        1.
        2024.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to compare six observational methods for assessing arm- and hand-intensive tasks, based on literature review. The comparison was conducted in viewpoints of body regions, force/external load, motion repetition, other factors including static posture, coupling, duration/break, pace, temperature, precision task, and final risk or exposure level. The number of risk factors assessed was more, and assessment procedure was more complex than the observational methods for assessing whole-body postural loads such as Ovako Working Posture Analysis System(OWAS), Rapid Upper Limb Assessment(RULA), and Rapid Entire Body Assessment(REBA). Due to these, the intra- and inter-reliabilities were not high. A past study showed that while Hand Arm Risk Assessment Method(HARM) identified the smallest proportion of the work tasks as high risk, Strain Index(SI) and Quick Exposure Check(QEC) hand/wrist were the most rigorous with classifying most work tasks as high risk. This study showed that depending on the observational technique compared, the evaluation factors, risk or exposure level, and evaluation results were different, making it necessary to select a technique appropriate for the characteristics of the work being assessed.
        4,000원
        2.
        2024.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적: 본 연구는 4가지 다른 프리즘 종류와 크기에 따른 측정 시 발생하는 오차를 수치화하고, 특히 낱개 프리즘을 사용할 때 발생하는 기울임에 의한 오차를 비교하고자 한다. 방법 : 각 4가지 유형의 프리즘 렌즈 수평 프리즘 바(H), 수직 프리즘 바(V), 낱개 프리즘(I), 프레넬 프리즘(F) 에 대해 4개씩 제품을 준비하여 실험을 진행했다. 1 m 거리에서 총 4번 같은 방향으로 측정했으며, H, V, I는 7가 지 프리즘(Δ), 프레넬 프리즘은 3가지 프리즘 크기를 측정하여 발생하는 오차를 비교하였다. 또한 낱개 프리즘의 경우 방향 오차로 인한 오차를 비교하기 위해 1, 3 및 5도를 측정하였고, 수평 방향으로 8가지 프리즘, 수직 방향 으로 6가지 프리즘 크기에 따른 오차를 비교했다. 결과 : 수평 방향에서 프리즘 렌즈를 측정한 결과, H와 I가 가장 오차가 적었으며 두 렌즈 간 차이는 크지 않았 다. F는 12 Δ에서 유의한 오차가 나타났으며(p<0.010), 20 Δ에서 V의 오차가 높아져 F와의 차이가 없었다. 수직 방향에서는 프리즘 크기가 작을수록 H와 V 사이에 차이가 없었으나, 16 및 20 Δ부터 H와 V에서 유의한 오차가 나타났다(p<0.010). I를 수평 및 수직 방향으로 3가지 각도로 기울였을 때, 2 Δ에서는 수평 및 수직 방향 모두에서 차이가 없었다. 그러나 4~20 Δ까지 프리즘 크기가 커질수록 수평 및 수직 방향 모두에서 기울기가 증가함에 따라 유의한 차이가 나타났다(p<0.010). 결론 : 본 연구의 결과에 따르면, 프레넬 프리즘에서 가장 많은 오차가 발생한 반면, 낱개 프리즘에서 가장 적은 오차가 나타났다. 프리즘 바는 수평 및 수직 방향으로 나누어져 있어 사용 목적에 맞게 정확히 사용해야 한다. 프 리즘 크기가 커질수록 측정 각도를 주의해야 하며, 임상에서는 오차가 적은 낱개 프리즘을 사용하는 것을 권장 한다.
        4,200원
        3.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 들어 한옥마을과 같은 전통문화를 즐길 수 있는 장소에서 한복 대여를 통해 남녀노소 누구나 쉽게 한복을 체험할 수 있게 되었다. 또한 한복을 착용하는 데서 그치지 않고 인증샷을 찍어 SNS에 공유함으로써 한복 체험이 선풍적인 인기를 얻게 되었다. 하지만 한옥마을과 같은 특정한 장소에서 할 수 있는 한복 체험을 제외하고는 일상생 활에서 한복의 대중화는 어려운 실정이다. 따라서 한복을 일상복으로 대중화하기 위해서는 한복의 편의성뿐만 아니라 한복에서 느껴지는 감성적인 만족까지 반영하여 한복을 디자인을 하는 것이 중요하다. 본 연구는 선행연구를 통 해 추출한 한복에서 느끼는 소비자의 감성을 표현하기 위한 감성 어휘 28개를 활용하여 한복 유형별로 느껴지는 소비자의 감성을 7점 리커드 척도로 측정하였다. 그리고 한복 유형별로 ‘느껴진다’에 해당하는 5점 이상의 점수를 기록한 감성 어휘와 감성 카테고리를 분석하였다. 또한 한복 유형별로 성별에 따른 감성 카테고리의 평균차이를 검 증하였으며, 그 결과 호감 카테고리에서만 남녀 간의 유의한 차이가 있었다. 마지막으로 한복 유형을 전통 한복(배냇 저고리, 색동저고리, 성인 전통 한복, 전통 혼례복)과 현대 한복(아동 생활 한복, 여자 생활 한복, 남자 생활 한복)으 로 구분하여 감성 카테고리의 평균차이를 검증한 결과 6개의 감성 카테고리인 ‘유쾌감, 심미감, 조화감, 신선감, 호 감, 안정감’에서 전통한복과 현대한복 간의 유의한 차이가 있었다. 본 연구에서 도출한 한복 유형별로 느껴지는 감성 어휘에 대한 분석 결과는 소비자에게 보다 감성적인 만족을 제공하는데 도움이 되리라 기대된다.
        4,300원
        4.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Several analytical measurement techniques have been developed over the years for ammonia (NH3). However, the field monitoring of NH3 still remains a significant challenge owing to the wide range of possible environmental conditions and NH3 concentration. In this regard, it is imperative to ensure the quality control of techniques to measure the NH3 emission levels reliably. A present study was conducted to compare the five analytical methods for the measurement of atmospheric NH3 via validation tests under laboratory and field conditions. The analytical instruments applied in the present study were based on wet chemistry, gas detection tube, electrochemical sensor, photoacoustic spectroscopy, and cavity ring-down spectroscopy. The reproducibility and linearity of all the analyzed methods were observed to be high with the relative standard deviation and coefficient of determination (R2) being 10% and > 0.9, respectively. In the case of wet chemistry and high NH3 concentration, the measured NH3 results were found to be close to the actual standard gas levels. Response times of electrochemical sensor showed faster from the instruments utilized more than one year and the high NH3 concentrations. In the field tests, NH3 concentration showed higher in the manure storage tank compared with the pig-pen. In both cases, the NH3 concentration levels measured by gas detection tube were found to be quite different from that of wet chemistry. It was proposed that such differences in NH3 concentration could arise due to the inherent instrumental characteristics and the variations in air velocity during sampling/measurement. The periodic instrumental maintenance, verification, replicate analyses, and suitable consideration of environmental factors should be considered for a more reliable measurement of NH3 concentration under real field conditions.
        4,300원
        6.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Two experiments were conducted to determine how much sodium in food could be detected using a salinity meter. First, the salinity of mixed solutions of 0 to 6% sugar, 0 to 5% oil, and 0 to 6.4% MSG in a 1% NaCl solution was measured using a salinity meter and a Mohr titration method, and the results were compared with the calculated sodium expectations. As a result, the sodium contents of the sugar solutions and MSG solutions measured using a salinity meter were lower than the expected concentrations at 2% or more and 0.8% or more, respectively (p<0.05). The salinity of the 18 HMR products was measured in the same way, and the results were then compared with the sodium contents of the nutrition facts. The average sodium content of all products measured using the salinity meter and Mohr method was 1.12 times and 1.06 times the sodium content of the nutrition facts, respectively. On the other hand, the differences between the products were significant. The correlation coefficients between the nutrition facts and salinity meter, the nutrition facts and the Mohr method, and the salinity meter and Mohr method were 0.885, 0.920, and 0.950, respectively (p<0.01).
        4,000원
        7.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since the implementation of the Odor Prevention Act in 2005, the number of odor complaints has continuously increased due to the increased interest in the living environment. The current odor control means is a concentrationbased method for the source of odor. That is why there is a difference between the odor sensitivity and the result of the odor measurement in the odor damage area. The government is considering the introduction of the grid method, which is the odor management method of Germany, as the method of odor investigation in the odor damage area in the second comprehensive Odor Prevention Policy (2019-2028). The grid method is receptor-based odor measurement method that investigators use to judge odors in the field, task that expensive and requires substantial manpower and time. To study an odor measurement method that is suitable for domestic conditions, this study compared the correlation between results based on the odor frequency concept grid method around the livestock facilities and the result of ammonia concentration measured by passive air sampler. The correlation coefficient (R) that is between the frequency of odor per spot for the entire odor and the ammonia concentration that was measured by passive air sampler was 0.65 which is relatively good. Among the entire odor detected by the grid method, the correlation coefficient (R) between the odor frequency selected only for livestock odor and the ammonia concentration was significantly increased to 0.80. In addition, the correlation between odor exposure (ECPexist) and the ammonia concentration for the overall odor was 0.81 (linear) and 0.86 (index). If only the livestock odors were selected, the correlation between odor exposure and the ammonia concentration was very high at 0.96 (linear) and 0.95 (index).
        4,000원
        8.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 서로 다른 디자인의 시표를 사용하여 자각적 원거리 수평 주시시차 교정 값을 비교 및 분석해 보고자 하였다. 방법 : 35명의 시각적 불편함(설문지 기준)을 느끼는 대상자를 선정하였다. MKH 차트, 말렛 유닛, 중심융합자 극점이 있는 차트프로젝터 십자시표를 사용하여 원거리 주시시차 교정 값을 측정하고, 주시시차 교정 전후의 최소 입체각을 측정하였다. 결과 : MKH 차트, 말렛 유닛, 중심융합자극점이 있는 차트프로젝터 십자시표에서 자각적으로 측정된 원거리 수평 주시시차 교정 값은 각각 0.99±0.50 △, 0.31±0.30 △, 0.52±0.46 △으로 측정되었고 유의한 차이가 있었다(F=23.002, p=0.000). 주시시차 교정 전 최소입체각은 85.43±54.68″이었다. MKH 차트, 말렛 유닛, 중심 융합자극점이 있는 차트프로젝터 십자시표를 사용한 주시시차 교정 후에 증가된 최소입체각은 각각 58.00±40.2 1″(t=4.280, p=0.000), 75.14±54.09″(t=3.111, p=0.000), 69.14±50.66″(t=2.503, p=0.000)로 측정되었고 유의한 차이가 있었다. 결론 : 시표의 디자인에 따른 주시시차 교정 값에는 유의한 차이가 있었고, 주시시차 교정 후의 최소입체각은 모든 시표에서 유의하게 향상되었다. 본 연구에서는 서로 다른 디자인의 3가지 시표 중 MKH 차트를 통해 주시시차를 교정한 후 최소입체각이 가장 많이 향상되었다.
        4,800원
        9.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the demand of wire quality improvement has been increasing due to the development of the textile market, and the demand for round type flat wire having superior performance compared to the existing reed wire is also increasing greatly. The round wire requires equal spacing and precise alignment of the wire at reed knitting. So, there is a need for a method for measuring the flatness of Reed in real time. In this paper, it is shown how the contact and non - contact methods for the flatness of Reed used in a power loom are easy to measure in real - time process. The contact-type method provides excellent measurement accuracy and precision because it directly touches the object. The non-contact type does not touch the object, so it does not scratch the surface, and the result can be obtained faster than the contact type. Contact type measuring device was used as contact type and laser displacement sensor was used as non - contact type. It was confirmed that the measurement method using the laser displacement sensor (non-contact type) is suitable for the real time process.
        4,000원
        10.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 한국 초등학생의 안축장 분포를 조사하고, 오전과 오후 측정시간에 따른 안축장의 차이를 관찰하였다. 방법 : 단면연구로 서울지역에 거주하는 12~13세(평균 연령: 12.4±0.3세, 여: 17명)의 34명 34안을 대상으로 하였다. 부분결합간섭 측정계를 이용하여 안축장을 측정하였고, 굴절이상도는 개방형 자동굴절력계를 이용하였다. 일일 동안 4시간 간격으로 오전 9시와 오후 1시에 두 번 안축장을 측정하였다. 결과 : 성별에 따른 안축장의 차이는 없었다(AM: 남, 24.24±1.19 mm; 여, 24.04±0.94 mm, p=0.578, PM: 남, 24.29±1.13 mm, 여, 24.18±0.85 mm, p=0.750). 오전과 오후에 측정된 안축장은 유의한 양의 상관성을 보였다(r2=0.949, p<0.001). 안축장은 오전 9시(24.18±1.08 mm)와 오후 1시(24.25±1.00 mm)에 관찰되었다(p=0.709). 그러나 안축장의 차이는 0.07±0.34 mm로 통계적으로 유의한 차이는 없었다. 결론 : 안축장은 전반적으로 오전 보다 오후에 길게 측정 되었지만 측정시간에 따라 통계적으로 유의한 차이는 없었다.
        4,000원
        11.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Charcoal canisters are broadly used for radon detection because of their handiness and short sampling period. Radon detection using charcoal canisters are known to be susceptible to surrounding conditions such as temperature and humidity. Public radon inspectors cannot handle extreme temperature, and the relative humidity can differ in districts due to the use of different types of construction. Thus, if relative humidity can be controlled at the entrance of a charcoal canister, radon inspectors will be able to procure more reliable data. The purpose of this study was to assess the efficiency of existing filters in a charcoal canister and to apply a new type of filter (Super Absorbent Polymers, SAP) that can control the moisture penetrating into the charcoal canister. Based on adequate case studies using the new filter, radon data have shown over 98% close to the reference data irrespective of varying moisture levels. Meanwhile, basic filters showed 88% similarity compared to the reference data, which means that charcoal canisters were affected by moisture. The SAP filter is reasonably inexpensive and once it turns into its gel shape (which, in turn, is saturated by moisture), it can be easily replaced. This filter will not only be able to provide more accurate radon data, but also apply to other gas phase material detections that are sensitive to moisture in the air.
        4,000원
        12.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: The Microsoft Kinect which is a low-cost gaming device has been studied as a promise clinical gait analysis tool having satisfactory reliability and validity. However, its accuracy is only guaranteed when it is properly positioned in front of a subject. Objects: The purpose of this study was to identify the error when the Kinect was positioned at a 45˚ angle to the longitudinal walking plane compare with those when the Kinect was positioned in front of a subject. Methods: Sixteen healthy adults performed two testing sessions consisting of walking toward and 45˚ obliquely the Kinect. Spatiotemporal outcome measures related to stride length, stride time, step length, step time and walking speed were examined. To assess the error between Kinect and 3D motion analysis systems, mean absolute errors (MAE) were determined and compared. Conclusion: Based on our study experience, positioning the Kinect directly in front of the person walking towards it provides the optimal spatiotemporal data. Therefore, we concluded that the Kinect should be placed carefully and adequately in clinical settings.
        4,000원
        13.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적: 우리는 두 종류의 안압계로 정상 범위 안압과 녹내장 쥐 모델의 안압을 측정하여 안압값을 비교하였다. 두 안압계 중 어느 것이 더 쉽고 정확하게 동물 모델의 안압을 측정할 수 있는지 알아보고자 하였다. 방법: 녹내장 눈은 6주령 수컷 Sparque-Dawley (SD) 쥐의 오른쪽 눈 전방에 점탄물질 히알루론산을 주입하여 유도하였으며 정상 대조군으로는 동일 쥐의 좌안을 사용하였다. 안압은 오후 3시경 리바운드 압평 안압계 (Tonolab)와 함입 안압계 (Tonopen® XL)로 측정하였다. 결과: 대조군인 정상 안압 눈의 평균 안압은 토노펜으로 측정 시 10.80 ± 1.03 mmHg, 토노랩으로 측정시 15.10 ± 0.73 mmHg으로 측정되었다. 이 수치들은 통계적으로 유의한 차이는 없었다 (p = .1). 실험군인 녹내장 눈의 평균 안압은 토노펜으로 측정 시 30.20 ± 2.67 mmHg, 토노랩으로 측정 시 37.90 ± 2.73mmHg로 측정되었다. 이 수치들은 통계적으로 유의한 차이는 없었다 (p = .95). 고안압인 녹내장 눈을 두 안압계로 잰 수치들은 강한 양의 상관관계를 지니고 있었다 (r = .904, p < .01). 결론: 이 연구는 두 가지 유형의 안압계를 사용하여 정상 범위 안압과 전방에 점탄물질을 삽입하여 유도한 녹내장 모델의 안압값을 비교한 최초의 연구이다. 토노펜은 안압이 정상범위일 때는 주의해서 사용해야 하며, 토노펜과 토노랩은 안압이 높은 범위일 때는 두 안압계 모두 안정적으로 사용될 수 있다.
        4,000원
        14.
        2018.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Various rheological methods to measure the hardness of instant cooked rice by a texture analyzer were investigated and compared. Specifically, instant white rice samples with a wide range of hardness were subjected to four different rheological tests with disk, cylinder, rod, and cone probe whose results were inter-correlated. All the measurements demonstrated that the hardness of instant rice was reduced with increasing moisture content and showed negatively linear relationships. Out of the four tests applied in this study, the highest coefficient of correlation (R2 = 0.9268) was observed distinctly in the cone probe test, where both compressive and shear forces can be applied to deform individual rice grains. However, the cylinder probe test had the lowest coefficient of correlation (R2 = 0.7247) because it may be ineffective in causing direct deformation of individual rice grains. Furthermore, when the hardness values (N) were converted to stress (Pa), highly linear correlations (R2 ≈ 0.99) were observed between the tests with similar probe geometry and force application.
        4,000원
        15.
        2018.04 구독 인증기관·개인회원 무료
        콩나물(Glycine max L. Merrill)은 우리 고유의 전통식품으로서 무침, 국, 찌개, 밥 등 다양한 방법으로 이용되고 있으며 최근에는 편리를 추구하는 바쁜 현대인들을 위하여 콩나물의 반조리식품화 또는 가공식품화의 형태로 이용성이 증가되고 있다. 이에 따라 소비자의 기호에 맞는 고품질 콩나물의 생산을 위하여 콩나물 콩의 생육특성, 발아특성에 대한 연구가 진행되어 왔으나 생 콩나물의 조리 후 조직감 특성에 관한 연구는 부족한 실정이다. 특히 콩나물의 조직감 측정 시의 사용하는 프르브와 측정법에 따라 가공처리에 따른 조직감의 유의차가 다르게 나타나므로 가열처리에 따른 콩나물의 조직감의 변화를 수치적으로 평가하기가 어렵다. 이와 같이 가열처리에 따른 콩나물 조직감의 변화를 객관적인 방법으로 평가하기 위하여 본연구에서는 콩나물은 파우치에 물과 함께 포장한 것과 진공포장 한 것을 84 ℃에서 20 분간 가열처리 하여 실린더형과 칼날형의 프로브를 이용하여 조직감 특성을 확인하였다. 콩나물 머리와 줄기의 조직감 특성은 각각 deformation 30%와 60%의 조건일 때 test speed 0.5 mm/s 에서 진행하였으며, 부정형인 콩나물의 머리를 고려하기 위하여 engineering stress와 true stress를 비교하였다. 콩나물 머리의 크기는 버니어 캘리퍼스로 측정하여 deformation 이전 콩나물의 전체 높이 및 긴 반지름, 짧은 반지름을 기준으로 30% deformation 일 때 해당하는 변수를 이용하였다. 가열처리 방법에 따른 콩나물 머리의 조직감은 실린더형 프로브로 측정 시 유의적 차이가 없었으나 칼날형 프로브를 이용하여 일정한 두께로 조직감을 측정하였을 때 유의적 차이를 확인하였다(p<0.05). 또한 콩나물의 줄기도 가열처리 방법에 따라 칼날형 프로브로 측정시 유의적 차이가 있는 결과값을 확인하였다. 이에 따라 칼날형 프로브를 이용한 가열처리 방법에 따른 콩나물 머리의 engineering stress 결과 값은 유의적 차이가 없었으며, 30% deformation 시에 해당하는 변수를 통하여 도출한 콩나물 머리의 면적이 고려된 true stress 결과 값은 가열처리 방법에 따라 각각 89.08 g ± 10.03, 68.16 g ± 5.93으로 유의적 차이를 보였다. 그리고 콩나물의 줄기는 engineering stress와 true stress 결과 값 모두에서 유의적 차이를 확인하였으며, 두 측정법 간에는 유의차(p<0.05)가 없음을 확인하였다. 따라서 콩나물의 머리와 줄기 모두 칼날형 프로브를 이용하는 것이 가열처리에 따른 콩나물의 특성을 유의미하게 판별할 수 있는 방법이 될 수 있음을 확인하였다.
        16.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Rivers continuously transport terrestrial organic carbon matter to the estuary and the ocean, and they play a critical role in productivity and biodiversity in the marine ecosystem as well as the global carbon cycle. The amount of terrestrial organic carbon transporting from the rivers to ocean is an essential piece of information, not only for the marine ecosystem management but also the carbon budget within catchment. However, this phenomenon is still not well understood. Most large rivers in Korea have a well-established national monitoring system of the river flow and the TOC (Total Organic Carbon) concentration from the mountain to the river mouth, which are fundamental for estimating the amount of the TOC flux. We estimated the flux of the total terrestrial organic carbon of five large rivers which flow out to the Yellow Sea, using the data of the national monitoring system (the monthly mean TOC concentration and the monthly runoff of river flow). We quantified the annual TOC flux of the five rivers, showing their results in the following order: the Han River (18.0×109 gC yr-1)>>Geum River (5.9×109 gC yr-1)>Yeongsan River (2.6×109 gC yr-1)>Sumjin River (2.0×109 gC yr-1)>>Tamjin River (0.2×109 gC yr-1). The amount of the Han River, which is the highest in the Korean rivers, corresponds to be 4% of the annual total TOC flux of in the Yellow River, and moreover, to be 0.6% of Yangtze River.
        4,000원
        17.
        2017.11 구독 인증기관·개인회원 무료
        목적: 중등도 근시의 초기성인에서 자각적 굴검검사와 개방형, 내부형 자동굴절력계에 의한 측정값을 비교하여 자동굴절력계의 성능과 정확도를 평가하고자 하였다. 방법: 대상자는 만 18세 이상 ~ 20세 이하(평균 18.94±0.54세)로 중등도 근시(–3.00D≤ S.E.<-7.00D) 이상의 초기성인 36안(남자 12명, 여자 6명)을 검사하였다. 자각식 굴절검사는 수동포롭터 BR-7(Shin-nippon)으로 측정하였고, 자동굴절검사는 개방형 자동굴절력계 Nvision K-5001(Shin-nippon)과 내부형 자동굴절력계 KR-800(Topcon)으로 3회 반복 측정하여 평균 값을 사용하였다. 측정값은 구면굴절력과 실린더굴절력, 축으로 표기하고 다시 Power vector 성분으로 SE(=Shp+Cyl/2), J0(=-Cyl/2․cos(2․Ax)), J45(=-Cyl/2․sin(2․Ax))로 나타내어 Paired T-tset와 Pearson 상관계수를 산출하였다. 통계처리는 SPSS 13.0을 사용하였고, p<0.05인 경 우를 통계적으로 유의하다고 판단하였다. 결과: 자각적 굴절검사와 개방형, 내부형 자동굴절력계에 의한 SE는 –4.37±1.04D, -4.50±1.28D, -4.67±1.40D이고 J0는 –0.32±0.51D, 0.01±0.52D, -0.02±0.62D 그리고 J45 는 0.11±0.37D, 0.24±0.62D, 0.09±0.54D로 나타났다. 자각적 굴절검사와 개방형 자동굴절력계에 의한 상관관계는 SE 성분에서 관계식(상관계수) y=-1.01x+0.75(r=0.92, p=0.00), J0 성분은 y=-0.32x+0.13(r=0.14, p=0.43), J45 성분은 y=0.09x+0.07(r=0.12, p=0.47)이고 내부형 자동굴절력계는 SE 성분이 y=-0.95x+0.73(r=0.98, p=0.00), J0 성분은 y=-0.32x+0.17(r=0.21, p=0.22) 그리고 J45 성분은 y=0.10x+0.05(r=0.08, p=0.65)였다. 연속 변수 비교는 자각적 굴절검사값을 기준으로 개방형 자동굴절력계와 차이값에서 SE, J0, J45 성분이 각각 0.13±0.53(p=0.17), -0.33±0.68(p=0.01), -0.13±0.68(p=0.26)로 J0 성분은 유의한 차이를 보였지만 SE, J45 성분은 차이가 없었다. 내부형 자동굴절력계는 SE, J0, J45 성분이 각각 0.30±0.42(p=0.00), -0.30±0.71(p=0.02), 0.02±0.63(p=0.88)로 J45 성분은 차이가 없지만 SE, J0, 성분은 유의한 차이를 나타났다. 결론: 제시된 분석자료는 임상에서 자동굴절력계를 이용하여 굴절이상을 교정하는 안경사에게 기기의 특성을 이해하는데 도움이 될 것으로 사료된다.
        18.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The gas sensor sensitivity value of three methods (simple application method, vaporization method, and chamber method) were compared in order to establish a method for the measurement of liquid odor substances. In order to select the representative sensors from among the 16 sensors constituting the gas sensor array, cluster analysis, regression analysis, and correlation analysis were performed. Sensors with excellent correlation in terms of reactivity were selected as representative sensors of each measurement method. As a result, it was shown that the reactivity and the correlation increased in the order of simple application method < vaporization method < chamber method. Through a variance analysis using the sensitivity values of selected representative sensors, it was shown that the simple application method had statistical significance at the level of 99.9% (p<0.001) in three of the representative sensors in four clustering groups. The vaporization method and the chamber method showed statistical significance at a level of 99.9% (p<0.001) for all representative sensors in each clustering group. If the reactivity were improved by controlling the sensitivity of the sensor, the simple application method and vaporization method could also be used as a method of measuring the liquid material with gas sensor array.
        4,000원
        19.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적: 정점간거리 증가에 따른 근시-외사위의 원/근거리 사위 측정값의 변화를 분석하고 양안시 검사의 기본 자료를 얻기 위해 실시되었다. 방 법: 시험테와 시험렌즈를 사용하여 외사위이면서 근시인 20명을 대상으로 Modified thorington(MT) 시표, Howell card(HC), Maddox rod(MR)를 사용하여 원/근거리 사위 값을 측정하였다. 사위 측정값은 정 점간거리 12 mm를 기준으로 하여 5 mm, 10 mm, 15 mm 정점간거리를 증가시킨 상태에서 측정하였다. 결 과: 정점간거리 5 mm, 10 mm, 15 mm 증가 시 원/근거리 수평사위 측정값 평균변화는 MT(원거리)에 서 각각 0.09±0.12△, 0.20±0.10△, 0.31±0.11△(F=20.07, p=0.00), MT(근거리)에서 0.09±0.12△, 0.10±0.15△, 0.21±0.20△(F=3.62 p=0.03), HC(원거리)에서 각각 0.06±0.11△, 0.14±0.13△, 0.26±0.19△(F=9.48, p=0.00), HC(근거리)에서는 0.06±0.11△, 0.09±0.12△, 0.19±0.18△(F=4.42, p=0.02), MR(원거리)에서 각각 0.04±0.09, 0.10±0.13, 0.23±0.16△(F=10.97, p=0.00), MR(근거리)에서 는 0.03±0.08△, 0.05±0.10△, 0.11±0.13△(F=3.72, p=0.03)이었고 통계적으로 유의한 차이가 있었다. 결 론: 근시이면서 외사위의 사위 값 측정에서 정점간거리 증가 시 통계적으로 유의한 원/근거리 외사위 값의 감소가 나타났고, 원거리에서 근거리보다 더 큰 변화량이 나타났다. 그 이유는 원거리에서는 정점간거 리 증가에 따른 구면렌즈의 편심을 통해 기저외방(BO)의 프리즘 효과가 유발되었고, 근거리에서는 정점간거 리 증가에 따른 구면렌즈 편심을 통해 유발된 기저내방(BI)의 프리즘 효과 외에 추가적인 근거리 외사위가 유 발되기 때문이다. 따라서 시험테를 사용하여 양안시 검사를 하는 경우 정점간거리를 정확하게 유지해야 하 고, 시험테가 전방으로 이동하지 않도록 주의가 필요한 것으로 사료된다
        4,000원