The hydrogen valve used in this study is intended to be applied to a automobile, and since there is a limit to the length of the stem, it is necessary to review the optimized stem, and for this, it is required to investigate the heat transfer characteristics of the hydrogen shut-off valve. For this, the temperature of the entire shut-off valve and especially the plunger and O-ring, which are key components in the solenoid valve driving the hydrogen shut-off valve, was calculated using the ANSYS-CFX flow analysis program. From the analysis results, the length of the stem capable of maintaining the design temperature of -40℃ or higher should be at least 139 mm, and it is judged that it should be 140 mm or more considering safety. When determining the stem length of the hydrogen blocking valve for automobiles, constraints on installation in automobiles should be considered.
A computational analysis was performed to study the thermal characteristics within the injection molding process of polygon mirrors in LiDAR systems. Such polygon mirrors are significantly influenced by the geometric shape of the injection mold as well as temperature and operating conditions. The analysis included the temperature distribution, heat flux, and variations in heat transfer rate of the polygon mirror from initial conditions. From the beginning of the injection process, temperature of the polygon mirror changes rapidly, leading to conductive heat transfer to the mold. There are large variations in the mirror temperature change depending on local position, and surface heat flux are affected by internal cooling path. These results are expected to be used as thermal design data for various polygon mirror processes.
The heat transfer characteristics of double-pipe spiral heat exchanger were investigated by various curvature sizes, experimentally. The three different sizes of heat exchanger were made and tested with water as a working fluid to analyze the heat transfer characteristics. The heat transfer rates, overall heat transfer coefficient and pressure drop were analyzed with various heat exchanger sizes (i.e., curvature ratios). As result, the heat transfer rate increased with increasing the size of the heat exchanger as the flow rate increased due to increasing the area size of heat transfer. However, the overall heat transfer coefficient and pressure drop increased with decreasing the heat exchanger size (i.e., increased curvature ratio) due to the enhanced centrifugal force and inertia.
Asphalt concrete(Ascon) is used to repair potholes and cracks. Special truck-mounted cargo boxes transport 200℃ asphalt concrete to repair potholes and cracks. However, long working and transportation hours to repair wide roads decrease the temperature of the asphalt concrete inside the cargo boxes. If the asphalt concrete temperature drops below 170℃, the adhesion with roads that need repair decreases. Therefore, the temperature of the asphalt concrete needs to be maintained for a long time. Conventional asphalt concrete cargo boxes are mostly burner-type models using hot air to prevent the temperature of the asphalt concrete from dropping. However, there are significant temperature differences between the asphalt concrete near and far away from the hot air, so the temperature decreases over time and leads to the disposal of large amounts of asphalt concrete. This causes waste of resources and environmental pollution. Therefore, this study proposed a heat dissipation cut-off type cargo box model to solve this problem and demonstrated its performance over conventional burner-type models through tests and analysis.
PURPOSES : In this study, we aimed to investigate the heat transfer characteristics of asphalt mixtures by water saturation.
METHODS : On the basis of the literature review, the heat transfer characteristics of the samples were analyzed using a thermal accumulation experiment. The types of samples used were WC2 (dense asphalt mixture), ReWC2 (used 30% recycled aggregate), and PA13 (drainage asphalt mixture). The samples were compacted using a gyratory compactor. An infrared lamp simulating insolation was used to continuously heat the asphalt sample. Through this experiment, the upper and lower temperatures and heat flux of the specimen according to its thickness and condition were measured, and the change in its thermal conductivity was analyzed.
RESULTS : The results of the laboratory experiment indicated that the dry sample showed lower thermal conductivity than the saturated sample. The amount of evaporation varied depending on the internal pores of the sample. Additionally, the amount of evaporation changed the heat transfer characteristics of the specimen.
CONCLUSIONS : An asphalt mixture with high porosity decreased the degree of increase in thermal conductivity, compared to mixtures with low porosity, under semi-saturated conditions; this was attributed to the difference in thermal conductivity between air and water during saturation. The results of this study on the heat transfer characteristics of asphalt pavements could be used as basic data for thermal energy harvesting of asphalt pavements.
Solar energy is being constantly studied since it can reduce green house gas by adapting cooling and heating system of domestic architecture as a clean energy source. This study confirmed the reliability of experimental apparatus with temperature measurement of each components by developing cooling and heating system which is combined with artificial solar thermal energy using halogen lamp and refrigerator, examined the heat transfer characteristics according to room internal temperature and lamp distance with the materials of emissive plate (acrylic, copper and stainless). As a result of it, We found that the room internal temperature 18℃ was finer than 21℃ and 24℃ in case of heat transfer rate according to each components. Also, copper in the material change of emissive plate was showed finer heat transfer effects than stainless because of high thermal absorptivity when lamp distance was short.
The effect of flow direction on heat transfer in water cooling channel of lithium-ion battery is numerically investigated. Battery Design StudioⓇ software is used for modeling electro-chemical heat generation in the battery and the conjugated heat transfer is analyzed with the commercial package STAR-CCM+. The result shows that the maximum temperature and temperature difference of battery with Type 1 are the lowest because the heat transfer in the entrance region near the electrode is enhanced. As the inlet velocity is increased, the maximum temperature and temperature difference of battery decreases but the pressure loss increases. The pressure loss in Type 2 channel is the lowest due to the shortest channel length, while the pressure loss with Type 3 or 4 channel is the highest because of the longest channel length. Considering heat transfer performance and pressure loss, Type 1 is the best cooling channel.
In this paper, the heat transfer performance of nanofluids is predicted by numerical analysis methods. The nanoparticles used in this study is SiO2, with concentrations of 1, 2, 3vol.%, and the base fluid is water. Reynolds number of nanofluids ranges from 10,000 to 50,000. A numerical study on the heat transfer characteristics of nanofluid was conducted using a single-phase model. The temperature of the fluid entering from the inlet of the tube is 293.15K. A constant heat flux of 31,650W/m2 was applied at the wall, and the thickness of the wall was ignored. Heat transfer coefficients, thermal conductivity and Nusselt number were selected as indicators for comparing heat transfer performance of nanofluids. As the nanofluid concentration increases, the temperature and velocity distribution by the cross section of the coil tube and straight tube increased. As the Reynolds number increases, temperature difference between inner direction and outer direction reduced in coil tube. For straight tube, the temperature difference between the wall and the center of the tube also decreased.
Nanoporous silica aerogel insulation material is both lightweight and efficient; it has important value in the fields of aerospace, petrochemicals, electric metallurgy, shipbuilding, precision instruments, and so on. A theoretical calculation model and experimental measurement of equivalent thermal conductivity for nanoporous silica aerogel insulation material are introduced in this paper. The heat transfer characteristics and thermal insulation principle of aerogel nano are analyzed. The methods of SiO2 aerogel production are compared. The pressure range of SiO2 aerogel is 1Pa-atmospheric pressure; the temperature range is room temperature-900K. The pore diameter range of particle SiO2 aerogel is about 5 to 100 nm, and the average pore diameter range of about 20 ~ 40 nm. These results show that experimental measurements are in good agreement with theoretical calculation values. For nanoporous silica aerogel insulation material, the heat transfer calculation method suitable for nanotechnology can precisely calculate the equivalent thermal conductivity of aerogel nano insulation materials. The network structure is the reason why the thermal conductivity of the aerogel is very low. Heat transfer of materials is mainly realized by convection, radiation, and heat transfer. Therefore, the thermal conductivity of the heat transfer path in aerogel can be reduced by nanotechnology.
The purpose of this study is to analyze the temperature and heat resistance distribution, which is a criterion for evaluating the cooling performance, by using computer simulation of the cooling system combined with the CPU of the individual highest heat generation section, and use it as important data for the heat sink design. Using a single material of Al 6063-T5, which is an integral part of the desktop, fan and heat sink, fins and base, the analysis was carried out with various fin numbers, thicknesses, pitches and shapes of heat sinks. Ambient temperature, 25°C, heat source, 130W and cooling fan speed, 2500 rpm (50CFM) were used as boundary conditions, and heat transfer characteristics regarding temperature distribution and heat resistance were investigated using ANSYS Icepak. As a result, it has been found that as the number of fins of heat sink increases, the heat dissipation area increases to decrease heat resistance, and as the distance between each fin decreases, the ventilation resistance increases to decrease the flow intensity of the cooling air in contact with the heat dissipation area. The sunburst array also exhibits better heat transfer characteristics by obtaining a lower distribution of heat resistance with a cooling effect of about 10°C than the one-way basic array.
환경풍동 내 공기의 온도와 속도 변화에 대한 공기 유동과 전열 특성을 분석하기 위하여 수치해석을 수행하였다. 풍동 시험부 내 각 단면의 평균 속도, 균일도, 그리고 대류 열전달계수는 노즐 출구의 온도와 속도에 따라 큰 영향을 받게 된다. 노즐 출구로부 터 멀어질수록 평균 속도와 균일도가 점차 감소하고, 노즐 출구의 속도가 50km/h일 때 공기온도가 -40~60oC까지 변화함에 따라 단면 평균 속도와 균일도가 각각 약 12.9%와 13.5% 정도까지 증가하였다. 또한 시험부 바닥의 대류 열전달계수는 50~150km/h의 속도 변화에 대해 약 59.7%까지 증가하였으며, 공기의 온도와 속도가 증가함에 따라 시험부 열 유속도 함께 증가하였다. 본 연구에서 수행한 결과들은 최적의 환경풍동 설계에 필요한 주요 설계 자료로 활용될 수 있을 것으로 기대된다.
Heat transfer and pressure drop of horizontal heat exchangers with different configurations and installations numerically characterized. Three different heat exchangers were used and shaped as linear, wavy, and horizontal slinky, respectively. Installation depth was set from 0.5m to 3.0m and pipe spacing was ranged from 0.3m to 2.1m. The results showed that heat transfer rate and pressure drop were increased with the increase in the installation depth and the pipe spacing. The horizontal slinky heat exchanger carried more heat compared to others due to the greater effective heat transfer surface area per installation area. In terms of a ratio of heat transfer rate to pressure drop indicating the system efficiency, the linear heat exchanger performed better than others. On the other hand, the horizontal slinky heat exchanger was the most effective with respect to a ratio of heat transfer rate to installation cost.
In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/ absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about 40℃ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.
In this paper, we study the effect of cooling dehumidification process and wave heat exchanger on the reduction of white smoke and the efficiency by combination of heat exchanger with numerical analysis method. For this purpose, four types of heat exchange systems combined with 5-stage wave heat exchangers were selected to analyze the heat transfer characteristics of the heat exchange system in the winter condition. As the high temperature exhaust air flowed from HX 1 to HX 5, the final outlet temperatures of the four heat exchange systems(Cases 1, 2, 3 and 4) gradually decreased. The heat transfer rate and dehumidification amount were the best in Case 1 and Case 3, respectively. It can be seen that the heat flow in the heat exchanger is different according to the combination of the four kinds of wave heat exchanger and the fluid flow.
A numerical approach for ventilated disc brake with holes is carried out to investigate the effect of holes on the heat transfer characteristics. The numerical simulation code STAR-CCM+ is utilized to calculate flow and temperature fields with polyhedral meshes. The steady state results show that the holes make the flow velocity on the outer surface increasing, which induce the improvement of convective heat transfer on the outer surface. In the ventilated channel with holes, the convective heat transfer can be reduced due to the inflow of hot air through holes. In unsteady state, the disc has reached the highest temperature in 1,8s since the brake was engaged. The surface of disc without holes has maximum temperatures along the ventilated channels, while the surface temperatures of dis with holes are uniform.
An experimental investigation is performed to study the effect of jet to plate spacing and low Reynolds number on the local heat transfer distribution to normally impinging submerged circular air jet on a smooth and flat surface. A single jet from a straight circular nozzle of length to diameter ratio(l/d) of 83 is tested. Reynolds number based on nozzle exit condition is varied between 500 and 8,000 and jet to plate spacing between 0.5 and 8 nozzle diameter. The local het transfer characteristics are obtained using thermal images from infrared thermal imaging technique. It was observed that at lower Reynolds numbers, the effect of jet to plate distances covered during the study on the stagnation point Nusselt numbers is minimal. At all jet to plate distances, the stagnation point Nusselt numbers decrease monotonically with the maximum occurring at a z/d of 0.5 as opposed to the stagnation point Nusselt numbers at high Reynolds numbers which occur around a z/d of 6.