검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 194

        123.
        2003.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Electrical properties of carbon filler/PVdF [poly(vinylidene fluoride)] composite were investigated as a funtion of carbon filler/PVdF ratio in the range of 0.2~0.5. Three kinds of comercialzied conductive carbon blacks such as Hiblack 41Y, KE300J, and KE600J, and carbon nanofibers prepared by the catalytic chemical vapor deposition of C2H4 over Ni-Cu catalysts were used as the carbon fillers. The electrical conductivity of carbon filler/PVdF composites were in the range of 0.65 to 13.5 S/cm depending the fillers' electrical conductivity ranging from 5.6 to 23.1 S/cm. Among the carbon fillers used, the KE600J carbon black showed the highest conductivity both in the composite and filler itself because of its high degree of graphitization due to the high-temperature thermal treatment and its high surface area due to the activation treatment.
        4,000원
        125.
        2003.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ultra-thin films of amphiphillic squarylium dye were prepared on the hydrophillic substrate by Langmuir-Blodgett(LB) technique. In this study, the photoelectric properties of a amphiphillic squarylium dye LB film was investigated. The visible light(λ = 684nm ) of xenon lamp was illuminated on the amphiphillic squarylium dye LB films and light absorptivity and photoconductivity were observed. The photoconductivity was nearly constant regardless of nominal layer number. The photoelectric properties of the amphiphillic squarylium dye LB films with bottom electrode showed better than that top electrode.
        4,000원
        126.
        2003.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Electron transfer through an Langmuir-Blodgett(LB) monolayer film sandwiched between metal electrodes. We used an eicosanoic acid material and the material was very famous as a thin film insulating material. Eicosanoic acid monolayer was deposited by Langmuir-Blodgett(LB) technique and a subphase was a CdCl2 solution as a 2×10-4 mol/L. Also we used a bottom electrode as an Al/Al2O3 and a top electrode as a Al and Ti/Al. Here, the Al2O3 on the bottom electrode was deposited by thermal evaporation method. The Al2O3 layer was acted on a tunneling barrier and insulating layer in tunnel diode. It was found that the proper transfer surface pressure for film deposition was 25 mN/m and the limiting area per molecule was about 24 a2/molecule. When the positive and negative bias applied to the molecular device, the behavior shows that a tunnel switching characteristics. This result were analyzed regarding various mechanisms.
        4,000원
        129.
        2002.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to investigate the effect of irradiation by 60Co-γrays as well as the e thermal treatment on the dielectric deterioration in ethylene propylene rubber, insulating material for electric cables used in atomic power plants, charging discharging current, residual built- up voltage and dielectric properties are measu discussed in this study. Variance in the characteristic of relative dielectric constant as a function of tem was observed in relatively high dose of irradiation. Since glass transition tem appeared at tens of degree Celsius below zero, the characteristic is attributed orientation polarization. Dielectric loss is generally increased, with increasing d irradiation in the characteristic of dielectric loss as a function of temperature, No d loss by thermal treatment was observed. Dielectric resistance decreases with increa of irradiation in the characteristic of charging current as a function of temperature be considered that dielectric resistance seems to be recovered by thermal treatm characteristic of discharging current as a function of time in the specimen less ir become similar to that of the unirradiated, when thermal treated. A peak is shown residual built- up voltage as a function of time, and the corresponding time of the shorten as increasing dose of irradiation. It is also observed that the corresponding the peak is lengthened by thermal treatment.
        4,000원
        130.
        2002.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        4,000원
        131.
        2002.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The polyimide(PI) Langmuir-Blodgett(LB) ultra thin films were prepared by imidizing the PAAS LB films of PMDA and benzidine system with a thermal treatment at 250℃ for 30min, where the PAAS LB films were formed on substrates by using LB technique. The thicknesses of one layer of PAAS and PI LB film that deposited at the surface pressure of 27mN/m were 20.9 and 4A, respectively. At low electric field, ohmic conduction(I∝ V) was observed and the calculated electrical conductivity was about 4.23×10-15~9.81×10-15S/cm. The dielectric constant of LB film was about 7.0.
        4,000원
        136.
        2002.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the treatment effect of three interventions on the disuse atrophy of rat hindlimb after two weeks suspension. Forty-eight 11~12 weeks old female Sprague-Dawley white rats were divided into four intervention groups: 1) suspension only (S; n=10), 2) intensive weight bearing treadmill (IWBT; n=10), 3) electrical stimulation (ES; n=9), 4) 2)+3) (ES/IWBT; n=9). Another 10 rats received no intervention or hindlimb suspension and served as controls (C). After the interventions, 1) the cross-sectional area (CSA), 2) the ratio of white muscle fiber composition (WMFC), 3) isometric tetanic tension (ITT), and 4) muscle weights (MWs) were measured from the four calf muscle specimens. The results were as follows: 1. In all intervention groups, the CSAs of medial and lateral gastrocnemius (MG LG), soleus (SOL), and flexor digitorum superficialis (FDS) decreased when compared to the control (C) group (p<.05). The CSA increased in FDS and LG for the IWBT group, in SOL for the ES/IWBT group compared to the S only group (p<.05). 2. The ratios of WMFC in MG, LG, SOL, and FDS increased compared to the C group for all interventions (p<.05). The ratios of WMFC decreased in SOL and LG for the IWBT group, in SOL for the ES/IWBT group compared to the S only group, and decreased in SOL for the ES/IWBT group compared to the IWBT group (p<.05). 3. The ITT in the MG, LG, SOL, and FDS decreased compared to the C group for all interventions (p<.05). The ITT increased in MG LG/FDS, SOL, and the whole calf muscles (WCMs) in the IWBT, ES and ES/IWBT groups compared to the S only group (p<.05). 4. The MWs in MG LG/FDS, SOL, WCMs decreased compared to the C group for all interventions (p<.05). The MWs increased in MG LG/FDS and WCMs for the IWBT group, in SOL for the ES group, and in SOL for the ES/IWBT group compared to the S only group (p<.05). 5. In atrophied muscles, the IWBT group showed the best recovery and the ES/IWBT and ES groups followed in decreasing order. The most susceptible muscle to disuse atrophy was the SOL. But conversely, it showed the best recovery in the ES/IWBT group. After two weeks of hindlimb suspension, the calf muscles of rats atrophied and their isometric tension decreased. These changes were best reversed by hindlimb-focused treadmill activity. The next best results were achieved by electrical stimulation combined with the treadmill followed by only electrical stimulation. These findings indicate that full weight bearing treadmill activity alone or in combination with electrical stimulation are effective treatments for non-weight bearing induced muscle atrophy. Further study of the effect of different intensities of electrical stimulation and variations in the duration period of full weight bearing treadmill activity on disuse atrophy is recommended.
        6,400원
        139.
        2001.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기존의 솔레노이드 밸브는 전자부품에 기계적 운동요소를 포함하여 비선형성을 내포하고 있으나, MC 성분의 ER유체를 이용하면, 유동체의 통과부분을 전기장 제어를 통하여 솔레노이드 밸브 기능을 대신할 수 있는 메카니즘을 구현할 수 있을 것으로 사료된다. 유기성인 MC성분 ER유체를 유압시스템에 솔레노이드 밸브 역할에 적용하기 위해, 부과하는 직류 전기장의 사이클 수에 따른 기계적특성에 대한 평가는 다음과 같다. MC성분 ER유체의 전단속도비에 대한 전단응력 분포변화는 2.0kV/mm까지 전기장을 인가했을 경우, 횡축의 전단속도가 증가하여도 종축의 전단응력은 거의 변하지 않았다. 60만 사이클을 반복한 후 ITMC25의 전단응력 실험결과, 2.0kV/mm 이상 전기량을 인가하면 2차원적인 곡선의 형태를 형성하지만 표준편차의 평가치가 오차한계 이내이므로 직선으로 판단하여도 무리가 없을 것으로 사료되었다. 구리 전극으로 전기장을 부과한 경우 MC 성분의 ER유체는 0.1~0.3μm까지의 표면거칠기를 나타냈고, 알루미늄 전극을 사용한 경우는 전기장 부과 초기에 0.3μm의 표면거칠기가 0.2μm로 감소하였으나 40만 사이클의 전기장 부과 이후는 약간의 요철변화가 있었다.(이 논문의 결론 부분임)
        4,000원
        6 7 8 9 10