA) based on the simplified graphic method and 2) Incremental dynamic time-history analysis (IDTHA). The ESA is physically austere to use in practice for a typical industrial PC-bearing wall system. Still, it showed an overestimating trend in terms of the lateral deformation. The coupling action between precast wall segments appears to be inevitably required due to substantially large blast loads compared to seismic loads with increasing blast risk levels. Even with the coupled-precast shear walls, the design outcome obtained from the ESA method might not be entirely satisfactory to the drift criteria presented by the ASCE Blast Design Manual. This drawback can be overcome by addressing the IDTHA method, where all the design criteria were fully satisfied with precast shear walls’ non-coupling and group-coupling strength, where each individual or grouped shear fence was designed to possess 1.5S y for the seismic design.
The design shear strength equations of RC shear walls have been developed based on their performance under in-plane (IP) loads, thereby failing to account for the potential performance degradation of shear strength when subjected to simultaneous out-of-plane (OOP) loading. Most of the previous experimental studies on RC walls have been conducted in one direction under quasi-static conditions, and due to the difficulty in experimental planning, there is a lack of research on cyclic loading and results under multi-axial loading conditions. During an earthquake, shear walls may yield earlier than their design strength or fail unexpectedly when subjected to multi-directional forces, deviating from their intended failure mode. In this paper, nonlinear analysis in finite element models was performed based on the results of cyclic loading experiments on reinforced concrete shear walls of auxiliary buildings. To investigate the reduction trend in IP shear capacity concerning the OOP load ratio, parametric analysis was conducted using the shear wall FEM. The analysis results showed that as the magnitude of the OOP load increased, the IP strength decreased, with a more significant effect observed as the size of the opening increased. Thus, the necessity to incorporate this strength reduction as a factor for the OOP load effect in the wall design strength equation should be discussed by performing various parametric studies.
This paper presents an electrochemical immunosensor using a graphene/multi-walled carbon nanotube (MWCNT) composite platform for detecting the cardiovascular marker C-reactive protein (CRP). The immunosensor exhibited a linear detection range of 0.20–100 ng/mL CRP with a low limit of detection reaching 0.081 ng/mL. The composite material provided a 3D porous structure that allowed efficient antibody immobilization and minimized steric hindrance. The sensor showed high specificity, with minimal response to interfering substances. Using differential pulse voltammetry, the immunosensor demonstrated exceptional precision, rapid detection, and a direct correlation between CRP concentration and sensor response current. Overall, this work highlights the potential of the graphene/MWCNT composite platform as a robust tool for early CRP detection and cardiovascular disease risk assessment. The immunosensor provides sensitive and selective CRP quantification that could enable timely clinical intervention for at-risk individuals.
By developing molds and facilities to horizontally mold the functional part of the dry-cast concrete block, We intend to develop molds and a series of facilities to horizontally mold the functional part of the dry-cast concrete block to increase production per cycle while maintaining existing production methods and major facilities. In order to do so, CAE analysis is first required to develop molds and facilities for horizontally molding the functional part of the drycast concrete block in the horizontal direction. The procedure will be carried out by reviewing the validity of boundary conditions and physical properties, 3D modeling, grid generation, construction of analysis models, model validity, analysis according to frequency changes, and analysis according to physical properties. First, through the comparison of two-point support, three-point support, and two-point and three-point support in the constraint conditions, We would like to compare it with the actual molded product in the horizontal direction. But first of all, it is considered two-point support in the constraint conditions in this paper.
Recently, in newly constructed apartment buildings, the exterior wall structures have been characterized by thinness, having various openings, and a significantly low reinforcement ratio. In this study, a nonlinear finite element analysis was performed to investigate the crack damage characteristics of the exterior wall structure. The limited analysis models for a 10-story exterior wall were constructed based on the prototype apartment building, and nonlinear static analysis (push-over analysis) was performed. Based on the finite element (FE) analysis model, the parametric study was conducted to investigate the effects of various design parameters on the strength and crack width of the exterior walls. As the parameters, the vertical reinforcement ratio and horizontal reinforcement ratio of the wall, as well as the uniformly distributed longitudinal reinforcement ratio and shear reinforcement ratio of the connection beam, were addressed. The analysis results showed that the strength and deformation capacity of the prototype exterior walls were limited by the failure of the connection beam prior to the flexural yielding of the walls. Thus, the increase of wall reinforcement limitedly affected the failure modes, peak strengths, and crack damages. On the other hand, when the reinforcement ratio of the connection beams was increased, the peak strength was increased due to the increase in the load-carrying capacity of the connection beams. Further, the crack damage index decreased as the reinforcement ratio of the connection beam increased. In particular, it was more effective to increase the uniformly distributed longitudinal reinforcement ratio in the connection beams to decrease the crack damage of the coupling beams, regardless of the type of the prototype exterior walls.
The aging fishery training vessels from the past have mostly been decommissioned, and many universities are introducing state-of-the-art large fishery training vessels. The purpose of these training vessels is to train marine professionals and above all, safety to prevent marine accidents should be of utmost priority as many students embark on the vessel. This study estimated the impact of the hydrodynamic interaction forces acting on the model vessel (fishery training vessel) from the bank when the vessel pass near the semi-circle bank wall in various conditions through the numerical calculation, especially concerning maneuvering motions of the vessel. For estimation, variables were mainly set as the size of the semi-circle shape, the lateral distance between the bank and the model vessel, and the depth near the bank. As a result, it was estimated that, in order for the model vessel to safely pass the semi-circle bank wall at a speed of 4 knots, the water depth to the vessel draft ratio should be 1.5 or more (approximately 8 m of water depth), and the lateral distance from the semi-circle bank wall should be 0.4 times the model vessel’s length or more (a distance of 34 m or more). Under these conditions, it was expected that the model vessel would pass without significantly being affected by the bank wall.
In this paper, a dynamic centrifuge model test was conducted on a 24.8-meter-deep excavation consisting of a 20 m sand layer and 4.8 m bedrock, classified as S3 by Korean seismic design code KDS 17 10 00. A braced excavation wall supports the hole. From the results, the mechanism of seismically induced earth pressure was investigated, and their distribution and loading points were analyzed. During earthquake loadings, active seismic earth pressure decreases from the at-rest earth pressure since the backfill laterally expands at the movement of the wall toward the active direction. Yet, the passive seismic earth pressure increases from the at-rest earth pressure since the backfill pushes to the wall and laterally compresses at it, moving toward a passive direction and returning to the initial position. The seismic earth pressure distribution shows a half-diamond distribution in the dense sand and a uniform distribution in loose sand. The loading point of dynamic thrust corresponding with seismic earth pressure is at the center of the soil backfill. The dynamic thrust increased differently depending on the backfill's relative density and input motion type. Still, in general, the dynamic thrust increased rapidly when the maximum horizontal displacement of the wall exceeded 0.05 H%.
Background: It is well known that squat exercises are good for scoliosis patients. Especially wall facing squat (WS) is believed to be more effective than normal squat (NS). Objectives: In order to find out what effect the wall squat has on the rehabilitation exercise of patients with lumbar scoliosis compared to the conventional squat, the force between the lumbar segments was compared using a motion analysis system. Design: Quasi-experimental study. Methods: In this work, an attempt was made to provide a scientific basis for these experiences. Inverse dynamics simulations were performed for each of the 10 subjects with mild scoliosis during NS and WS using subject-specific 3D musculoskeletal models. Exercises with three sets of five cycle for NS or WS were performed. Muscle forces calculated from the simulations were compared with electromyography data for verification. Results: The imbalance of muscle forces between the right and left in erector spinae (ES) decreased with the progress of WS sets. The difference of 14.1% for the 1st set diminished to 1.8% during the 3rd set. Conclusion: The overall level of right and left ES muscle forces also increased from the 1st set to the 3rd set. The results of simulations indicated that WS was more effective than NS for scoliosis correction.
이 연구의 목적은 독일통일과정에서 통일의 기폭제 역할을 해온 ‘베를 린 장벽’(Berliner Mauer) 붕괴의 역할을 분석하면서 이를 참고로 한반 도 통일의 함의를 도출하자는 데 있다. 이 분석은 베를린 장벽의 구축으 로부터 붕괴되기까지의 과정을 네 가지 외부적 행위요인(전승4국, 3+1체 제, 고르바초프, 2+4회담)과 세 가지 국내적 행위요인(베를린 장벽, 동서 독 주민, 샤보브스키)에 초점을 두고 이들 간의 상호관계적 측면에서 비 교분석하고자 한다. 이 연구는 베를린 장벽의 붕괴가 독일통일을 이룬 단초적 선례가 되는 만큼, 통일한국에서도 비무장지대(DMZ)의 역할이 무엇인지도 동시에 고찰한다. 즉 독일통일과정이 동서독 당국 간의 정상 회담이나 협상 차원만은 아니었듯이, 우리도 남북한 통일을 위해서는 베 를린 장벽 붕괴의 역할을 해낸 통일독일 사례처럼 DMZ 문제에 있어 이 를 벤치마킹할 필요성이 있다.
본 연구는 수직 벽체형 콘크리트 구조물의 정밀안전진단을 위한 외관조사시 고품질 정밀영상을 자동화된 방식으로 획득하여 균열손상을 탐지하고 시설물의 상태를 평가하기 위하여 개발된 등벽드론 탑재형 균열진단 시스템에 대한 것이다. 본 논문에서는 영상기반 균열진단 시스템을 이용한 정밀영상 획득기술, 자동화된 영상처리 알고리즘을 이용한 데이터 처리 기법을 제시하였으며, 실험적으로 도출된 지상표본거리를 기반으로 영상처리 자동화 알고리즘을 이용하여 생성된 균열모사 시험벽체의 평면전개 이미지 상 균열손상의 위치 정확도를 평가 분석하였다. 평가분석 결과, 가로축 길이 대비 최대 1.1%, 세로축 길이 대 비 최대 1.4%의 오차율을 보이는 것으로 나타났다. 제안된 영상 내 픽셀 좌표와 지상표본거리를 기반으로 균열손상의 위치를 추정하는 기법은 실측 좌표 대비 평균 1.0% 이하의 위치 오차를 가지는 것으로 평가되었다. 최종적으로 영상기반 진단과 긴급 보수와 같은 일반적인 시설물의 유지관리에 요구되는 위치 정확도를 확보하고 있는 것으로 분석되었다.