Recently, in newly constructed apartment buildings, the exterior wall structures have been characterized by thinness, having various openings, and a significantly low reinforcement ratio. In this study, a nonlinear finite element analysis was performed to investigate the crack damage characteristics of the exterior wall structure. The limited analysis models for a 10-story exterior wall were constructed based on the prototype apartment building, and nonlinear static analysis (push-over analysis) was performed. Based on the finite element (FE) analysis model, the parametric study was conducted to investigate the effects of various design parameters on the strength and crack width of the exterior walls. As the parameters, the vertical reinforcement ratio and horizontal reinforcement ratio of the wall, as well as the uniformly distributed longitudinal reinforcement ratio and shear reinforcement ratio of the connection beam, were addressed. The analysis results showed that the strength and deformation capacity of the prototype exterior walls were limited by the failure of the connection beam prior to the flexural yielding of the walls. Thus, the increase of wall reinforcement limitedly affected the failure modes, peak strengths, and crack damages. On the other hand, when the reinforcement ratio of the connection beams was increased, the peak strength was increased due to the increase in the load-carrying capacity of the connection beams. Further, the crack damage index decreased as the reinforcement ratio of the connection beam increased. In particular, it was more effective to increase the uniformly distributed longitudinal reinforcement ratio in the connection beams to decrease the crack damage of the coupling beams, regardless of the type of the prototype exterior walls.
In this study, two ventilation holes were considered to prevent condensation in the circular column supporting the provision crane on a training ship(Saenuri) for Mokpo National Maritime University. The ventilation holes could be understood as the most simple and inexpensive way to prevent condensation because it was formed only by drilling. If sufficient ventilation is provided, the insulation and corrosion of an electric motor can be improved, and a comfortable state can be ensured in the circular column. The circular column had an electric motor for driving the provision crane so that the basic principle was to utilize the kinetic energy for the flow field from a cooling fan in the circular column. The ventilation holes attenuated the low-velocity area in the circular column and contributed to internal flow circulation with updrafts. The results were discussed through numerical analysis based on computational fluid dynamics.
본 연구는 서울시에 조성되어 있는 수직정원공간의 경관적 이미지를 파악하고 향후 수직정원 을 효과적으로 유지하기 위해서 어떠한 변수 들이 중요한 역할을 하는지를 확인하기 위한 목적 으로 수행되었다. 대상은 네이처리퍼블릭 명동유네스코점과 돈의문박물관마을 외벽의 수직정 원이고 네이버 설문조사 툴을 이용하여 조사를 시행하였다. 분석기법은 기술통계분석과 인자 분석 및 다중회귀분석을 실시하였다. 네이처리퍼블릭 명동점 전면부 수직정원에 대한 시각적 이미지 평가는 깨끗하고 아름다우며 흥미로운 공간이미지를 구축하고 있는 것으로 파악되었 다 ‘신비로운-신비롭지 않은’, ‘연속적인-단절된’ 등의 변인은 상대적으로 낮은 평가치를 보이 고 있는 바 이는 명동 한복판의 독립된 사각형 건물로 인한 영향으로 생각된다. 돈의문박물관 마을 수직정원은 특이하고 아름다운 경관으로 인지됨을 볼 수 있다. 반면 ‘높은-낮은’, ‘넓은- 좁은’, ‘정돈된-정돈되지 않은’ 등의 변인은 다소 부정적 의미의 평가를 받았다. 모두 4개의 인 자군으로 공간이미지가 함축되어 분석되었고 전체 변량 중 이들 인자군의 설명력은 69.88%였 으며 30.20%는 오차변량과 특수변량이라 볼 수 있다. 인자분석 결과를 토대로 수직정원의 시각 적 이미지를 설명하는 인자를 ‘특이성인자’, ‘자연성인자’, ‘정연성인자’, ‘개방성인자’ 등 4개로 분류하였다. 수직정원 경관에 대한 시각선호에 가장 영향을 높게 미치는 변인은 자연성인자 및 정연성인자로 나타나 수직정원의 전반적인 경관이미지가 자연적 아름다움에 의해 좌우되고 있 음을 보여주고 있다.
The domestic of modern architectural remodeling method emphasizes simple aesthetic elements, and the correct design and construction methods are not established based on quantitative grounds, thus damaging the value of cultural properties. This study attempts to re-examine the value of modern buildings recognized as old buildings. It is a basic step to present the correct remodeling of the building. The design criteria for exterior wall remodeling of modern buildings were presented. These research results are suitable for energy conservation design standards and can prevent defects in buildings. In the future, more accurate analysis will be required by securing physical property values for various domestic materials through subsequent research.
The office building more than 3,000㎡ of the total floor area should be needed to improve the energy efficiency based on government's recommendation. In this study, the new composite panel with structural function is conducted to check the thermal conductivity for application of exterior wall. The thermal transmittance was calculated by dynamic analysis to consider the thickness of insulation only per locations based on design criteria. The simulation program for the analysis was used TRISCO Radcon module, which has a function of a steady-state 3-dimensional heat transfer analysis.
최근 10여년간 공동주택 하자보수를 둘러싼 기획소송이 전국적으로 확산되면서 전체 이행 청구 금액이 4,700억원을 넘어서고 있으며, 특히 일부 법무법인이나 하자진단업체가 주도 하는 기획소송 상당수가 보수보다는 손해배상에 초점을 맞추고 있어, 이해 관계자들의 갈 등과 건설사 피해, 그리고 장기적으로는 시공비용 및 분양가 상승으로 연결될 수 있으며, 정작 하자보수를 적기에 할 수 없어 입주자의 불만이 높아가고 있다. 공동주택의 하자 중 외벽도장의 하자를 판정할 수 있는 기준이 애매함으로 하자판정기준의 부재는 입주자와 시 공회사간의 의견대립과 소송증가를 초래하고, 법원감정인의 주관적인 판단에 의한 감정금 액 산출과 법원의 보수공사비 판결로 이어지는 문제로 나타나고 있어, 공동주택의 외벽도 장 기준마련이 시급한 상태이므로 좀 더 심도 있는 연구를 통하여 체계적이고 합리적인 방 안을 마련하고자 한다.
하자보수 판결금액은 실 보수 금액보다 과다하게 판결되고, 하자소송이 증가하는 원인이었 다는 것을 알 수 있다. 이상과 같이 외벽도장공사로 인한 하자소송의 소모적인 분쟁과 사 회적인 낭비를 줄이기 위해선, 관계법령에 외벽도색 기준의 명문화가 시급하여 다음과 같 이 제안하고자 한다.
첫째 전체보수비 중 균열보수비는 63.02%와 외벽도색 공사비가 32.14%로 높은 비중을 차 지하고 있다. 도장하자보수비는 도장공사의 부적합시공에 의한 하자보다 콘크리트 구조체 의 균열발생에 따라 균열 보수 후 미관상, 심미적인 면을 보완하는 방법으로 도장공사를 실시하고 있다. 공동주택의 외벽도장은 부분도장과 전체도장으로 구분하며, 도장횟수와 고 소할증에 따라 감정인마다 많은 차이를 보이고 있다. 외벽 균열보수 후 벽면도장은 일반 적으로 균열로 인한 부분도장 면적이 8.0% 이상일 경우 전체도장을 하며, 미만인 경우 부 분도장으로 적용 한다.
둘째 공동주택 외벽도장 하자보수 판결 66건 중 감정인이 산정한 부분도장은 27건으로 42.85%이며, 전체도장 중 1회 도장 29건으로 46.03%, 2회 도장 7건으로 11.11%로 전체도장 이 57.15%이다. 대체적으로 60~90% 판결이 전체의 80%정도이며, 80%의 판결이 30.3% 로 가장 높기에 이를 적용 한다.
셋째 공동주택 외벽 도장공사는 건설표준품셈에 고소작업시 노임할증을 공통사항에 적용 하는 방법과 건축공사 도장공사에 적용하는 방법이 있으나, 외벽도장 공사의 구체적인 기 준이 없는 관계로 감정인은 2015년도 서울중앙지방법원 감정실무 기준을 적용하나, 지나치 게 과다하게 산정되어 현실성이 떨어져 많은 불만을 갖는 관계로 실제 공사시 전문업체의 작업능률에 따른 노임할증을 고려하여 25층일 경우 15% 가산을 적용 한다. 넷째 균열보수후 부분도장만 실시할 경우에는 2회 도장 30㎝로 하며, 전체도장을 실시할 경우에는 도장공사비의 60%는 건설회사, 40%는 입주자가 부담하는 것을 제안하고자 한다.
This paper presents the experimental results of a Soil-Cement Composite Earth Retaining Wall comprised of reinforced concrete underground wall, H-shaped steel beams in earth retaining wall and fiber reinforced soil cement wall. Sixteen specimens are tested to evaluate the bending capacity of the wall. Main variables in the test are strength of concrete, arrangement of shear connector, soil-cement, and fiber reinforcement. Test results are as follows. (1) Composite member under positive moment showed 18% increase of the maximum strength. (2) After soil cement was reinforced with fiber by adding 1% of soil cement weight, compared to cases not reinforced with fiber, strength of under compression increased 7%, moreover, 30% of strength enhancement was shown under tension case also. (3) When the composite member resists positive bending moment (i.e., H-shaped steel beam is in compression), the strength is increased by 18%. Moreover, 7% additional strength enhancement appears after the soil cement is reinforced by fiber. As a results, fiber reinforced soil cement has strength enhancement effect up to 25%.
본 연구에서는 건설 구조물에 사용되는 건설 자재 중 콘크리트 구조체에 전면 부착 시공되어 건축물의 내외부로부터 스며들거나 넘쳐흐르는 물을 막을 수 있는 차단마감재인 방수재료에 있어 가속 환경 조건 속의 지하 외벽에서의 방수 성능 설계의 일환으로 내진 성능 설계 가능성을 제안하고 그 품질검증 시험방법에 대해 검토하였다. 국내외 건설자재 내진설계 현황을 살펴보았을 때, 국내의 경우 아직까지 현행법상 건축 과정에서의 내진설계 규제는 있지만 자재에 대한 규제는 없어 내진용 제품군이 드물고 대부분 시공법에 의존하고 있는 상황이다. 국외의 경우 일본, 캐나다, 독일과 같이 비구조재에 내진성능을 부여한 다양한 건축자재가 개발되고 있음을 확일 할 수 있었고, 이러한 내진설계 개념은 앞장에서 살펴본 바와 같이, 지하 콘크리트 구조체에 전면접착 혹은 부분 부착되어 시공되는 선행 외방수재료에 있어 지진에 대한 보완 대응력을 가질 수 있다면 내진 설계된 구조체와 함께 누수 예방 및 방지 기술로서 그 적용성을 기대할 수 있을 것으로 판단된다.
This paper presents a rope modeling and verification for the robotic platform of the wall cleaning robot (ROPE RIDE). ROPE RIDE has the characteristics of climbing up and down using a rope fixed on the roof like traditional workers. In order to perform a stable operation with a wall cleaning robot, it is necessary to estimate the position of the robot in a vertical direction. However, due to the high coefficient of extension and nonlinearity of the climbing rope, it is difficult to predict the behavior of the rope. Thus, in this paper, the mathematical modeling of the rope was carried out through the preliminary experiment. Extensive experiments using different types of rope were used to determine the parameters of the constitutive equation of climbing ropes. The validity of the determined parameters of various ropes was verified through the experiment results.
This study developed a consecutive convexo-concave shaped shear reinforcement approach as an alternative for transverse crossties in basement walls. Test results revealed that the developed shear reinforcement is more favorable to restricting the opening of the inclined cracks and enhancing the shear capacity of the basement wall when compared with the conventional crossties.
콘크리트 구조물이 점차 대형화, 고층화됨에 따라 지하구조물이 증가하고 있으며 지하실, 지하상가, 지하주차장, 지하철 등 그 종류 또한 다양해지고 있다. 이에 따라 지하구조물에 사용된 방수공법으로는 아스팔트계, 가황고무계, 점착형 시트재 등의 시트계 방수재를 이용한 외 방수공법을 주로 사용하였으나, 조인트 부분, 균열 발생 시 방수층의 파단 등 시트 방수공법의 문제점이 나타나 최근 방수층이나 외벽방수 의 품질 확보와 구조물 거동에 대한 하자 발생률을 줄이고자 아스팔트 씰과 아스팔트 방수시트를 복합으로 사용하는 복합공법이 널리 사용되 어 지고 있다. 그러나 일부 민간 건설 현장에서 아스팔트 씰의 누유현장으로 매스컴에 오르내리면서 아스팔트 씰의 적정품질 확보가 중요시되 는 시점이다. 이에 본 연구에서는 국내에서 사용되고 있는 아스팔트 씰계 제품을 대상으로 옥외 수직부 흘러내림 특성을 평가하였다.
This study focus on Perimeter Concrete Wall Dampers (PCWD). PCWD can achieve required large mass ratio without additional mass. This system also can control multimode vibration. Suitable location for the installation of PCWD and their tuning frequencies are selected based on modal parameters of the uncontrolled structure respectively. In addition to the numerical simulation, an eleven story is modeled using SAP2000. The proposed system is greatly reducing seismic response of main structure.
Typically low-rise dormitory designed bearing wall system. So, insulated concrete sandwich panel for the application of a rigid frame structure was changed. This study presents field application of insulated concrete sandwich panel through applying Test-Bed.
Construction period is one of the most important factors which influence on cost and quality in nuclear power plant construction. As part of continued efforts for the competent reactor type, the construction improvements such as application of mechanical rebar splice, optimum lift height for concrete placement and enlargement of liner plate module in the reactor building wall are developed to minimize the construction period. This study referred to knowledge and experiences from APR+(Advanced Power Reactor Plus) technical development. The proposed method can be applied to the APR+ in the near future.
This study is to evaluate fatigue resisting capacity of insulated sandwich wall panel under wind-induced fatigue loading. The fatigue loading is calculated based on the probability distribution function (Weilbull and Rayleigh). The serviceability of the insulated sandwich panel was evaluated subjected to the probability-based fatigue loading.
This paper describes the structural behavior of insulated concrete wall panels with EPS insulation. That panels reinforced with Fiber Reinforced Polymer (FRP) truss shear connector to achieve composite action of inner and outer concrete wythes. Main test variables are FRP cross section, width and picth. According to the test result, the shear capacity of increased due to reinforced with FRP truss shear connector. And width 12, 18 mm shear connector need more than 30 mm experiments about reclamation deep.
건축물의 단열은 효율적인 에너지 사용을 위한 필수적인 기술이다. 중단열 콘크리트 외벽 시스템은 내/외측에 두 개의 콘크리트 벽체와 중앙부 단열재로 구성되어, 단열성능과 구조성능을 동시에 만족시킬 수 있는 시스템이다. 중단열 콘크리트 외벽 시스템을 구조체에 적용하기 위해서는 콘크리트와 단열재 부착면의 전단내력에 대한 검증이 필연적으로 요구된다. 본 연구는 파형 FRP 전단연결재로 보강한 중단열 콘크리트 외벽 시스템의 전단연결재의 매립깊이, Pitch, 폭에 따른 전단내력을 평가하기 위하여 실시되었다. 실험결과 동일단면적에서 Pitch가 넓은 경우 전단내력이 소폭으로 증가하는 결과를 보였다. 매립깊이가 깊을수록 전단내력을 증가하였고, 폭 12mm 와 18mm의 경우 각 각 35, 40mm 이상의 매립깊이가 필요할 것으로 판단된다.