        1.
        2024.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In modern society, buildings are becoming more complex, and the population is becoming more densely populated. Such large buildings require a variety of evacuation measures, as there is a high possibility of large-scale human casualties due to increased evacuation distance and evacuation time in the event of a fire. Strobe light and exit sign light are used as important evacuation equipment to provide early warning and evacuation directions. In this thesis, we conducted a fire simulation assuming that a fire occurrence point notification function and a strobe light function were added to equipment such as visual alarms and evacuation guidance, and compared and analyzed the difference in evacuation completion time with existing equipment. The scenarios for the simulation were divided into “general fire situations” and “fire location and evacuation exit guidance situation” and the differences in evacuation completion time in the event of a fire were compared and analyzed for each floor from the 1st floor to the 3rd floor. The maximum travel distance to complete evacuation in the case of a fire on the first floor decreased by 80.6 m and the evacuation completion time decreased by 329.4 seconds, and the maximum travel distance to complete evacuation in the case of a second-floor fire decreased by 28.5 m and the evacuation completion time by 438.8 seconds. During the fire on the third floor, the maximum distance decreased until evacuation was completed to 3.4 m, and the evacuation completion time was reduced by 355.6 seconds. It is expected that if the congestion level of evacuation routes is reduced by utilizing the congestion level of evacuation exits when fire alarm systems and evacuation equipment are activated, the evacuation completion time will be further shortened and evacuations will be carried out quickly and safely.
        4,300원
        2.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper attempted to analyze the correlation between the risk image of the evacuees in the tunnel and the variables that affect the evacuation behavior due to the closed feeling. As to whether there is a difference in the level of recognizing the tunnel risk image according to the distribution of jobs, the null hypothesis was rejected at the significance probability of 0.002, so it can be said that the level of recognition of the tunnel risk image varies depending on the job group. In the distribution difference between gender and tunnel risk image recognition level, the significance probability was 0.012, indicating that the null hypothesis was rejected, indicating that the tunnel risk recognition distribution according to gender was different. As a result of analyzing the distribution difference between the tunnel's closed feeling and the tunnel risk perception level, the significance probability was 0.001, and the null hypothesis was rejected, indicating that there was a difference in the tunnel risk image level.
        4,000원
        3.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In general, fire accidents in tunnels are sufficiently preventable, but the damage is very large. Therefore, the number of highway traffic accidents is high in spring when spring fatigue occurs and the traffic volume for maple travel increases. In particular, when analyzing the cause of death of people killed in fire accidents in tunnels, it is analyzed that most of them are suffocated by smoke. Therefore, in this study, it can be said that it is meaningful to make a social contribution to reduce the number of traffic accident deaths by establishing an efficient fire suppression system for fire accidents in tunnels.
        4,000원
        4.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the number of cases of fire spreading due to exterior materials of buildings is increasing. Due to the nature of modern architecture, which emphasizes the aesthetics of buildings, because buildings pursue a splendid appearance, they are inexpensive and have relatively good insulation performance, but an increasing number of buildings are adopting insulation materials that have poor fire safety performance. The risk of spread is also greatly increased. Since the exterior wall of a building is made of a variety of materials and structures, it is composed of a combination of several elements, including materials such as insulation and finishing materials. Therefore, it was determined that it was necessary to introduce a more systematic evaluation method for building exterior materials, and to improve the system reflecting this, away from the existing evaluation method that only checked the fire safety performance of finishing materials.
        4,000원
        5.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        육상 및 해상에서의 화재 사고는 심각한 인명피해를 발생시키며 특히 해양 플랜트 및 선박의 특성 상 밀폐공간으로 인한 질식 사고 사망률이 육상보다 현저히 높다. 이러한 질식사고를 예방하기 위하여 화재에서 발생하는 유독가스를 외부로 배출할 수 있는 환기용 팬의 설치가 필수적이나, 해양화재의 규모를 고려하였을 때 대형 환기용 팬의 설치는 해양 구조물 특성상 용이하지 않다. 따라서 본 연구 에서는 DC 전기장을 인가하여 화재 유독가스를 제어하는 새로운 개념의 소방기술을 개발하고자 한다. 화재 발생 시 대부분의 화염은 화학 이온화로 인해 양전하와 음전하를 다수 함유하고 있고, 이때 전기장을 인가하게 되면 로렌츠 힘에 의해 “이온풍”이 발생하게 된다. 이러한 이온풍을 활용하여 일반건축물과 선박의 단열재로 많이 사용되는 종이와 스티로폼을 연소하여 발생되는 화재연기를 인위적으로 제어하는 실험적 연구를 수행하였다. 실험 결과, ± 5 kV 이상의 직류전압을 인가하였을 때 화재연기를 인위적으로 제어할 수 있었고, 양전압 보다 음전압을 인가하였을 때 상대적으로 효과적인 제어가 가능하였다.
        4,000원
        6.
        2018.04 구독 인증기관 무료, 개인회원 유료
        In the event of an outbreak of fire in an underground subway station, the speed of movement slows down as many people try to evacuate at once and bottlenecks might begin to occur in some locations, potentially resulting in catastrophic accidents. This study aims to analyze egress routes depending on, among other factors that influence evacuation in the event of an outbreak of fire, the characteristics of occupants and the initial points of fire using the GongEgress simulation program. The simulation result shows that the evacuation time of the vulnerable users is found to take 18% longer than that of ordinary people, and the transfer passageways have lower survival probability compared to that of the platforms. Through the analysis of the results, the structural features of the underground subway station and the points of fire are proved to be the major factors that determine the survival probability of the occupants. Therefore, safety training for passengers through conducting fire drills at the station or fire accident simulations can be established in the evacuation route and plan for reaction at the station or fire accident simulations. Key Words : Underground subway station, Fire accident simulations, Evacuation route, Vulnerable users, Transfer station
        4,600원
        8.
        2011.11 구독 인증기관 무료, 개인회원 유료
        Development of the economy and the growing income of people interested in the leisure and health has been focused. Past the town common wells and groundwater around the water, but health is a priority these days to solve the drinking water directly from tap water, but most people work from home, through the water purifier has been resolved. Depending on seasonal changes and personal taste of coffee, if you can enjoy a snack and water purifier is a restaurant, lounge, public areas and focusing on the rapid spread of the fire, water purifier as compared to the total number of fires increased by 0.03% per year trend on, but the washrooms fire and fire-related research data and case studies with analysis of the exact cause lack of proper preventive measures are insufficient reality. In this study, focusing on electrical energy using a water cooler to understand the structure and principles of fire, the fire revealed the mechanism is vulnerable to the consideration of factors, the exact cause of the fire investigation and the Assistant, manufacturing defects, and to contribute to fire prevention review should.
        6,400원
        9.
        2009.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As a results of comparing with fire occurrences and gross national income(GNI), annual fire increasing rate has been 5.6%, and that of GNI has been 11% for the past 55 years. As GNI shows 5.4% higher than fire occurrences, economy growing rate is faster than that of fires. In addition, study has been done every 10 years from 1950's to 2000's. Fire occurrences increase twice as much annually and GNI increases above 3.3 times as much.
        4,000원
        11.
        2003.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The trends in building construction these days are moving towards having better work space and greater suitability for the use of information technology, Therefore people can work in a more relaxed, delightful and pleasant environment. So accidents like fire could cause the mass destruction of human beings. In this paper, we estimated the escape time from a building and simulated the study results on computer to see how safe it would be in a real situation.
        4,200원
        13.
        2015.02 서비스 종료(열람 제한)
        본 연구는 청주시 화재발생자료(2011년 2013년)를 활용하여 화재발생 요인별 특성을 분석하고자 하였다. 이를 위해 청주시에서 발생한 1,436건(2011년 2013년)의 화재발생자료를 활용하여 화재발생분포 현황도를 작성하고, 공간자기상관분석을 통해 청주시의 화재발생 분포 특성을 분석하였다. 연구결과 전역적 모란지수(Global Moran’s I)는 0.40으로 강한 군집적 패턴을 가진 것을 알 수 있었다. 화재발생의 요인별 모란산점도와 국지적 모란지수(Local Moran's Ⅰ)는 실화(요인 1) 0.361, 방화(요인 2) 0.100, 미상(요인 3) 0.188로 강한 자기상관성을 가진 것으로 나타났으며, 자연발화(요인 4)는 –0.010으로 지역적 연관성이 없는 것으로 나타났다. 연구결과는 청주시 화재발생 예방을 위한 정책 수립에 활용이 가능할 것으로 판단된다.
        14.
        2015.02 서비스 종료(열람 제한)
        본 연구에서는 지역 특성이 화재발생 및 피해에 미치는 영향을 분석하였다. 기후변화로 인한 자연환경의 변화와 사회경제적 성장 및 다변화로 인한 사회환경 변화로 지역의 화재발생과 피해가 증가하는 추세이다. 또한 화재는 발생가능성과 피해 측면에서 위험도가 높은 재난유형 중 하나로써 화재발생을 미연에 방지하는 능력과 화재발생 시 신속한 대응하는 것이 중요하다. 그러나 현재 우리나라에서는 지역의 화재발생 가능성을 예측하는 노력이 부족하고, 현재의 소방력 배치기준은 인구 및 관할면적에 의한 단순 배치기준에 머물고 있어 지역의 소방수요를 적절히 반영하지 못하고 있다는 문제가 있다. 이에 지자체 중심의 화재예방 및 대비대책을 수립하고 시행하기 위해서는 지역사회의 사회경제적 여건과 특징을 반영해야할 필요가 있다. 본 연구는 지자체의 사회경제적 특징이 화재발생과 화재피해에 미치는 영향을 알아보고자 하였다. 2008년부터 2013년까지 전국 시군구의 경제, 인구특성, 행정, 시설물 및 토지이용, 지역안전관련 부문에 해당하는 사회경제적 통계지표를 선정하고, 다중회귀분석을 통해 화재발생건수와 화재사망자수, 화재사상자, 화재피해액에 유의미한 영향을 미치는 지표를 파악하고자 하였다. 연구 결과 부문별 사회경제적 통계지표 중 화재발생건수에 유의미한 영향을 미치는 변수를 확인할 수 있었다. 또한 화재로 인한 사망자수, 사상자, 피해액 등 화재피해와 지역특성변수 간 관계성을 파악할 수 있었다. 본 연구는 화재에 영향을 미칠 수 있는 지역의 특성을 파악함으로써 지자체에게 지역의 화재안전도를 높이기 위한 사회경제적 기반을 다질 수 있는 정책우선순위를 제공할 수 있을 것이라 기대된다.
        15.
        2014.02 서비스 종료(열람 제한)
        최근 도심지와 산간지역에 설치되는 도로터널의 경우 터널개소의 증가와 장대화로 화재 사고가 점차 증가되고 있어 터널의 방재시설 강화가 요구되고 있다. 하지만 터널화재 발생시 대규모 인명피해가 발생될 수 있는 연기질식사 방지를 위한 연구는 부족한 실정이다. 본 연구에서는 화재발생시 연기확산을 차단하여 질식사 최소화 및 대피시간을 확보 할 수 있는 에어커튼 시스템을 개발하였다. 에어커튼 시스템은 방재설계 사례를 기준으로 시뮬레이션(CFD)을 통한 최적화 방안(분사각도, 분사량 등)을 도출하였으며, 실내 Lab Test 및 실제 도로터널서 화재실험을 실시한 결과 차연성능을 발휘하였다. 이론적/실험적 검증을 통한 에어커튼 시스템 도입을 통하여 도로터널의 인명피해를 최소화 할 수 있는 새로운 방재시설로 발전되길 기대한다.
        16.
        2012.02 서비스 종료(열람 제한)
        본 연구에서는 전투시스템의 생존성을 향상하기 위한 기술개발의 일환으로서 전투시스템이 외부 위협탄에 의한 충격을 받았을 경우, 전투시스템의 순간화재 발생에 따른 취약성을 분석하는 기법을 개발하고자 전산모사 해석방법을 이용하여 전투시스템의 순간화재 발생 가능성에 대해서 고찰하였다. 전투시스템의 유형은 임의 모형의 전차를 대상으로 선정하였으며, 전차의 구성요소들 가운데 외부 위협탄에 의해 순간화재가 발생할 수 있는 critical component로서는 고폭탄(추진제 포함)과 연료탱크 가운데 연료탱크만을 대상으로 선정하였다. 연료탱크에 주입된 연료는 휘발유, 경유, 등유 세 가지를 선정하고 관련 물성값을 이용하였다. 외부 위협탄은 1,475 m/s의 탄속을 갖는 운동에너지탄 type A와 1,560 m/s의 탄속을 갖는 운동에너지탄 type B로 가정하여 전산모사 해석을 수행하였다. 해석 프로그램은 Autodyn 프로그램을 사용하였고, Shock model을 적용하여 Lagrange process를 사용해서 1㎜ 간격의 계산격자로 계산을 수행한 결과, 평균 2시간 정도(CPU:Intel Core2 Duo, Quad 2.93GHz, RAM:1.75GB)가 소요되었다. 장갑의 두께별 관통된 탄두로부터 연료로의 열전달에 따른 온도값들을 이용하여 연료의 발화온도와 비교하여 순간화재의 발생 가능성을 고찰한 결과, 모든 탄두의 온도가 각각의 연료들의 발화온도보다 낮기 때문에 순간화재가 발생하지 않는 것으로 생각된다.
        17.
        2012.02 서비스 종료(열람 제한)
        본 연구에서는 외부 위협탄 가운데 성형작약탄에 의한 전투시스템의 순간화재에 대한 취약성 분석기법을 개발할 목적으로 성형작약탄이 장갑을 관통하여 가상의 전투시스템 내부의 연료탱크에 충격을 가했을 때, 순간화재의 발생 가능성에 대한 전산해석을 수행하였다. 연료는 휘발유, 경유, 등유를 대상으로 선정하였으며, 성형작약탄은 type A(관통력 800 mm급)와 type B(관통력 300 mm급)를 대상으로 선정하였다. 전산해석 프로그램은 Autodyn을 이용하였으며, 모델방정식은 Shock model을 비교·분석하였다. 해석 프로그램은 Autodyn 프로그램을 사용하였고, Shock model을 적용하여 Lagrange process와 Euler Solver를 사용해서 1~2㎜ 간격의 계산격자로 계산을 수행한 결과, 평균 4시간 정도(CPU:Intel Core2 Duo, Quad 2.93GHz, RAM:1.75GB)가 소요되었다. 순간화재 발생에 대한 확률계산은 각 연료의 인화점을 기준으로 장갑을 관통한 탄두가 연료와 접촉하는 순간의 온도를 비교하여 판단하였다. 이와 같은 연구 결과는 성형작약탄에 의한 전투시스템의 취약성을 분석하는 화재 취약성 확률 계산의 기법으로 활용이 가능할 것으로 사료된다. 장갑의 두께별 관통된 탄두로부터 연료로의 열전달에 따른 온도값들을 이용하여 연료의 인화점과 비교하여 순간화재의 발생 가능성을 고찰한 결과, type A의 경우에는 모든 연료들에 대해서 인화점보다 온도가 높기 때문에 순간화재가 발생할 것으로 예측되며, type B의 경우에는 휘발유에 대해서만 인화점보다 높기 때문에 순간화재가 발생할 수 있지만 다른 두 가지 연료에 대해서는 인화점 대비 온도가 높지 않기 때문에 순간화재의 발생 가능성이 낮은 것으로 판단된다.
        18.
        2011.02 서비스 종료(열람 제한)
        현대 사회에서 차량을 비롯한 선박, 항공기와 같은 각종 수송수단들은 그 용도와 형태도 다양하고 널리 보급되어 있을 뿐만 아니라 각 분야에서 없어서는 안 될 필수품이 되어 있다. 그러나 수송수단의 수와 활용빈도수가 증가함에 따라 그로 인한 차량화재, 선박화재 그리고 항공기화재 등과 같은 특수화재의 발생에 따른 재산 및 인명피해의 문제점들도 함께 늘어나고 있는 실정이다. 또한, 전투시스템의 경우, 외부 충격탄과 폭발물에 의한 충격으로 순간 화재의 위험성 및 사고 가능성이 매우 높기 때문에 이와 같은 화재 및 폭발에 의한 사고예방을 위하여 체계적이고 종합적인 원인 분석과 시스템의 취약성 분석이 필요하다. 따라서 본 연구에서는 이러한 문제점을 해결하고 과학적이며 체계적인 대응방안을 수립하기 위한 기초 자료를 확보하고 이를 통한 전투시스템의 외부충격에 의한 순간화재의 발생예측프로그램을 개발하기 위한 연구를 수행하였다. 연구방법은 각종 수송수단에서 사용되는 차량 내장재 및 오일을 대상으로 연소특성 및 화재하중을 분석하였으며, 실제 사격에 의한 착화유무를 확인하고자 실제 소총사격 실험 및 실내사격장의 사격실험도 병행하였다. 전투시스템의 순간화재발생에 대한 예측프로그램을 개발하기 위해서 실험을 통해 확보한 데이터들로부터 물성 DB를 구축하였고, FTA 방법을 이용하여 순간화재의 발생확률을 산출하였는데 최종적으로 이러한 결과들을 반영하여 Microsoft Visual Studio 2008을 도구로 Microsoft Windows 7의 운영체제에서 실행되는 순간화재 발생 예측프로그램을 개발하였다.