검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 327

        181.
        2015.07 KCI 등재 서비스 종료(열람 제한)
        Waste electrical and electronic equipment (WEEE) has been received much attention recently due to rapid changes in materials and shorter replacement of consumer products. Most of WEEEs are collected and recycled at the designated recycling centers in Korea, and final residues after recycling, sorting and shredding them to separate valuable and recyclable parts in series are left as forms of shredded plastic mixtures, which would be a problem to be resolved. By further plastics separation the polyurethane foams are mostly remained and becomes waste to be treated by appropriate methods. Gasification to produce syngas and incineration to recover energy for such polyurethane foam waste could be utilized instead landfill presently treated. In this study the experiment was conducted to evaluate such performance characteristics of thermal processes. Pelletized solid refuse fuel (SRF) was fabricated to feed into the test furnace even though it was light with low density. Thermogravimetric analysis, proximate analysis and higher heating value were made. During gasification and incineration, gas composition with gaseous pollutants were measured. Due to nitrogen content in polyurethane, nitrogen containing gaseous substances such as NH3 and HCN were observed with varying equivalent air ratios (ERs). The assessment of polyurethane waste foam to energy using incineration and gasification was made with finding out the optimal condition of air injection to emit less pollutants in both operations. Produced syngas could be utilized as energy fuels by lowering pollutants emission.
        182.
        2015.05 서비스 종료(열람 제한)
        활성탄소섬유의 주재료인 탄소섬유는 제조공정이 매우 까다로워 미국, 일본, 유럽의 8개회사 외에는 아직까지 대량생산에 성공한 기업이 없는 실정이고, 활성탄소섬유 시장의 경우 일본의 Toray, Toho Tenax, Mitsubishi Rayon 3개사가 세계시장의 70% 이상을 장악하고 있으며 공기청정용 필터, 정수용 필터 및 용제 회수장치 들이 실용화 되어 있다. 이에 활성탄소섬유의 제조기술을 확보하여 전량수입 사용하고 있는 활성탄소섬유 소재 수입대체 및 국내 환경필터 시장 확대를 모색하고자 한다. 대기질 개선을 위해 도심지역 도외지역 도로변 실태조사를 통해 발생 가능한 유해가스상 물질을 파악하고, 도로변 대기정화에 적합한 Nano Size 기공 분포가 높은 특정 섬유장 분포를 갖는 활성탄소섬유의 개선 및 부직포화, 대기정화 성능개선 및 Filer 압력손실을 최소화한 활성탄소섬유 필터 시작품 제작하여, 유해가스 NOx, VOCs (B, T, X) 성능평가를 통하여 도로변 주변의 차량오염원 등에 의한 주요 가스상 물질의 저감대책 수립에 활용코자 한다.
        183.
        2015.02 서비스 종료(열람 제한)
        현재 국내에는 약 4만여 종의 화학물질이 유통되고 있으며, 매년 약 400여 종의 화학물질이 새로 진입되면서 화학물질의 사용이 꾸준히 증가하고 있다. 이에 따라 구미 불산 누출사고(2012.09), 화성 불산 누출사고(2013.01), A사 지하배관 파손 유독물질 유출사고(2014.02) 등 화학물질 관련 사건이 빈번하게 발생하고 있다. 하지만 현행 토양법 상에는 사고신고 외에 토양사고관련 사항은 부족한 상태이며, 화학물질의 안전관리제도 또한 미비한 상태이다. 토양지하수매체에서 토양법상의 토양사고 대비 능력을 향상시키기 위해서는 실질적인 사전관리체계 제도화가 시급하다. 본 연구는 유해화학물질 누출 시 토양·지하수오염 예방을 위한 위해도 기반 사전관리체계 개발 연구의 1단계 과정으로 오염물질 선정 및 오염취약성 평가체계 framework를 도출하였다. 오염물질 선정은 ‘토양·지하수오염 국가인벤토리 구축기법 개발 연구’ 과제(환경부, 2012)를 통해 제시한 52개의 토양·지하수관련 물질을 대상으로 하였으며, 국내 유해화학물질 목록, 오염물질 유통량 및 배출량 현황 그리고 외국사례 등을 종합적으로 고려하여 평가체계 대상 오염물질을 최종적으로 선정하였다. 대부분의 화학물질 누출사고는 누출, 화재, 폭발 등으로 인해 대기와 토양으로 유입되고 대기로 비산된 물질은 시간이 지남에 따라 해당 범위 내의 토양으로 다시 침적되어 토양오염을 유발한다. 이렇게 충적된 오염물질은 강우 등에 의해 토양 내로 유입되어 지하수까지 오염시키게 되며, 기준노출점에서 토양과 지하수 매체의 오염농도를 산정한 후 인체 및 생태 노출 특성에 따라 오염물질을 등급화 할 수 있다. 이러한 개념을 바탕으로 대상 물질별 사고 시 토양·지하수오염 취약성평가체계 framework를 도출하였다.
        184.
        2015.02 서비스 종료(열람 제한)
        본 연구는 강우 시 발생하는 비점오염물질 중 인과 총 부유성 고형물 분석을 통해 혼합 토지이용에 따른 비점오염 배출 특성을 비교분석하였다. 경기도 용인시 금학천 유역내의 도시지역, 농업우세지역, 혼합토지이용지역, 택지개발지역을 대표하는 총 4개의 소유역 말단에서 강우유출수를 모니터링 하였다. 연구 결과 불투수층이 많은 도시지역은 강우초기에 초기유출현상이 뚜렷하게 발생되었고 다른 지역에 비해 용존성 인의 비가 약 40%정도 높았다. 농업우세지역과 혼합토지이용지역, 택지개발지역은 대부분 인이 고형물에 부착되어 배출되는 입자성 인의 형태를 보였으며, 도시지역과 달리 첨두유량이 발생하는 강우 중기에 가장 높은 농도의 오염물질(TP 및 TSS)이 배출되었다. 모든 모니터링 지점에서 TSS와 TP 농도간 높은 상관성을 나타내고 있어 TP의 배출 제어를 위해서는 TSS의 적절한 제어가 매우 중요함을 알 수 있었다. 특히 택지개발지의 경우 타 토지이용지역에 비해 다량의 토사침식에 의하여 높은 TP 배출부하가 야기될 수도 있음을 예상할 수 있었다.
        185.
        2014.09 KCI 등재 서비스 종료(열람 제한)
        In this study those currently operating pyrolysis oil plant were selected for the investigation. The yield of the oil andfuel was assessed for its use as fuel and the char component analysis, and the reaction time to collect contaminantscollected and analyzed. As the result, about 40% of the oil was yielded and oil could be used as an alternative fuel. Char’sleaching test analysis result was satisfied with the landfill standard. And emission of Dioxin and pollutants was analyzed.The highest concentration of dioxin was 0.7347ng I-TEQ/Sm3. The result satisfied the requirement however the emissionconcentration was changed depending on the input Fuel. Therefore the appropriate pollution control facility should berequired.
        186.
        2014.02 서비스 종료(열람 제한)
        최근 수계에 심각한 악영향을 미치는 비점오염원에 대한 정부의 관심이 대두되고 있다. 비점오염물질은 배출경로가 불명확하며, 배출량 또한 측정하기가 어려워 처리하기 또한 곤란하다. 이러한 비점오염물질 제거를 위하여 비점오염저감시설을 개발 및 설치하고 있다. 하지만 비점오염저감시설 설치 시 대상유역에 대한 연구가 미비하여 명확한 저감효율을 판단하기가 어렵다. 본 연구의 목적은 비점오염물질에 따른 저감시설의 효율을 파악함에 있다. 2년간 총 8회의 강우 모니터링을 통하여 경기도 용인시 경안천 유역에 설치 된 비점오염저감시설 중 식생형 시설인 식생여과대의 저감 효율을 ER(Efficiency Ratio) 방법을 이용하여 산정하였다. 모든 시료는 BOD, COD, TN, TP 항목에대해 수질오염공정시험법에 의거하여 분석하였다. 2012년에서의 저감효율은 각각 36%, 37%, 55%, 44%, 2013년에는 63%, 56%, 48%, 67%로 나타났다. 2년간 각 항목별 저감효율 평균값은 50%, 46%, 52% 56%로 영양염류의 제거효율이 유기물의 제거효율보다 높은 수치를 보였다. 결과적으로 경안천유역 비점오염저감시설 중 식생여과대는 영양염류의 제거에 효율적이며, 저감기능 향상을 위해 지속적인 관리와 연구가 필요하다.
        187.
        2014.02 서비스 종료(열람 제한)
        비점오염원은 점오염원과 다르게 불특정하게 배출되며 유출특성에 대하여 명확한 제시를 하기에 어려움이 있다. 이에 정부는 최근 비점오염원에 대한 문제의 심각성을 인식하고, 비점오염원 관리제도와 관리대책을 마련하는 노력을 기울이고 있다. 본 연구에서는 자연형 비점오염 저감시설인 식생수로의 저감효율을 제거 효율법(Efficiency Ratio, ER)과 부하량 합산법(Summantion of Loads, SOL)으로 산정하였다. ER 방법에 의한 T-N, T-P의 저감효율값은 2012년도에 T-N 80 %, T-P 83 %가 2013년도에 T-N 75 %, T-P 85 %, SOL 방법은 2012년도에 T-N 79 %, T-P 87 %, 2013년도에 T-N 71 %, T-P 73 %로 나타났다. 본 연구에서는 하계와 추계에 대한 저감효율 비교분석을 통해 식생수로의 효율평가를 하였으며, 시설의 계절별 관리방안과 설계에 도움이 될 것이라 판단된다.
        188.
        2013.11 서비스 종료(열람 제한)
        오늘날 다양한 산업분야와 군지기, 공장지역, 매립지 등에서 중금속과 휘발성 오염물질이 동시에 존재하여 심각한 환경오염을 유발하며 인간과 자연에 해를 끼쳐 세계적으로 규제가 강화되고 있다. 특히 p-Xylene은 토양매질에 흡착되지 않으며 노출 시 두통, 호흡장애 등을 유발하며 자정작용이 힘들고 이동속도가 느려 반영구적으로 존재한다. 납은 일상주변에서 접촉이 가능하며 체내에 쉽게 축적되어 신경계통을 마비시키며 뇌에 이상을 일으킨다. 현재 단일물질에 대한 제거는 많이 연구되고 있는 반면 복합오염물질에 대한 연구는 미비한 실정이며 오염물질에 대한 효과적인 제거를 위한 흡착제 개발이 필요하다. 이에 따라 본 연구에서는 망간산화물을 기반으로 하여 계면활성제와의 개질을 통해 TMA-birnessite를 합성하였으며 중금속과 휘발성 오염물질 제거를 판단하기 위해 대표적인 납과 p-Xylene을 이용하여 등온흡착실험과 동역학적실험을 하였다.
        189.
        2013.11 서비스 종료(열람 제한)
        기존의 화석 연료를 대체할 에너지 확보의 중요성이 커짐에 따라, 폐기물도 하나의 자원으로 떠오르고 있다. 특히, 폐기물을 이용하여 가스화를 할 경우 화학연료 또는 발전에 이용할 수 있는 CO, H₂가 주성분인 합성가스를 생산할 수 있다. 그러나 폐기물 가스화의 경우 합성가스뿐만 아니라 미반응된 Carbon 분진과 폐기물에 함유된 성분으로 인해 가스상 오염물질 (HCl, HCN, NH₃ 등)이 발생하게 된다. 합성가스를 이용하기 위해서는 오염물질을 줄이고 합성가스의 순도를 높여야 한다. 그러므로 적절한 운전조건 도출과 최적의 정제 설비 구축이 요구되고, 이를 위해서는 폐기물 가스화를 통해 생성된 오염물질의 배출 특성을 파악할 필요가 있다. 본 연구에서는 폐기물 순산소 가스화를 통하여 생성되는 가스상 오염물질인 HCl, HCN, NH₃와 입자상 물질인 Carbon 분진의 배출량을 확인하였다. 분진의 시료 채취는 정제설비를 기준으로 정제설비 전단과 후단에서 3회 실시하여 분진의 배출량과 제거 효율을 살펴보았다. 가스상 오염물질의 시료채취는 분진과 같은 위치에서 2회 실시하여 비교하였다. 분진의 경우 정제설비 전단에서 평균 5,820 mg/Nm³을 나타내었으나, 정제설비 후단에서는 검출되지 않아, 정제설비를 통해 모두 제거되었음을 확인할 수 있었다. HCl, HCN, NH₃의 경우 정제설비 전단에서 각각 평균 24.87 ppm, 0.02 ppm, 2.19 ppm을 나타내었으며, 정제설비 후단에서 각각 평균 14.38 ppm, 0.01 ppm, 0.25 ppm을 나타내었다. 이들의 평균 제거효율은 42.20%, 52.96%, 88.81%임을 확인하였다. 연구 결과를 통해 입자상 물질인 분진의 경우, 정제설비를 통하여 발생량 대부분이 제거되었다. 그러나 가스상 오염물질 중 HCl의 경우, 제거효율 증가를 위해서 정제 설비에서 사용하는 가성소다의 액/기비 조절 등의 추가적인 연구가 필요하다고 판단된다.
        190.
        2013.11 서비스 종료(열람 제한)
        본 연구는 3개소의 소형 고형연료 사용시설의 대기 배출특성을 분석하였다. 고형연료 사용시설은 RPF 사용 시설과 RDF 사용시설로 구분하였으며, 고형연료 품질특성, 입자상물질 배출특성, 가스상물질 배출특성, 다이옥신 배출특성 및 대기오염물질 배출 상관성분석, 배출원단위 특성을 바탕으로 다음과 같은 결론을 얻었다. 1. 고형연료제품의 RPF제품의 30개 시료의 발열량은 6,004kcal/kg ~ 10,153kcal/kg의 큰 편차를 보이며, 평균 7,846kcal/kg으로 조사되었다. RDF제품의 경우 11개 시료에서 3,065kcal/kg ~ 5,694kcal/kg으로 평균 4,526kcal/kg으로 조사되어, 연소조건의 안정을 위해서는 제품생산의 균질화가 필요한 것을 확인할 수 있으며, 대상시설 반입연료의 품질기준은 만족하나 3개시설 반입고형연료제품 발열량 변화폭이 큰 것으로 확인 되어 고형연료(SRF)를 통합할 경우 연소조건 및 대기오염물질 배출 변동 폭은 더 클 것으로 예상된다. 2. 주요 대기오염물질 배출특성을 살펴본 결과, 입자상물질의 경우 발생되는 양이 방지시설 전단 RPF의 A시설 423.61mg/Sm³, B시설 1223.18mg/Sm³, RDF의 C시설 973.4mg/Sm³ 이며, 보일러 출구 온도의 경우 온도가 높을수록 영향을 크게 받는 것을 확인할 수 있었으며, 온도제어가 오염물질 발생량을 줄일수 있는 방안으로 사료되었다. 가스상 물질의 경우 염화수소와 황산화물 농도가 다른 가스상 물질보다 높은 배출경향을 보이며, 특히 RPF사용시설이 RDF사용시설보다 높은 배출농도 특성을 보이는 것으로 확인되었다. 이는 발열량에 기인한 발생가스량과 밀접한 관계를 시사하며, 완전연소가 되도록 온도, 체류시간, 난류, 산소농도(T.T.T.O)가 조절되어야 하나 소형고형연료사용시설의 운전원이 전문적인 관리자가 아니기 때문에 일시에 다량투입 하는 등 불완전연소를 초래하여 일산화탄소 농도가 주기적으로 높게 배출되는 경향을 나타내고 있다. 3. 배출원단위 특성 검토 결과, 먼지를 제외한 황산화물, 질소산화물, 염화수소의 배출원단위가 국내 종규모 산정 적용 배출원단위 보다 높은 값을 보여 유지관리기준 마련에 세밀한 검토가 필요할 것으로 보인다. 주요 대기오염물질 배출 상관성특성 분석 결과, 대기오염물질 사이의 낮은 상관성을 보이는 것으로 나타났다.
        191.
        2013.07 KCI 등재 서비스 종료(열람 제한)
        Emissions of air pollutants and greenhouse gases (GHGs) from aircraft activities at 11 small-scale airports were investigated using the emissions and dispersion modeling system (EDMS) version 5.1.3 during the two year period of 2009~2010. The number of landing and take-off (LTO) at these airports was dominant for the aircraft type B737, accounting for more than 60% of the total LTOs. Out of the 11 small-scale airports, Gwangju (GJ, RKJJ) airport was the largest emitter of air pollutants and GHGs, whereas Yangyang (YY, RKNY) airport was the smallest emitter. The emissions of NOx and VOCs in 2010 at the 11 airports ranged from 1.9 to 83 ton/y and 0.1 to 17 ton/y, respectively. In 2010, the emissions of CO2 ranged from 394 to 21,217 ton/y. The emissions of most air pollutants (except for NOx and PM10) and GHGs were estimated to be the highest in taxi-out mode. The highest emissions of NOx and PM10 were emitted from climb-out and approach modes, respectively. In addition, the total LTOs at the 11 small-scale airports accounted for the range of 9.3~9.9% of those at four major international airports in Korea. The total emissions of air pollutants and GHGs at the 11 airports ranged from 4.8 to 12% of those at the four major airports.
        192.
        2013.07 KCI 등재 서비스 종료(열람 제한)
        Difference in immobilization effect of heavy metal-contaminated soil between two different amendment methods was evaluated; 1) both of steel slag (i.e., consisted in solid phase) and soluble phosphate (i.e., consisted in liquid phase) were simultaneously applied to contaminated soil (i.e., simultaneous amendment methods) and 2) soluble phosphate and steel slag was applied sequentially to the contaminated soil (i.e., sequentially amendment methods). The application rate of stabilizers to soils was determinated based on weight/weight ratio of 5% for steel slag and PO4/Pb molar ratio of 2.0 for phosphates, respectively. To identify difference of immobilization effect to test soil, three different soluble phosphates, such as Na2HPO4·12H2O, Ca(H2PO4)2·H2O and (NH4)2HPO4 were used. The sequential amendment was 6 ~ 27% more effective than the simultaneous amendment in terms of the immobilization efficiency for Pb, Cu, and Cd in the contaminated soil. There was little difference in case of Zn. Among the three phosphates tested, (NH4)2HPO4 was clearly the most effective. Residual form of heavy metals concentration in sequentially methods is higher than those in simultaneously methods. At the same time, more exchangeable and carbonate-bound forms of heavy metals in simultaneously methods were observed than in sequentially case. These result implies that the sequential amendment method was more effective than the simultaneous amendment method in terms of heavy metal immobilization in the contaminated soil.
        193.
        2013.04 KCI 등재 서비스 종료(열람 제한)
        This study was to investigate the runoff characteristics of non-point pollutants source at the urban area in Suwon city. The highest T-N and T-P concentration of rainfall runoff observed in agricultural area. In residential area, the highest BOD5 and SS concentration of rainfall runoff was investigated. During rainfall events, the peak concentrations of SS and BOD5 were observed after 1~2 hours of rainfall in urban area. Whereas, the peak concentrations occurred within 1~2 hours after rainfall and then the highest concentrations of SS and BOD5 sharply decreased, showing strong first flush effect in urban area. The EMC results indicated that the highest value of T-N and T-P in agricultural area was observed. While residential area was shown the lowest EMC value as T-N and T-P. Non-point pollutant loads on the land use types in urban area were investigated in the order of residential>industrial>agricultural>highway. BOD5 and SS loads on urban watershed were investigated in the order of Suwon>Hwangguji>Seoho>Wonchunri. Whereas, T-N and T-P loads on urban watershed were investigated in the order of Hwangguji>Suwon>Wonchunri>Seho.
        194.
        2013.01 KCI 등재 서비스 종료(열람 제한)
        Studies evaluating the health effects of hazardous air pollutants assume that people's exposure to typical pollutant level is the same as specific regional pollutant level. However, depending on social and demographic factors, time-activity pattern of people can vary widely. Since most people live in indoor environments over 88% of the day, evaluating exposure to hazardous air pollutants is hard to characterize. Objective of this study was to estimate the exposure levels of university students of NO2, VOCs(BTEX) and PM10 using the scenarios with time-activity pattern and indoor concentrations. Using data from time-use survey of National Statistical Office in 2009, we investigated time-activity pattern of university students and hourly major action. A total of 1,057 university students on weekday and 640 on weekend spent their times at indoor house 13.04 hr(54.32%), other indoors 7.70 hr(32.06%), and transportation 2.36 hr(9.83%). Indoor environments in which university students spent their times were mainly house and school. Air pollutants concentrations of other indoor environments except house and school such as bar, internet cafe and billiard hall were higher than outdoors, indicating that indoor to outdoor ratios were above 1. According to three types of exposure scenarios, exposure to air pollutants could be reduced by going home after school.
        195.
        2012.12 KCI 등재 서비스 종료(열람 제한)
        In this study, an experiment was conducted on influent water with low concentrations of organic matter, such as river water or secondary treatment water of a sewage treatment plant, according to HRT changes by using aerobic biofilm. In the biofilm process, as the biofilm increases in thickness, the inner membrane can be low in oxygen transfer rate and become anaerobic conditions, while the detachment of biomass from biofilm occurs. To overcome these limitations in the detachment of microorganisms in biofilm, the yarn, which was made from poly propylene(PP), was weaved and manufactured into a tube. Then, a test was carried out by injecting air so that the interior of the biofilm could create aerobic conditions. The results of the experiment showed that the removal efficiency of TCODcr reached 66.1∼81.2% by HRT 2hr, and 50.9 ∼61.8% after HRT 1 hr. The removal efficiency of SCODcr was 45.9 to 55.1% by HRT 1hr, and 26.1% in HRT 0.5hr, showing the highest removal efficiency in HRT 1hr. The SS removal efficiency was at 81.8 to 94.6%, and the effluent SS concentration was very low, indicating less than 2.2 mg/L in all HRT's. As a result, the SCODcr and NH4 +-N that were removed per specific surface area and attached to microbial biofilm showed the highest efficiency in HRT 1hr with 8.37 gSCODcr/m2·d, 2.93 gNH4 +-N/m2·d. From the result of reviewing the characteristics of biofilm growth, microorganisms were found to be attached, and increased by 36 days. Later, they decreased in number through detachment, but showed a tendency to increase again 41 days later due to microbial reproduction.
        196.
        2012.10 KCI 등재 서비스 종료(열람 제한)
        Yongsan ward is located at central place connecting south and north ecology axis of seoul. Various environment-friendly Yongsan development could pose positive effects on NPS(non pollutant source) pollutant reductions and water quality improvement at Han-rive because BOD, T-N, and T-P NPS discharges took 90% of total pollutant from this area. In this study, direct runoff and NPS pollutant loads were evaluated before and after development using spatio-tamporal change in CN(curve number) and EMC(event mean concentration) data. It was found that direct runoff value is 23,584,724 m3, and BOD, T-N and T-P loads are 104,456 kg/year, 111,483 kg/year and 7,500 kg/year under pre-development condition, respectively. Annual runoff, BOD, T-N and T-P reducing rate were 12.9%, 33.3%, 35.6% and 40.7% under integrated post-development condition, respectively. Based on the results obtained in this study, environment-friendly urban development could be achieved at Yongsan area.
        197.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        The impact of a considerable increase in traffic volume on the emission and concentrations of air pollutants was investigated at three beaches (Haeundae (HB), Gwanganri (GB), and Songjeong (SB)) in Busan during beach opening period (BOP) in 2011. During the BOP, passenger car was the major vehicle type, followed by taxi, and van. CO was the major contributor of total air pollutant emissions followed by NOx, VOC, and PM10. For the temporal variation of the emission of air pollutants during the BOP, it was generally the highest in the afternoon followed by the evening and morning, except for SB. For the spatial variation of their emission, it was the highest at GB followed by SB and HB. The emissions of air pollutants during the BOP were generally higher than those during the Non-BOP, except for HB. In contrast, the significant impact of the traffic volume increase on the concentrations of air pollutants at monitoring sites near the three beaches during the BOP were not found compared to the Non-BOP due to the significant distances between monitoring sites of air pollutants and monitoring sites of traffic volume at the beaches.
        198.
        2012.02 KCI 등재 서비스 종료(열람 제한)
        The emissions of several air pollutants (NOx, CO, VOCs, etc.) for the replacement of all diesel buses by Compressed Natural Gas (CNG) buses were estimated in the Busan Metropolitan Area (BMA). These emissions were calculated from emission factors considering the different driving speeds with bus routes, distance traveled, and deterioration factors. For the purpose of this study, three categories of fuel type were selected: (1) the combination of diesel (65%) and CNG buses (35%) (DSL+CNG case), (2) all diesel buses (DSL case), and (3) all CNG buses (CNG case). The emissions of NOx and CO in the CNG case were estimated to be significant decreases (by about 50% and 98%, respectively) relative to the DSL case. Conversely, the emission of VOCs (980.7 ton/year) in the CNG case were a factor of 3.3 higher than that (299.8 ton/year) in the DSL case. In addition, the diurnal variations of emissions between two city buses (e.g. diesel and CNG) and all other vehicles were distinctly different because the two city buses operate at a regular time interval. Our overall results suggest the possibility that the pollutant emissions from the CNG buses can exert less influence on air quality in the target area than those from the diesel buses.
        200.
        2011.10 KCI 등재 서비스 종료(열람 제한)
        In this study, occurrence status of nonpoint pollutants and characteristics of discharge by each nonpoint pollutants were examined through monitoring on nonpoint pollutants caused when raining in vineyard belonging to the agricultural area of various land use patterns. Also, the first flush analysis limited to studies on the existing non-percolation area was applied to percolation area to ascertain availability and criteria of study. Various water quality and sluice of nonpoint pollutants were analyzed, based on which discharge of nonpoint pollutants in agricultural area was ascertained to be influenced greatly by artificial factors such as period, cultivation, management, etc. Meanwhile, the first flush phenomenon at agricultural area was ascertained to occur, and the first flush was quantified through calculation of the first flush ratio. If MFF30 is based, discharge load by each nonpoint pollutants caused when raining was investigated to include 40.8% on the basis of total discharge. In case of SS in pollutants showed the highest first flush phenomenon of 64.8%. Through such a result, calculation possibility of the initial rain criteria was ascertained, and it was determined that reliability-assured criteria were calculated through further monitoring.