The change in the performance of the range hood according to the pressure change was investigated through a comparative experiment, and the conclusion is as follows. KS C 9304: In 2020, static pressure was applied at 100 Pa according to the fan standard, and the test was conducted by varying the outlet diameter and power consumption. In the case of Motor power 55W, the air volume value was 184.6 when the outlet diameter was 125mm. As a result of the test, if the power consumption is 52.0W, the diameter of the outlet is 125mm, and the power consumption is 60.8W, and the diameter of the outlet is 100mm, it meets 160 or more and less than 200 (constant pressure 100Pa).
This study aims to measure sedimentation status change with the changes in internal pressure for dry chemical extinguishers of various use periods and analyze the suitability of the fire extinguishers' performance criteria. When the internal pressure of the fire extinguisher is 0%, 2 out of 10 new dry chemical powders for the 5 elapsed years were noted to be suitable, including 3 recycled dry chemical powders with 5 elapsed years that were found eligible. One out of 10 new dry chemical powders for 10 elapsed years was shown as suitable. Also, one new dry chemical powder for 13 elapsed years was suitable. When the internal pressure of the fire extinguisher was 50%, all 10 out of 10 new dry chemical powders for 5 years, recycled one with 5 elapsed years, and a new one with 10 elapsed years were found to be suitable, while 9 new dry chemical powders for 13 years were shown as suitable. When the internal pressure of the fire extinguisher was normal, new ones with 5 elapsed years, recycled ones with 5 elapsed years, new ones with 10 elapsed years, and new ones with 13 elapsed years were all 10 out of 10 samples noted as suitable. In summarizing the experiment results, it was found that the sedimentation status, one of the fire extinguisher's physical properties experiments, affects the fire extinguisher's performance criteria rather than the change with use periods.
In this study, a graphite block is fabricated using artificial graphite processing byproduct and phenolic resin as raw materials. Mechanical and electrical property changes are confirmed due to the preforming method. After fabricating preforms at 50, 100, and 150 MPa, CIP molding at 150 MPa is followed by heat treatment to prepare a graphite block. 150UP-CIP shows a 12.9% reduction in porosity compared with the 150 MPa preform. As the porosity is decreased, the bulk density, flexural strength, and shore hardness are increased by 14.9%, 102.4%, and 13.7%, respectively; and the deviation of density and electrical resistivity are decreased by 51.9% and 34.1%, respectively. Therefore, as the preforming pressure increases, the porosity decreases, and the electrical and mechanical properties improve.
In this paper, we break away from the method of removing and inspecting the GDI injector, measure the pressure change of the fuel rail pressure sensor when driving the GDI injector of a vehicle equipped with the GDI fuel system, and compare the results. analyzed.There was a pressure change in the fuel rail pressure sensor from the general drive GDI injector. There was no pressure change in the fuel rail pressure sensor when driving the GDI injector without injecting fuel. You can check the fuel injection status in the pressure change data of the fuel rail pressure sensor without removal the GDI injector.
In this study, a ZnS film of 8-mm thickness was prepared on graphite using a hot-wall-type CVD technique. The ZnS thick film was then hot isostatically pressed under different pressures (125–205 MPa) in an argon atmosphere. The effects of pressure were systematically studied in terms of crystallographic orientation, grain size, density, and transmittance during the HIP process. X-ray diffraction pattern analysis revealed that the preferred (111) orientation was well developed after a pressure of 80 MPa was applied during the HIP process. A high transmittance of 61.8% in HIPZnS was obtained under the optimal conditions (1010oC, 205MPa, 6 h) as compared with a range of approximately 10% for the CVD-ZnS thick film under a 550-nm wavelength. In addition, the main cause of the improvement in transmittance was determined to be the disappearance of the scattering factor due to grain growth and the increase in density.
The change in the open porosity of bulk graphite as a function of the uniaxial molding pressure during manufacturing is studied using artificial graphite powder. Subsequently, the graphite is impregnated to determine the effect of the open porosity on the impregnation efficiency and to improve the density of the final bulk graphite. Bulk graphite is manufactured with different uniaxial molding pressures after mixing graphite powder, which is the by-product of processing the final graphite products and phenolic resin. The bulk density and open porosity are measured using the Archimedes method. The bulk density and open porosity of bulk graphite increase as the molding pressure increases. The open porosity of molded bulk graphite is 25.35% at 30 MPa and 29.84% at 300 MPa. It is confirmed that the impregnation efficiency increases when the impregnation process is performed on a specimen with large open porosity. In this study, the bulk density of bulk graphite molded at 300 MPa is 11.06% higher than that before impregnation, which is the highest reported increase. Therefore, it is expected that the higher the uniaxial pressure, the higher the density of bulk graphite.
The change in pressure measurement according to the low pressure tap blockage rate of the Venturi flowmeter used in domestic nuclear power plants was approached numerically. Blockage rates were modeled dividing by 1/10dT to the downstream side of the low pressure tab to identify differential pressure changes. As a result, differential pressure increased in proportion to the blockage rate, and there was no change in differential pressure measurement at 10 to 40 percent with relatively small blockage rate, but the error rate of 50% to 0.3% or higher was shown.
해저 파이프라인은 자원개발을 포함한 에너지산업 및 철강산업과 연계한 고부가가치 산업으로서 상당한 관심을 받아왔다. 해저 파이프라인의 설계와 설치 프로젝트 수행을 위해서는 다양한 핵심요소기술들이 필요하다. 특히, 해저 파이프라인의 안전한 운영을 위해서는 예비커미셔닝을 통한 철저한 사전검증과정이 필수 불가결한 부분이다. 해저 파이프라인 예비커미셔닝 과정 중 하이드로테스팅 공정은 파이프라인 주위 온도변화에 크게 영향을 받는 것으로 알려져 있으나 이에 관한 이론적, 수치해석적 접근방법을 활용한 연구는 미미한 편이다. 본 연구에서는 해저 파이프라인의 예비커미셔닝 과정 중 하이드로테스팅 공정에 대해 과도열전달 해석법을 활용하여 내부 온도변화량 산정 및 이를 활용한 파이프라인 내부 압력변동량 예측법을 제시하였고 예측된 결과를 현장 실계측 데이터와 비교·검토하여 그 유효성을 입증하였다. 제안된 해석절차는 해저 파이프라인 설치 프로젝트 수행 사전단계에서부터 파이프라인 열전달 시뮬레이션을 통해 압력변동량 예측을 가능하게 함으로써 해저 파이프라인 설치 프로젝트의 생산성 향상에 크게 기여할 것으로 사료된다.
정삼투막(Forward osomosis, FO) 공정은 차세대 해수담수화 기술 중 하나이 다. FO 공정은 운영에너지나 막오염의 장점에도 불구하고 유도용액의 분리회수 등의 문제로 실증화 단계에 어려움이 있다. 따라서 현재 FO 공정에 대해서는 FO를 단독으로 사용하기보다 RO 전단에 FO 공정을 두어 이용하는 hybrid 시스 템으로 이용하려는 연구가 많이 진행되고 있다. 본 연구는 유도용액의 분리회수 가 필요하지 않은 FO-RO 공정에서의 성능 지표 중 하나인 투과유량을 늘리기 위해 공정 운전 조건 중 유도용액의 유량변화에 따른 성능을 평가하였다.
본 연구의 목적은 충격흡수 및 통기기능 인솔을 적용한 개발 전투화의 족저압력 및 온도변화를 연구하는데 있다. 남성 피험자 11명(age: 21.8±2.2 yrs, height: 174.3±3.6 cm, weight: 71.6±8.6 kg, foot length: 261.0±1.0 mm)을 대상으로 총 3종류 전투화의 족저압력 및 온도 변화를 비교하였다: 전투화 A(보급형 일반 전투화), 전투화 B(통기구가 적용된 개발 전투화), 전투화 C(전투화 B에 통기기능 및 충 격흡수용 인솔 적용). 족저압력 측정을 위해 Pedar-X를 사용하였고, 전투화의 내부온도는 휴대용 써미스터의 온도센서를 사용하였다. 전투화의 종류별 족저압력 및 온도 변화결과를 비교하기 위해 일원변량분석 (one-way ANOVA)을 실시한 결과, 첫째, 족저압력 변인에서, 기능성 인솔을 적용한 전투화 C가 전투화 A보다 오른발/왼발 후족부의 최대족저압력에서 통계적으로 유의하게 낮았으며, 전투화 C가 전투화 B보다 왼발 후족부의 평균족저압력에서 통계적으로 유의하게 낮은 압력을 나타내었다. 둘째, 내부온도에서 보행 시작 후 40분경과 시점부터 개발 전투화인 B, C가 일반 전투화인 A보다 낮은 내부 온도를 보였다.
The Pressure Retarded Osmosis (PRO) is the next generation desalination technique and is considered as a eco-friendly energy. This was conducted to evaluate the effect of the temperature and pressure on the PRO performance. The flux of the permeation was measured under different operating conditions and estimated the power density. An improvement of PRO performance is depend on increasing solution temperature and optimum pressure. The effect of increasing feed solution temperature has stronger impact on the PRO performance comparing to the draw solution temperature. The reason of the results was due to the change of osmotic power, viscosity, water permeability and structure parameter(s).