검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 270

        21.
        2022.10 구독 인증기관·개인회원 무료
        For deep geological repository of the spent nuclear fuel, the fuel assemblies loaded in the storage cask are transferred to the disposal cask and the operation is performed in the fuel handling hot cell at the fuel re-packaging facility. As the fuel handling hot cell shielding is accomplished by the concrete wall and the viewing glass window, the required shielding thickness was evaluated for both materials. The ordinary concrete is applied to hot cell wall and two kinds of glasses, i.e., single layer of lead glass and double layer of lead glass and borosilicate glass, are considered for the viewing glass window. A bare spent PWR fuel assembly exposed to the environment in the hot cell was considered as the neutron and gamma radiation sources. The neutron and gamma transport calculations were performed using the MAVRIC program of the SCALE code system for the dose rate evaluation. The dose limit of 10 μSv/h is applied as the target dose to establish the required shielding thickness. The concrete wall of 94 cm thickness reduces the total dose rate to 6.9 μSv/h, which is the sum of neutron dose and gamma dose. Penetrating the concrete wall, both of the neutron dose and the gamma dose decrease constantly with shield thickness and the gamma dose is always dominant through whole penetrating distance. Single layer lead glass of 74 cm thickness reduces total dose rate to 6.2 μSv/h. Applying double layer shield glass combined of lead glass and borosilicate glass, the total dose rate reduces to 3.6 μSv/h at same shield thickness of 74 cm. Through the shield glass, gamma dose decreases rapidly and neutron dose decreases slowly compared with those for concrete wall. In result, neuron dose becomes dominant on the window glass shielding. The more efficient dose reduction of double layer glass is achieved by the borosilicate glass’s superior neutron shielding power. Thus, the use of double layer glass of lead glass and borosilicate glass is recommended for the viewing glass of the fuel handling hot cell. Finally, it is concluded that about 1 m thick concrete wall and 75 cm thick viewing glass window are sufficient for the radiation shielding of the hot cell at the spent fuel repackaging facility.
        22.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: The craniocervical flexion test (CCFT) was developed for the activation and endurance of deep cervical flexors. However, the muscle thickness and muscle thickness changing ratio of the sternocleidomastoid (SCM) and deep cervical flexor (DCF) muscles in subjects with and without forward head posture (FHP) have not been reported. Objects: To determine the difference in thickness of the SCM and DCF muscles and the difference in the muscle thickness changing ratio between SCM, DCF, and DCF/SCM 20 mmHg and DCF/SCM 30 mmHg between subjects with and without FHP. Methods: Thirty subjects with and without FHP were enrolled. The muscle thickness of the SCM and DCF was measured when maintained at a baseline pressure of 20 mmHg and a maximum pressure of 30 mmHg using a pressure biofeedback unit during the CCFT. Ultrasonography was used to capture images of SCM and DCF muscle thickness during the CCFT, which was calculated using the picture archiving and communication system (PACS). Results: We observed a significant difference within the pressure main effect between SCM and DCF at a baseline pressure of 20 mmHg and a maximum pressure of 30 mmHg (p < 0.05). However, there was no significant difference in the muscle thickness and muscle thickness changing ratio for SCM and DCF during CCFT between subjects with and without FHP. Conclusion: There was no significant difference in the muscle thickness recruitment pattern during CCFT in posture changes between subjects with and without FHP.
        4,000원
        23.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the demand for appropriate heat dissipation measures to improve product stability and performance continues to increase and product design becomes highly integrated, research to improve heat transfer performance while maintaining the same area or size is required. In this study, the sample-shaped aluminum plate was treated as upper-coating, and the thickness of the coating was divided into 1mm, 2mm, and 3mm, respectively, and the coating material was applied with silver, copper, and graphene. The temperature condition of the heat source was set to 473K, and heat dissipation analysis was performed under natural convection. The thermal performance was compared and analyzed through temperature distribution, flow velocity distribution, and heat flux, and it was confirmed that the high thermal conductivity of graphene compared to other materials had a dominant effect on the increase in the conduction heat transfer rate. And it was confirmed that the high surface temperature of the graphene coating also increased the heat transfer rate by convection, thereby enhancing the heat dissipation effect.
        4,000원
        24.
        2022.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: The superimposed technique (ST) involves the application of electrical muscle stimulation (EMS) during voluntary muscle action. The physiological effects attributed to each stimulus may be accumulated by the ST. Although various EMS devices for the quadriceps muscle are being marketed to the general public, there is still a lack of research on whether ST training can provide significant advantages for improving quadriceps muscle strength or thickness compared with EMS alone. Objective: To compare the effects of eight weeks of ST and EMS on the thicknesses of the rectus femoris (RF) and vastus intermedius (VI) muscles and knee extension strength. Methods: Thirty healthy subjects were recruited and randomly assigned to either the ST or EMS groups. The participants underwent ST or EMS training for eight weeks. In all participants, the thicknesses of the RF and VI muscles were measured before and after the 8-week intervention by ultrasonography, and quadriceps muscle strength was measured using the Smart KEMA tension sensor (KOREATECH Co., Ltd.). Results: There were significant differences in the pre- and post-intervention thicknesses of the RF and VI muscles as well as the quadriceps muscle strength in both groups (p < 0.05). RF thickness was significantly greater in the ST group (F = 4.294, p = 0.048), but there was no significant difference in VI thickness (F = 0.234, p = 0.632) or knee extension strength (F = 0.775, p = 0.386). Conclusion: EMS can be used to improve quadriceps muscle strength and RF and VI muscle thickness, and ST can be used to improve RF thickness in the context of athletic training and fitness.
        4,000원
        25.
        2022.05 구독 인증기관·개인회원 무료
        The Co-60 is a radioactive material widely used in domestic and foreign medical, industrial, health and research fields. Currently, world market for the Co-60 is about 80 MCi/yr and is expected to grow to 150 MCi/yr by 2025. For the Co-60, Nordion of Canada occupies about 80% of the world market. In the case of Korea, a small amount of sources with relatively low radioactivity intensity are produced using research reactors, but most of the Co-60 is entirely dependent on imports. Accordingly, although the technical feasibility of the Co-60 production technology using the PHWR was evaluated, it was evaluated as a negative result on the additional construction of a hot cell, core management, safety analysis and economic feasibility. Canada, the main producer of the Co-60, is also conducting research on the Co-60 production technology using PWR with GE-Hitachi and Westinghouse as the number of PHWR is expected to decrease. In Korea, it is necessary to preoccupy the Co-60 production technology and auxiliary technology using the PWR by utilizing excellent technology, and active research is being conducted to secure unique nuclear power technology that does not depend on foreign countries. Therefore, in this study, the thickness and weight of the radioactive shielding required for handling (transport) of Co-60 produced using the PWR were calculated.
        26.
        2022.05 구독 인증기관·개인회원 무료
        The spent filters stored in Kori Unit 1 are planned that compressed and disposed for volume reduction. However, shielding reinforcement is required to package high-dose spent filters in a 200 L drum. So, in this study suggests a shielding thickness that can satisfy the surface dose criteria of 10 mSv·h−1 when packaging several compressed spent filters into 200 L drums, and the number of drums required for the compressed spent filter packaging was calculated. In this study, representative gamma-emitting nuclides in spent filter are assumed that Co-60 and Cs-137, and dose reduction due to half-life is not considered, because the date of occurrence and nuclide information of the stored spent filter are not accurate. The shielding material is assumed to be concrete, and the thickness of the shielding is assumed to 18 cm considering the diameter of the spent filter and compression mold. Considering the height of the compressed spent filter and the internal height of the shielding drum, assuming the placement of the compressed spent filter in the drum in the vertical direction only, the maximum number of packaging of the compressed spent filter is 3. When applying a 18 cm thick concrete shield, the maximum dose of the spent filter can packaged in the drum is 125 mSv·h−1, so when packaging 3 spent filters of the same dose, the dose of a spent filter shall not exceed 41 mSv·h−1 and not exceed 62 mSv·h−1when packing 2 spent filters. Therefore, the dose ranges of spent filters that can be packaged in a drum are classified into three groups: 0–41 mSv·h−1, 41–62 mSv·h−1, and 62–125 mSv·h−1based on 41 mSv·h−1, 62 mSv·h−1, and 125 mSv·h−1. When 227 spent filters stored in the filter room are classified according to the above dose group, 207, 3 and 4 spent filters are distributed in each group, and the number of shielding drums required to pack the appropriate number of spent filters in each dose group is 75. Meanwhile, 8 spent filters exceeding 125 mSv·h−1 and 5 spent filters that has without dose information are excluded from compression and packaging until the treatment and disposal method are prepared. In the future, we will segmentation of waste filter dose groups through the consideration of dose reduction and horizontal placement of compressed spent filters, and derive the minimum number of drums required for compressed spent filter packaging.
        27.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 육계사육에서 횃대의 제공효과와 최적 두께를 구명하기 위해 진행하였다. 12일령 육계(RossⅹRoss) 288수를 24개의 독립된 공간(7.3 수/m2)에 균등한 평균 체중으로 분배하여 42일령까지 사양실험을 실시하였다. 그룹은 일반 평사사육(대조구)과 3개의 횃대 처리구(두께: 3, 4 및 5 cm)인 총 4개로 구성하였으며, 각 그룹은 6반복과 반복당 12수씩으로 배치하였다. 각 반복 별로 횃대의 길이는 1.3 m (0.11 m/수)로서 높이 15 cm에 설치하였다. 조사항목으로 육계의 생산성, footpad dermatitis (FPD)과 hock burn (HB) 지표 및 횃대이용성을 확인하였다. 본 연구결과, 육계사육에서 횃대의 유무와 두께에 따른 체중, 증체량, 사료섭취량 및 사료요구율은 통계적 차이가 없었다. FPD는 처리구 간 유의적 차이가 없었으나, HB 지표는 4와 5 cm의 횃대를 제공한 처리구에서 일반 평사와 3 cm 두께의 횃대에서 사육한 육계에 비해 개선되었다(p<0.05). 육계가 횃대를 이용한 시간은 사육전기(12~24일령)에는 차이가 없었으나, 사육후기(25~42일령)에 횃대를 이용한 총 시간은 5 cm 두께에서 3과 4 cm 두께보다 높았으며(p<0.05), 올라간 횟수에 비해서도 더 많은 시간을 보냈다(p<0.05). 그러므로 횃대는 육계의 다리질병을 줄이며, 4~5 cm의 두께를 이용하는 것이 가장 적합할 것으로 사료된다.
        4,000원
        29.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to evaluate the effect of pork belly thickness on physicochemical and sensory characteristics after pan frying. Pork belly with three different thickness (5, 10, 20 mm) from three different parts (A:thoracic vertebrae no. 5-9, B:thoracic vertebrae 10-14, C:lumbar vertebrae 1-6) was pan grilled with electronic grill until it reached an internal temperature of 71℃. Cooking loss, shear force, sensory characteristics, volatile compounds of cooked pork belly were determined. Electric nose analysis was performed to support descriptive analysis and consumer sensory analysis. The cooking loss of pork belly with 20 mm thickness from all positions was significantly low (p<0.05). Shear force increased with increase in thickness (p<0.05). Electric nose identified major seven volatile compounds such as acetonitrile, (Z)-4-heptenal, 2-octanol, linalool, carbon disulfide, methylcyclohexane, n-nonanal to discriminate those samples. The part of pork belly significantly affected the intensity of volatile compounds rather than thickness. In discriminate analysis, the overall acceptability of pork belly (A and B parts) with 20 mm thickness was higher than that of pork belly with 5 mm thickness. In addition, the overall acceptability by consumers for pork belly with 20 mm thickness from A, B, and C parts was higher than the overall acceptability for pork belly with 5 mm thickness. This preliminary study suggests that it is more desirable to use pork belly with 20 mm thickness from part A when cooking on a pan gril compared with pork belly of 10 mm or 20 mm thickness from part B or C in the meat markets and restaurant.
        4,500원
        30.
        2022.02 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Purpose: 본 연구의 목적은 4주기간동안 횡격막 호흡을 적용한 기구 필라테스 운동이 20대 성인의 유연성, 복부 근 두께, 근육량, 체지방, 호흡에 미치는 영향에 대해 알아보고자 하는 것이다. Methods: 근골격계 질환이 없는 대상자 35명을 대상으로 수행하였으며, 횡격막 호흡을 하는 그룹과 횡격막 호흡을 하지 않는 그룹으로 나누었으며, 두 그룹 모두 필라테스를 수행하였다. 실험에 사용한 기기로는 Ultrasonography(US), Pulmonary function tests(FEV1 / FVC), Bioeletic Impedance Analysis, Sit and reach test를 사용하였다. 정규성 검증을 실시한 후, 반복측정분산분석 (repeated measures of ANOVA)를 사용하여 운동 전, 호흡을 적용한 운동, 호흡 비적용 운동을 비교하였다. 사후 분석을 위해 Fisher’s LSD를 실시하였다. Results: 필라테스 운동은 복근의 두께와 유연성에 긍정적인 영향을 미쳤습니다. SaR test는 운동 전과 호흡을 적용한 운동과 호흡을 적용하지 않은 운동 사이에 유의한 유의성을 보였다(P <0.05). 근육두께 측정 TRA, EO, IO 모두 운동 전보다 호흡 적용 운동과 비호흡 운동에서 유의한 차이가 있었고(P <0.05), TRA와 IO에서는 추가 시간 사이에 유의한 차이가 없었다. 호흡하지 않는 운동(P >0.05). 그러나 EO에서는 호흡운동을 추가한 시간과 호흡운동을 하지 않은 시간 사이에 유의한 차이가 있었다( P <0.05). Conlusion: 결론적으로, 횡격막 호흡을 이용한 필라테스 운동과 횡격막 호흡이 없는 필라테스 운동은 복근의 두께와 유연성에 긍정적인 영향을 미치는 것으로 나타났다. 그러나 횡격막 호흡과 비횡격막 호흡 사이에는 큰 차이가 없었다.
        4,000원
        31.
        2022.02 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Purpose: 본 연구의 목적은 본 연구의 목적은 2주간의 회전근개의 강화운동이 회전근개의 근육 두께, 견봉하 공간, 어깨 불안정성에 미치는 영향을 알아보고자 하는 것이다. Methods: 근골격계 질환이 없는 대상자 35명을 대상으로 수행하였으며, 횡격막 호흡을 하는 그룹과 횡격막 호흡을 하지 않는 그룹으로 나누었으며, 두 그룹 모두 필라테스를 수행하였다. 실험에 사용한 기기로는 Ultrasonography(US), Pulmonary function tests(FEV1 / FVC), Bioeletic Impedance Analysis, Sit and reach test를 사용하였다. 근골격계 질환이 없는 대상자 20명이 실험에 참여하였다. 근력 강화 운동은 2주 동안 주 5세트, 총 50세트 실시하였으며, 운동은 풀캔, 빈캔, 외회전 운동으로 진행하였다. 초음파를 이용하여 극상근과 극하근의 근육 두께와 견봉하 공간의 변화를 확인하였다. CSMI는 가시위근과 가시아래근의 근력을 평가하는 데 사용되었다. 정규성 검증을 실시한 후, 반복측정분산분석 (repeated measures of ANOVA)를 사용하여 운동 전, 1주후, 2주후를 비교하였다. 사후 분석을 위해 Fisher’s LSD를 실시하였다. Results: 근력의 비교에서 운동 2주 후 측정 시 내회전에서 유의한 차이가 있었다 (P <0.05). 외회전에서는 유의한 차이가 없었다 (P >0.05). 근육두께에서는 가시위근과 가시아래근의 근육 두께는 유의한 차이가 없었다 (P >0.05). 또한 봉우리밑 공간에서도 유의한 차이가 없었다 (P >0.05). Conlusion: 결론적으로, 빈캔 운동과 풀캔 운동, 측면 외회전 운동은 어깨관절 안쪽돌림의 근력 강화에 긍정적인 효과가 있었다
        4,000원
        32.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: To restore the trunk function of stroke patients who tend to experience trunk weakness, a single exercise intervention is usually applied. However, problems with the trunk remain even after such an intervention. To overcome this challenge, combining other intervention methods with an exercise is suggested during training. Objectives: To investigate the effect of breathing based abdominal draw-in technique on the thickness of the transversus abdominis muscle and trunk control in stroke patients. Design: Randomized controlled study. Methods: After designating a group that will perform the abdominal draw-in technique as Experimental Group I and another group that will perform the breathing based abdominal draw-in technique as Experimental Group II, the thickness of the transversus abdominis muscle and the trunk impairment scale (TIS) of the subjects were measured as pre-tests before the interventions and as post-tests after the six week intervention period. Results: In the within group comparison, there was a significant change in the thickness of the transversus abdominis muscle for both groups while the subjects performed the abdominal draw-in technique; a significant change was also noted in their TIS (P<.05) (P<.01). However, in the inter-group comparison, a significant difference was found only in the TIS between the two groups (P<.05). Conclusion: After the application of the breathing based abdominal draw-in technique, an efficient contractile response was observed even in the muscles around the abdomen of the subjects, which indicates that this technique is an intervention method that can more effectively improve trunk control.
        4,000원
        33.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 구조물의 좌굴 온도와 좌굴 형상을 제어하는 새로운 크기 최적화 방법에 대해서 소개한다. 구조적 안정성 관점에서 구조물의 좌굴 온도와 좌굴 형상을 예측하는 것은 중요한 주제 중 하나이다. 이를 공학적인 직관을 통해 예측하고 최적화된 구조 설계 를 하는 것은 너무나 어려운 과제이다. 이러한 한계점을 해결하기 위해 본 연구에서는 유한요소 시뮬레이션과 치수 최적 설계 방식의 조합을 제안한다. 구조물의 좌굴 온도와 좌굴 형상이 구조물의 두께에 영향을 받는다는 생각에서 착안해 설계 변수를 구조물의 노드 의 두께 값으로 설정했다. 좌굴 온도 값과 좌굴 형상을 목적 함수로 정해진 부피 값을 제약 조건으로 두었다. 치수 최적 설계를 통해 원 하는 좌굴 온도와 좌굴 형상을 유도하기 위한 최적의 두께 분포를 결정할 수 있다. 제안된 치수 최적 설계의 타당성은 본 논문의 다양 한 직사각형 복합 구조물 예제들을 사용해서 검증하였다.
        4,000원
        34.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the types of thermal breakers applied to structures to prevent thermal bridges were identified. Condensation prevention performance was evaluated for apartment houses with standard floor structures to which a thermal breaker was applied. In addition, the effect of thermal cross-blocking was compared by calculating the total heat and equivalent U-value through the wall. (1) As a result of the evaluation of anti-condensation performance, when “가” grade insulation was applied, the surface temperature increased by about 1K due to the application of the thermal breaker. The TDR value increased by about 0.06 to 0.07. When "나" grade insulation was applied, the minimum surface temperature increased by about 1K, and the TDR value increased by about 0.05~0.06. (2) As a result of the evaluation of total heat and U-equivalent, it was possible to reduce the total heat by 38.5~44.9% and U-equivalent by 38.5~45.0% for the "가" grade insulation to which the thermal breaker was applied. In addition, the "나" grade insulation to which the thermal breaker was applied can reduce total heat by 38.9 to 43.6%, and reduce the Uequivalent by 38.9 to 43.7%.
        4,000원
        37.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: Previous studies have been reported that when instrument assisted soft tissue mobilization (IASTM) and the self-myofascial release technique were used on the muscles. However, studies that applied the IASTM and self-stretching to the gastrocnemius muscle are thought to be necessary but there is no such previous study. Objectives: To investigate the effects of IASTM and self-stretching on gastrocnemius muscle thickness and the range of motion of joint in dorsiflexion in healthy college student. Design: Quasi-experimental design (single blind). Methods: The subjects were healthy college students in their 20s with a healthy body. As for the experimental method in this study, comparison between before and after the experiment was performed to compare the effects of myofascial release using IASTM and stretching. The preliminary survey investigated the range of motion (ROM) of ankle joint of the subjects. The thicknesses of gastrocnemius muscles were measured using ultrasonography. One day after the preliminary survey, IASTM interventions and self-stretching interventions were randomly selected. If IASTM intervention is selected, the IASTM of the gastrocnemius muscle was applied for 5 minutes. After than, muscle thickness and the ankle dorsiflexion ROM were measured. Subjects were asked to take a break for about one day after performing the intervention. Self-stretching was applied to the gastrocnemius muscle for 5 minutes identically. After than, muscle thickness and the ankle dorsiflexion ROM were measured. Results: The thickness of the gastrocnemius muscle decreased significantly IASTM intervention, and the ankle dorsiflexion ROM increased significantly IASTM intervention. Ankle dorsiflexion ROM increased significantly the selfstretching intervention. The amounts of change in ankle dorsiflexion ROM through the IASTM was significantly greater than that through self-stretching. Conclusion: In order to immediately increase muscle flexibility in a short time, the IASTM is more effective although the self-stretching method is also effective.
        4,000원
        38.
        2021.07 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Various surface colors are predicted and implemented using the interference color generated by controlling the thickness of nano-level diamond like carbon (DLC) thin film. Samples having thicknesses of up to 385 nm and various interference colors are prepared using a single crystal silicon (100) substrate with changing processing times at low temperature by plasma-enhanced chemical vapor deposition. The thickness, surface roughness, color, phases, and anti-scratch performance under each condition are analyzed using a scanning electron microscope, colorimeter, micro-Raman device, and scratch tester. Coating with the same uniformity as the surface roughness of the substrate is possible over the entire experimental thickness range, and more than five different colors are implemented at this time. The color matched with the color predicted by the model, assuming only the reflection mode of the thin film. All the DLC thin films show constant D/G peak fraction without significant change, and have anti-scratch values of about 19 N. The results indicate the possibility that nano-level DLC thin films with various interference colors can be applied to exterior materials of actual mobile devices.
        4,000원
        39.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: Patients with dysphagia after stroke are treated with neuromuscular electrical stimulation (NMES), but its effect on masseter muscle thickness and bite force in the oral phase is not well known. Objectives: To investigated the effect of NMES on masseter muscle thickness and occlusal force in patients with dysphagia after stroke. Design: Two group, pre-post design. Methods: In this study, 25 patients with dysphagia after stroke were recruited and allocated to either the experimental or the control groups. Patients in the experimental group were treated with NMES to the masseter muscle at the motor level for 30 minutes and were additionally treated with traditional swallowing rehabilitation for 30 minutes. In contrast, patients in the control group were only treated with traditional swallowing rehabilitation for 30 minutes. Masseter muscle thickness was measured using ultrasonography before and after intervention, and bite force was measured using an bite force meter. Results: The experimental group showed significant improvement in masseter muscle thickness and bite force compared to the control group. Conclusion: NMES combined with traditional dysphagia rehabilitation is effective in improving masseter muscle thickness and bite force in patients with dysphagia after stroke.
        4,000원
        1 2 3 4 5