검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 31

        1.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Vulnerable populations in healthcare facilities are more sensitive to exposure to indoor air pollutants, and therefore are more affected by such pollutants than the general population. This was the underlying reason why studies of indoor air pollutant concentration distribution and health risk assessment have been conducted targeting facilities, such as daycare centers, medical facilities, elderly care facilities, and postnatal care centers. However, previous studies have mainly focused on daycare and medical facilities for their research, and relatively speaking, studies conducted on the other venues are lacking. Therefore, this study aims to present the current status of indoor air quality and perform a health risk assessment in regard to Formaldehyde exposure at postnatal care centers and elderly care facilities. Here, the study focused on facilities that had undergone pollution level inspections from January 2017 to December 2021. A total of 81 postnatal care centers and 48 elderly care facilities were selected as the subject of the study. Then, the study utilized concentrations of five elements (CO2, HCHO, PM10, PM2.5, TBC) to determine the status of indoor air quality of both postnatal care centers and elderly care facilities. For health risk assessment, HCHO concentration was used. The investigation demonstrated that the yearly average concentration of the five elements stood within the indoor air quality maintenance standards, and the ratio of PM2.5 to PM10 in the two types of facilities was distributed as high as about 70%. In addition, the study showed that HCHO and TBC demonstrated a positive correlation when the relationship between indoor temperature and humidity with the five elements was examined. The health risk assessment showed that the cancer risk level of postnatal care center users stood below 10-6, below the level that is perceived as an acceptable risk. The cancer risk of workers from both postnatal care centers and elderly care facilities and elderly care facility users exceeded the acceptable risk level of 10-6, but was shown to be below 10-4, the maximum acceptable risk.
        4,000원
        2.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, 40 residents of the Gwangyang and Yeosu areas were assessed for their level of exposure to heavy metals (As, Cd, Ni) from April 2017 to June 2018. The aim was to understand the differences in levels of indoor exposure to heavy metals (As, Cd, Ni), and a health risk assessment was conducted to determine whether there was any fatal cause from carcinogenic elements. The mean concentrations of PM10 particles indoors were As 0.24 μg/m3, Cd 0.07 μg/m3, and Ni 0.89 μg/m3. The health risk assessment for the arsenic, cadmium, and nickel in indoor air confirmed that the mean values exceeded the cancer risk tolerances specified by the U.S. EPA, for As (males 3.07 × 10−4, females 3.35 × 10−4), Cd (males 3.83 × 10−5, females 4.18 × 10−5), and Ni (males 6.36 × 10−5, females 6.95 × 10−5).
        4,000원
        3.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted targeting 30 residents of Gwangyang industrial complex area from April to May 2017 to assess their level of exposure to VOCs and conduct a health risk assessment for individual exposure. The aim was to understand the difference in levels of indoor, outdoor and personal exposure to VOCs (benzene, toluene, ethylbenzene, m-xylene, p-xylene, o-xylene) and a health risk assessment was conducted to determine whether there was any fatal cause from carcinogenic or non-carcinogenic elements from a respiratory disease patients. In the case of benzene in the air, the geometric levels of the group are indoor, outdoor and personal exposure; on the CTE, RME condition and Monte-Carlo analysis, all subjects were seen to exceed the carcinogenicity tolerance of 10−6 specified by the US EPA. In the case of toluene, ethylbenzene, m-xylene, p-xylene, o-xylene on the CTE, RME condition and Monte-Carlo analysis, the non-carcinogenic standard of 1 was not exceeded.
        4,000원
        4.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we analyzed the factors affecting the concentration of airborne asbestos fiber in the indoor and outdoor environment of a slate roofing house, and performed a health risk assessment of residents living in houses with slate roofs. Sampling was conducted at ten houses with slate roofs on 3 different days under different weather conditions. A high flow rate pump was used for sampling. The specimen was assessed using a phase-contrast microscope. The degree of risk of exposure to asbestos was assessed using EPA’s carcinogen risk assessment method. Asbestos fiber concentrations for slate roofing houses were 2.43 fiber/L inside and 2.46 fiber/L outside, respectively. The correlation between the indoor and outdoor asbestos fiber concentration was 0.486. But on both sides, the asbestos fiber concentrations did not exceed the standard (10 fiber/L) for ambient air in Korea. The factors affecting the concentration of asbestos fiber were year of construction (p<0.05), total roof area (p<0.05) and average wind velocity (p<0.01). According to EPA’s ELCR (Excess Lifetime Cancer Risk) on air pollution substances, a level of 1.0E-04~1.0E-06 should be maintained. However, the ELCR level of 6 out of 10 houses was over 1.0E-04. Therefore, a risk management plan for residents of slate roofing houses must be prepared immediately.
        4,000원
        5.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study measured and analyzed the heavy metal (Cd, As) content of fine dust in the city of Gwangyang, Jeonnam from September 19 to September 22, 2016. For cadmium, the arithmetic average was 0.21 ng/m3 (0.12~0.49 ng/ m3), which did not exceed the WHO's recommended level. The average of arsenic was 2.41 ng/m3 (0.30~142.08 ng/ m3) and the geometric mean was 11.18 ng/m3, which exceeded the WHO's recommended standard in 16 out of 24 measurements. In the case of cadmium, the CTE of male was 9.22 × 10−8 RME 1.91 × 10−7 and the female CTE was 9.44 × 10−8 RME 1.92 × 10−7, which did not exceed the EPA limit of CTE 2.18 × 10−5 RME 1.51 × 10−4 for men and CTE 2.23 × 10−5 RME 1.51 × 10−4 For women, CTE 2.23 × 10−5 RME 1.51 × 10−4 results were obtained, which exceeded the EPA's recommended limit and also exceeded the maximum allowable limit of 10-4.
        4,000원
        6.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the Ministry of Labour, published clause 2 of Article 41 (Risk Assessment) of the Act "Industrial Safety and Health" dated 12 June 2013 in connection with continuous increase of accidents at construction sites in order to prevent accidents in industrial safety and health in new construction in accordance with the risk assessment on construction projects are realized after March 13, 2014. In this paper, positive method of calculating risk discussed by performing research the awareness of general contractors and sub-contractors with presenting risky situation is considered. The purpose will be a positive method of calculating risk and would be a sufficient basе and give a positive direction in the development of new systems currently working in the construction and risk assessment which consider the characteristics of sufficient risk assessment system for future research.
        4,000원
        7.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Volatile organic compounds(VOCs) detected frequently in the indoor air of child-care centers causes neurological disorders, lung, eyes, and bronchial irritation, and acute and chronic toxicity. In this study, the distributions of carcinogenic VOCs detected in child-care centers were characterized and a health risk assessment of the VOCs was performed, which can provide the necessary information for drawing up safety plans with respect to the concerned materials. The sampling of sites in day-care centers was undertaken two times: in the morning (10:00~12:00), and afternoon(16:00~20:00)-at 23 daycare centers located in Seoul, Korea from April, 2012 to July, 2012. The overall average concentrations of individual VOCs were benzene(1.61 μg/m3) > carbon tetrachloride (0.78 μg/m3) > chloroform(0.67 μg/m3) in order. Indoor/outdoor(I/O) ratios of benzene, carbon tetrachloride, chloroform were 1.33, 1.09, 1.72, respectively. Benzene and carbon tetrachloride are thought to be more strongly associated with outdoor sources as compared to chloroform. Spearman correlation of benzene, carbon tetrachloride between indoor and outdoor concentration showed statistically significant levels(p < 0.05). The linear correlations for benzene, styrene, and carbon tetrachloride were tested. A significant correlation was observed only for carbon tetrachloride, accounting for 83 % of the variance. The risk assessment of the carcinogenic VOCs for teachers, infants, and children showed that none of the targeted VOCs posed a serious risk.
        4,000원
        8.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The occupational health and safety accidents were continuously increased during handling, usage and manufacturing the chemical materials according to increase of small and medium sized enterprises in domestic industries. These accidents mainly resulted from insufficient occupational health and safety management and deteriorative facilities and focused on corresponding operation to minimize the damage of accidents after occurrence. But, it was required that we grasped the occurrence causes of occupational health and safety risk in handling, usage and manufacturing the chemical materials and develop the adequate corresponding operation and system according to the possible occurrence of occupational health and safety risk. This study deals with the development of risk assessment model to derive the risk and important risk of occupational health and safety and then help to construct the self-controlled occupational health and safety system for small and medium sized enterprises handling the chemical materials.
        4,000원
        9.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to evaluate the health risk of workers exposed to phenyl glycidyl ether to prevent themfrom developing occupational diseases. The workplaces that coat floor with epoxy were selected and the sampleswere collected and analyzed with NIOSH 1619 Method. Unit risk was calculated according to the animalcarcinogenicity study. Excess cancer risk was also calculated by multiplying unit risk by exposure concentration.Monte Carlo simulation was performed to calculate the median, cumulative 90%, and cumulative 95% value.Phenyl glycidyl ether is a skin, eye irritator and can result in allergic reaction, nausea, intoxication. Unit risk wascalculated as 0.04 (mg/m³)-¹ based on the tumor incidence in rats. Geometric mean and geometric standarddeviation was also calculated as 0.112 ppm and 0.223, respectively by the workplace environment measurements.The median, cumulative 90%, and cumulative 95% value of excess cancer risk were calculated as 0.0244, 0.1328,0.1596, respectively. Not only cumulative 90% and cumulative 95% value but also the median of excess cancerrisk is much higher than 1×10-⁴ by the risk characterization, so there is a possibility of carcinogenesis to workers.Therefore, supervisors or managers of each workplace have to keep doing the risk management of their workplacesfor workers to reduce exposure to phenyl glycidyl ether.
        4,000원
        10.
        2013.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was performed to investigate the distribution of indoor air pollutants in medical facility in Gyeonggi-do area from February to November, 2012, and to conduct the health risk assessment from obtained data. PM10, CO₂, formaldehyde, CO, and total bacteria count(TBC) did not exceed the maintained standards, but mean concentration of TVOC was 402.3 ㎍/㎥ and thirteen of them exceeded the recommended standard. In the concentration distribution of pollutants for the monthly samples, CO₂, formaldehyde, TVOC, TBC were the highest level in August. From the factor analysis of indoor air pollution provided three factors; the first factor was seasonal factor (indoor temperature and humidity, TBC and formaldehyde), the second factor was ventilation factor (CO₂, PM10 and CO), and the third factor was building(or interior) factor (TVOCs). In the health risk assessment results, the excess carcinogenesis of formaldehyde for resonable maximum exposure worker was 1.21×10-⁴ which means exceeding the cancer criteria(1.0×10-⁴). We confirmed the probability of health effect caused by TVOC. The lifetime excess cancer risk of carcinogens(benzene, formaldehyde) and hazard quotient of non-carcinogens(toluene, ethylbenzene, xylene, styrene), and risk of regulation substances(PM10, CO₂) were safety level for inpatients and out patients.
        4,600원
        12.
        2013.04 구독 인증기관 무료, 개인회원 유료
        According to Department of labor guideline “2012-104 (2012.9.26.)” This study is to suggest the basic information and the improvement for the application of risk assessment on a construction site by group interview & survey of construction worker who is the practice of the subject and then numerical analysis about awareness and action plan of Safety and health. The result of group interview and survey of construction worker, most of construction worker feel the danger during the work. Then construction worker analysis results that risk assessment helps to change & raise awareness of safety and reduce an industrial disaster. Easy Safety management activity such as TBM & safety education active will be necessary for safe worksite and then I suggest the TBT(tool box talk) active which combines TBM & safety education.
        4,300원
        13.
        2012.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The objective of the present study was to estimate the health risk level for children exposed to phthalate and identify the pathways including indoor floor dust, surface wipe and hand wipe in elementary-schools and institutes. The samples of indoor place were collected at children's facilities (50 elementary-schools and 46 academies) in summer (Aug ~ Sept, 2008), winter (Dec 2008 ~ Feb, 2009) and Spring (Mar ~ Apr, 2009) periods. Hazard Index (HI) were estimated for the non-carcinogens and the examined phthalate were diethylhexyl phthalate (DEHP), dibutyl-n-butyl phthalate (DnBP), butylbenzyl phthalate (BBzP). Risk analysis indicates that did not exceed 0.01 (HI) for all subjects in all facilities it's 50th % and 95th % value. For DEHP, DnBP and BBzP their detection rates through multi-pathways were high and their risk based on health risk assessment was also observed to be acceptable.
        4,800원
        14.
        2012.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to calculate the health risks which children were exposed to trace metals through several pathways including air, floor dust, wipe and hand wipes in elementary-schools and academies. The samples were collected at children's facilities (50 elementary-schools and 46 academies) in summer (Aug ~ Sept, 2008), winter (Dec 2008 ~ Feb, 2009) and Spring (Mar ~ Apr, 2009) periods. The lifetime Excess Cancer Risks (ECRs) were estimated for carcinogen trace elements such as As, Cd, and Cr. For carcinogens, the Excess Cancer Risk (ECR) was calculated by considering the process of deciding Cancer Potency Factor (CPF) and Age Dependent Adjust Factor (ADAF) of the data of adults. Hazard Quotients (HQs) were estimated for the non-carcinogens trace metals like Cd, Cr, Hg and Pb. The average ECRs for young children were 1×10-9~1×10-8 (50%th percentile) level in all facilities. Non-carcinogens did not exceed 0.1 for all subjects in all facilities. For trace metals their risk based on health risk assessment was also observed to be acceptable.
        4,900원
        15.
        2012.04 구독 인증기관 무료, 개인회원 유료
        Risk Assessment, a basis of health and safety management system, is an calamity prevention activity which regularly measure the level of a risk to passively improve potential hazard. A problem, the assessment not being improved to be applied to the construction work site where requires diversity and complexity, causes the assessment to be inefficient to bring quality results. A study on the investigates and compares the surveyed degree of recognitions of workers who works in companies executing the risk assessment By the investigation and comparison, it is expected to bring the better solution for early and efficient application for those companies which are not taking the risk assessment.
        4,200원
        16.
        2012.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the health risk and management of childhood exposure to indoor aldehydes in elementary-schools and academies. The samples were collected at children's facilities (50 elementary-schools and 46 academies) in summer (Aug ~ Sept, 2008), winter (Dec 2008 ~ Feb, 2009) and Spring (Mar ~ Apr, 2009) periods. The overall mean concentration of formaldehyde was 68.3 ㎍ /m3 and 27.2% of exceeded the 100 ㎍/m3 by the school health guideline. The concentration ratio of Indoor air and outdoor air (I/O) of aldehydes exceeds 1.0. The level of indoor air contamination did appear to be high, and 24.6% of the academies evaluated had exceeded the formaldehyde level specified by the public health act (120㎍ /m3). We estimated the lifetime excess cancer risks (ECRs) of formaldehyde, and the hazard quotients (HQs) of non-carcinogens (acetaldehyde and benzaldehyde). In addition, for carcinogens, the excess cancer risk (ECR) was calculated by considering the process of deciding cancer potency factor (CPF) and age dependent adjust Factor (ADAF) of the data of adults. The average ECRs of formaldehyde for young children were 1×10-6~1×10-5 level in all facilities. HQs of formaldehyde did exceed 0.1 for all subjects in elementary school.
        4,500원
        17.
        2011.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was to assess the lifetime cancer and non-cancer risk on exposure to volatile organic compounds This study was assessed the lifetime cancer and non-cancer risk of volatile organic compounds (VOCs) exposure in young children at elementary-schools and academies in Korea. The samples were collected at children's facilities (50 elementary-schools and 42 academies) in summer (Aug ~ Sept, 2008), winter (Dec 2008 ~ Feb, 2009) and Spring (Mar ~ Apr, 2009) periods, and analyzed by GC-MSD. We estimated the lifetime excess cancer risks (ECRs) of benzene and the hazard quotients (HQs) of non-carcinogens toluene, ethylbenzene, xylene and styrene. In addition, for carcinogens, the excess cancer risk (ECR) was calculated by considering the process of deciding cancer potency factor (CPF) and age dependent adjust Factor (ADAF) from the data in adults. The average ECRs of benzene for young children were 1×10-7~1×10-9 level in all facilities. HQs of four non-carcinogens did not exceed 1.0 for all subjects in all facilities.
        4,300원
        18.
        2011.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was to assess the lifetime cancer and non-cancer risk on exposure to volatile organic compounds (VOCs) and formaldehyde of worker and user at public facilities in Korea. We measured the concentrations of formaldehyde and VOCs in indoor air at 160 public buildings that 5 kinds of public facilities (30 hotel, 30 fitness center, 25 gosiwon, 30 reading-room and 45 video-room) all over the country. There were estimated the human exposure dose and risks with averages of the using-time and frequency for facility users and office workers, respectively. Carcinogens (benzene and formaldehyde) were estimated the lifetime excess cancer risks (ECRs). Non-carcinogens (toluene, ethylbenzene, xylene, and styrene) were estimated the hazard quotients (HQs). HQs of four non-carcinogens did not exceed 1.0 for all subjects in all facilities. Higher HQs of toluene were observed at the reading-room. The average ECRs of formaldehyde and benzene for facility worker and user were 1×10-4~1×10-6 level in all facilities. The estimated ECRs for reading-room were the highest and the fitness center and gosiwon were the next higher facilities. Because lifetime ECRs of carcinogens exceeded 1×10-4 for facility worker in the most facilities, risk management of formaldehyde and benzene in the facilities was necessary. IAQ guidelines should be determined strictly to prevent occurrence of disease caused by poor IAQ beforehand.
        4,500원
        19.
        2011.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study assessed the health risk of trace elements in indoor children-facilities by multi-pathway measurements (Air, Dust, Wipe, Hand washing). The samples of indoor place were collected at various children's facilities (40 day-care houses, 42 child-care centers, 44 kindergartens, and 42 indoor playgrounds) in summer (Jul~Sep, 2007) and winter (Jan~Feb, 2008) periods, and analyzed by ICP-MS. The lifetime Excess Cancer Risks (ECRs) were estimated for carcinogen trace elements such as As, Cd, Cr and Ni. For carcinogens, the Excess Cancer Risk (ECR) was calculated by considering the process of deciding Cancer Potency Factor (CPF) and Age Dependent Adjust Factor (ADAF) of the data of adults. Both Hazard Quotients (HQs) and Hazard Index (HI) were estimated for the non-carcinogens and children sensitivity trace elements like Cd, Cu, and Cr. The average ECRs for young children were 1×10-10~1×10-6 (50%th percentile) level in all facilities. Non-carcinogens and Children's sensitivity materials did not exceed 1.0 (HQs, HI) for all subjects in all facilities. For trace elements their detection rates through multi-pathways were not high and their risk based on health risk assessment was also observed to be acceptable. In addition, through education on the risk of multi-pathway exposure of trace elements for managers of facilities as well as for users the risk control of exposure of children.
        5,400원
        20.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Domestic studies for identification of causality between children exposure to toxic chemicals, such as arsenic (As) and resulted hazardous effects were not implemented. This study was conducted to probabilistically estimate dietary As intake and health risk assessment for young children and all age-specific populations from the consumption of As-contaminated rice of Korea. Arsenic intakes for young children (1 to 6 years old) from As-contaminated rice were higher than other age-specific groups, based on a dose-per-body weight basis. Based on the current EPA cancer slope factor for As, estimated cancer risks (to the skin cancer) associated with dietary intake of As-contaminated rice for 1 to 2 years old group and 3 to years old group are 1.76 per 10,000 and 3.16 per 10,000, respectively, at the 50th percentile. Based on possible reference levels (0.005 mg/kg/day) for children, mean and 95th percentile value of HQ from rice for young children are very below 1.0, which is a regulatory limit of non-carcinogenic risks for human.
        4,000원
        1 2